NRPP RMI flashcards
NRPP RMI · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Radon-222 half-life
- Radon-222 has a half-life of 3.82 days and decays by alpha emission into polonium-218, beginning the short-lived progeny chain that produces the alpha dose in the lung.
- Working level definition
- One working level equals any combination of short-lived radon progeny that releases 1.3 x 10^5 MeV of potential alpha energy per liter of air, equivalent to 100 pCi/L of radon at full equilibrium.
- EPA action level
- The U.S. EPA action level for indoor radon is 4 pCi/L in homes and in schools and large buildings; follow-up testing is required at or above this level.
- Closed-building conditions
- Windows and doors closed except for normal entry and exit, no whole-house or window fans running, and normal HVAC operation, maintained for at least 12 hours before a short-term test begins.
- Minimum short-term test duration
- A short-term radon test must last at least 48 hours, with closed-building conditions maintained for 12 hours before the test starts and throughout the exposure period.
- Device placement height
- Place radon devices at least 20 inches (50 cm) above the floor, 12 inches (30 cm) from exterior walls, and 4 inches (10 cm) from other objects to sample representative breathing-zone air.
- Duplicate measurement purpose
- Duplicate devices deployed side by side assess measurement precision; the relative percent difference between paired results should typically fall within 25% for charcoal and 20% for alpha-track detectors.
- Blank device purpose
- An undeployed device analyzed alongside field samples detects detector background and contamination; blank results should remain below the device's lower limit of detection.
- Spike test definition
- A spike is a device exposed to a known radon concentration in a chamber; results should fall within plus or minus 25% of the known value to confirm measurement accuracy.
- Equilibrium ratio
- The equilibrium ratio is the measured progeny concentration divided by the radon concentration that would exist at full equilibrium; typical indoor values range from 0.3 to 0.7.
- Lower limit of detection
- The LLD is the lowest radon concentration a device can reliably measure; results below it are reported as less than that value rather than as zero.
- Charcoal adsorption device
- A passive short-term detector exposed for 2 to 7 days, then analyzed by gamma spectroscopy or liquid scintillation; its response is sensitive to temperature and humidity.
- Alpha-track detector
- A passive long-term detector using plastic film that records alpha tracks, which are counted after chemical etching; exposure typically runs 1 to 12 months and humidity has little effect.
- Electret ion chamber
- A passive detector whose charged electret loses voltage in proportion to radon exposure; voltage is read before and after deployment to calculate the average concentration.
- Continuous radon monitor
- An active instrument that records hourly radon concentrations, detects tampering and unusual conditions, and requires annual calibration plus a daily function check.
- Post-mitigation test timing
- A post-mitigation test is conducted at least 24 hours after system start-up and within 30 days of installation, using a minimum 48-hour exposure under closed-building conditions.
- Sub-slab depressurization
- The most common mitigation method: a fan draws soil gas from beneath the slab and vents it above the roof, creating a negative pressure field under the foundation.
- Stack effect
- Warm indoor air rising and escaping through upper floors creates negative pressure in lower levels, drawing soil gas through foundation openings; the effect peaks in winter.
- Radon entry routes
- Soil gas enters through foundation cracks, sump pits, floor drains, and gaps around pipes, driven by the stack effect, wind, and mechanical exhaust depressurization.
- Two-test averaging rule
- When two short-term tests are performed, their average determines the mitigation decision; if results differ by more than a factor of two, a third or long-term test is advised.
- Real-estate follow-up rule
- If the first short-term real-estate test is 4 pCi/L or higher, a second short-term test is conducted immediately and the average of the two guides the mitigation decision.
- Radon health risk ranking
- Radon is the second leading cause of lung cancer after smoking and the leading cause among non-smokers; the EPA estimates about 21,000 U.S. lung cancer deaths yearly are radon-related.
- Smoking synergy
- Tobacco smoke and radon exposure act synergistically, so smokers exposed to elevated radon face a far higher lung cancer risk than non-smokers at the same concentration.
- Chain of custody record
- Documentation of device serial numbers, deployment and retrieval dates and times, location, and handler names, kept so samples reach the lab within the device hold time.
- CRM calibration interval
- Continuous radon monitors are calibrated at least annually against a known radon source or a calibrated reference monitor, with the calibration factor documented.
- State regulatory authority
- Several states impose their own radon certification, testing, and reporting rules that may be stricter than EPA protocols; the professional follows the rules of the state where testing occurs.
- Conflict of interest disclosure
- A measurement professional must disclose business relationships with mitigation contractors and must not condition test results on the sale of mitigation services.
- Record retention period
- Test records, QA results, and calibration records are retained for at least three years, or longer if the certification program or state regulation requires it.
- Working level formula
- Working level equals radon concentration in pCi/L multiplied by the equilibrium ratio and divided by 100, linking measured radon gas to progeny alpha energy.
- Unit conversion pCi to Bq
- One picocurie per liter equals 37 becquerels per cubic meter; converting between the two units is required when reporting to clients using SI units.
- Interference invalidation
- If occupants open windows or run exhaust fans during a test, the result may not represent closed-building conditions; the interference is documented and retesting is considered.
- Proficiency testing requirement
- Certified measurement professionals participate in their program's proficiency testing and must maintain a passing score to keep device-specific certification active.