NRPP RMS · Get comfortable with the vocabulary.

Working Level (WL)

A unit of radon decay product concentration equal to any combination of short-lived radon progeny that releases 1.3 × 10^5 MeV of alpha energy per liter of air. Used as the basis for action levels.

Related: Working Level Month (WLM), Equilibrium Ratio
Working Level Month (WLM)

A cumulative exposure unit representing exposure to one Working Level for 170 hours, roughly one occupational month. Used to express lifetime or annual occupational radon progeny exposure.

Related: Working Level (WL)
Picocurie per Liter (pCi/L)

The common U.S. unit of radon gas concentration, meaning trillionths of a curie per liter of air. One picocurie equals 2.22 nuclear transformations per minute.

Related: Becquerel per Cubic Meter (Bq/m³), Action Level
Becquerel per Cubic Meter (Bq/m³)

The SI unit of radon activity concentration, equal to one nuclear transformation per second in a cubic meter of air. One pCi/L equals 37 Bq/m³.

Related: Picocurie per Liter (pCi/L)
Action Level

The radon concentration at which mitigation or further evaluation is recommended. In the U.S. the commonly cited level is 4 pCi/L for long-term occupied spaces.

Related: Picocurie per Liter (pCi/L), EPA Action Level
EPA Action Level

The U.S. Environmental Protection Agency's recommended threshold of 4 pCi/L for indoor radon, above which mitigation is advised. It is a guidance level, not a mandatory federal standard.

Related: Action Level
Short-Term Test

A radon measurement conducted for a period of 2 to 90 days, typically using charcoal or electret devices. Used for screening and real-estate transactions but more subject to seasonal variation.

Related: Long-Term Test, Closed-House Conditions
Long-Term Test

A radon measurement lasting more than 90 days, usually with alpha-track or electret devices. Provides a more representative annual average because it spans seasonal and weather variation.

Related: Short-Term Test, Alpha-Track Detector
Closed-House Conditions

Measurement conditions requiring exterior doors and windows kept closed, typically 12 hours before and throughout a short-term test, with normal heating or cooling operating. Prevents dilution by outdoor air.

Related: Short-Term Test, Test Placement
Test Placement

The selection of measurement locations within a building, generally the lowest livable level and occupied rooms, away from exterior walls, drafts, and moisture sources. Placement strongly affects result validity.

Related: Closed-House Conditions, Lowest Livable Level
Lowest Livable Level

The lowest floor of a building that is suitable for occupancy, such as a basement with finished living space or a slab-on-grade floor. Measurements are typically made here because radon concentrates at lower levels.

Related: Test Placement
Alpha-Track Detector

A passive radon measurement device using a plastic film that records alpha particle tracks from radon decay. Suitable for long-term tests and less affected by short-term fluctuations.

Related: Long-Term Test, Electret Ion Chamber
Electret Ion Chamber

A passive radon device in which an electrically charged electret is discharged by ionizing radiation; the voltage drop indicates radon concentration. Can be used for short- or long-term measurements.

Related: Alpha-Track Detector
Charcoal Adsorption Detector

A passive short-term radon device in which activated charcoal adsorbs radon gas for later laboratory counting. Typically deployed for 2 to 7 days and sensitive to temperature and humidity.

Related: Short-Term Test, Continuous Radon Monitor
Continuous Radon Monitor (CRM)

An electronic instrument that measures radon concentration at intervals, such as hourly, and stores time-series data. Useful for detecting tampering and short-term variation during real-estate tests.

Related: Charcoal Adsorption Detector, Spike Test
Equilibrium Ratio

The ratio of actual radon decay product concentration to the concentration expected at full equilibrium with the parent radon gas. Values below 1.0 indicate incomplete equilibrium, common indoors.

Related: Working Level (WL)
Radon Decay Products (Progeny)

Short-lived radioactive daughters of radon, such as polonium-218 and polonium-214, that emit alpha particles. They are the primary source of radiation dose to lung tissue.

Related: Working Level (WL), Equilibrium Ratio
Quality Assurance Project Plan (QAPP)

A written document describing measurement objectives, methods, calibration, and quality control procedures for a radon measurement project. Required for many regulated or contract measurement programs.

Related: Spike Test, Duplicate Measurement
Spike Test

A quality control check in which a device is exposed to a known radon concentration and its reported result is compared with the known value. Evaluates measurement bias and accuracy.

Related: Duplicate Measurement, Quality Assurance Project Plan (QAPP)
Duplicate Measurement

Two devices deployed side by side at the same location for the same period to assess precision. Differences between results reveal random error in the measurement process.

Related: Spike Test, Quality Assurance Project Plan (QAPP)
Cross-Interference

The effect of non-radon factors, such as humidity, temperature, or other gases, on a detector's response. Addressed through calibration and device-specific correction factors.

Related: Spike Test
Chain of Custody

Documentation tracking a measurement device from deployment through retrieval and laboratory analysis, recording who handled it and when. Prevents sample mix-ups and supports result defensibility.

Related: Quality Assurance Project Plan (QAPP)
Soil Gas

Air contained in pore spaces of soil and rock, which can carry radon from uranium-bearing material toward a building foundation. Its radon concentration and permeability drive entry potential.

Related: Soil Gas Permeability, Soil Gas Retarder
Soil Gas Permeability

The ease with which gas flows through soil, governed by grain size, compaction, and moisture. Higher permeability allows more radon-laden soil gas to move toward and into a building.

Related: Soil Gas, Pressure Field Extension (PFE)
Pressure Field Extension (PFE)

The spatial reach of the sub-slab pressure difference created by a mitigation fan. Adequate PFE means the vacuum extends under the slab to intercept soil gas before it enters.

Related: Sub-Slab Depressurization (SSD), Communication Test
Sub-Slab Depressurization (SSD)

A mitigation technique that uses a fan and piping to draw soil gas from beneath a slab and vent it outdoors, lowering pressure below the slab relative to the building interior.

Related: Pressure Field Extension (PFE), Radon Mitigation System
Radon Mitigation System

An engineered set of components, including suction points, piping, and a fan, designed to reduce indoor radon concentrations. Must be designed, installed, and labeled per applicable standards.

Related: Sub-Slab Depressurization (SSD), System Label
Suction Point

The location where a mitigation system extracts soil gas, such as a pit beneath a slab or a sump. Its placement and sealing determine how effectively vacuum spreads under the slab.

Related: Sub-Slab Depressurization (SSD), Sump Pit
Sump Pit

A pit at the low point of a basement floor that collects water. It can serve as a suction point if properly sealed, or act as a radon entry route if left open.

Related: Suction Point, Sealing
Sealing

Closing openings such as cracks, joints, sumps, and penetrations to limit soil gas entry. Sealing alone rarely reduces radon enough but improves the performance of depressurization systems.

Related: Sump Pit, Radon Mitigation System
Communication Test

A diagnostic test that measures how easily air moves through sub-slab material, often by applying suction and observing pressure or flow. Informs suction point placement and fan sizing.

Related: Pressure Field Extension (PFE), Suction Point
Manometer

A pressure gauge, often a U-tube or digital device, used to verify that a mitigation system is developing vacuum and that the fan is operating. Provides a visual system-performance indicator.

Related: System Label, Pressure Field Extension (PFE)
System Label

A durable notice placed on a mitigation system identifying the installer, installation date, and service contact, and warning occupants not to disable the system. Required by mitigation standards.

Related: Radon Mitigation System, Manometer
Radon Fan

The blower that draws soil gas through the mitigation piping and discharges it above the roof. Must be rated for the application and located to avoid discharging near windows or air intakes.

Related: Discharge Point, Sub-Slab Depressurization (SSD)
Discharge Point

The outdoor location where a mitigation system vents soil gas, typically above the roof line and away from openings. Proper placement prevents re-entry of radon into the building.

Related: Radon Fan
Soil Gas Retarder

A membrane or barrier installed over exposed soil in crawl spaces or beneath slabs to restrict soil gas movement into the building. Must be sealed at edges and penetrations to be effective.

Related: Crawl Space Depressurization, Sealing
Crawl Space Depressurization

A mitigation approach that draws air from a sealed crawl space and vents it outdoors, preventing soil gas from moving into the living space above. Requires a sealed barrier over the soil.

Related: Soil Gas Retarder
Post-Mitigation Test

A radon measurement performed after a mitigation system is installed to confirm the reduction meets the target. Should follow the same closed-house and placement protocols as the original test.

Related: Radon Mitigation System, Closed-House Conditions