NRPP RMS key terms
NRPP RMS · Get comfortable with the vocabulary.
- Working Level (WL)
- Related: Working Level Month (WLM), Equilibrium Ratio
A unit of radon decay product concentration equal to any combination of short-lived radon progeny that releases 1.3 × 10^5 MeV of alpha energy per liter of air. Used as the basis for action levels.
- Working Level Month (WLM)
- Related: Working Level (WL)
A cumulative exposure unit representing exposure to one Working Level for 170 hours, roughly one occupational month. Used to express lifetime or annual occupational radon progeny exposure.
- Picocurie per Liter (pCi/L)
- Related: Becquerel per Cubic Meter (Bq/m³), Action Level
The common U.S. unit of radon gas concentration, meaning trillionths of a curie per liter of air. One picocurie equals 2.22 nuclear transformations per minute.
- Becquerel per Cubic Meter (Bq/m³)
- Related: Picocurie per Liter (pCi/L)
The SI unit of radon activity concentration, equal to one nuclear transformation per second in a cubic meter of air. One pCi/L equals 37 Bq/m³.
- Action Level
- Related: Picocurie per Liter (pCi/L), EPA Action Level
The radon concentration at which mitigation or further evaluation is recommended. In the U.S. the commonly cited level is 4 pCi/L for long-term occupied spaces.
- EPA Action Level
- Related: Action Level
The U.S. Environmental Protection Agency's recommended threshold of 4 pCi/L for indoor radon, above which mitigation is advised. It is a guidance level, not a mandatory federal standard.
- Short-Term Test
- Related: Long-Term Test, Closed-House Conditions
A radon measurement conducted for a period of 2 to 90 days, typically using charcoal or electret devices. Used for screening and real-estate transactions but more subject to seasonal variation.
- Long-Term Test
- Related: Short-Term Test, Alpha-Track Detector
A radon measurement lasting more than 90 days, usually with alpha-track or electret devices. Provides a more representative annual average because it spans seasonal and weather variation.
- Closed-House Conditions
- Related: Short-Term Test, Test Placement
Measurement conditions requiring exterior doors and windows kept closed, typically 12 hours before and throughout a short-term test, with normal heating or cooling operating. Prevents dilution by outdoor air.
- Test Placement
- Related: Closed-House Conditions, Lowest Livable Level
The selection of measurement locations within a building, generally the lowest livable level and occupied rooms, away from exterior walls, drafts, and moisture sources. Placement strongly affects result validity.
- Lowest Livable Level
- Related: Test Placement
The lowest floor of a building that is suitable for occupancy, such as a basement with finished living space or a slab-on-grade floor. Measurements are typically made here because radon concentrates at lower levels.
- Alpha-Track Detector
- Related: Long-Term Test, Electret Ion Chamber
A passive radon measurement device using a plastic film that records alpha particle tracks from radon decay. Suitable for long-term tests and less affected by short-term fluctuations.
- Electret Ion Chamber
- Related: Alpha-Track Detector
A passive radon device in which an electrically charged electret is discharged by ionizing radiation; the voltage drop indicates radon concentration. Can be used for short- or long-term measurements.
- Charcoal Adsorption Detector
- Related: Short-Term Test, Continuous Radon Monitor
A passive short-term radon device in which activated charcoal adsorbs radon gas for later laboratory counting. Typically deployed for 2 to 7 days and sensitive to temperature and humidity.
- Continuous Radon Monitor (CRM)
- Related: Charcoal Adsorption Detector, Spike Test
An electronic instrument that measures radon concentration at intervals, such as hourly, and stores time-series data. Useful for detecting tampering and short-term variation during real-estate tests.
- Equilibrium Ratio
- Related: Working Level (WL)
The ratio of actual radon decay product concentration to the concentration expected at full equilibrium with the parent radon gas. Values below 1.0 indicate incomplete equilibrium, common indoors.
- Radon Decay Products (Progeny)
- Related: Working Level (WL), Equilibrium Ratio
Short-lived radioactive daughters of radon, such as polonium-218 and polonium-214, that emit alpha particles. They are the primary source of radiation dose to lung tissue.
- Quality Assurance Project Plan (QAPP)
- Related: Spike Test, Duplicate Measurement
A written document describing measurement objectives, methods, calibration, and quality control procedures for a radon measurement project. Required for many regulated or contract measurement programs.
- Spike Test
- Related: Duplicate Measurement, Quality Assurance Project Plan (QAPP)
A quality control check in which a device is exposed to a known radon concentration and its reported result is compared with the known value. Evaluates measurement bias and accuracy.
- Duplicate Measurement
- Related: Spike Test, Quality Assurance Project Plan (QAPP)
Two devices deployed side by side at the same location for the same period to assess precision. Differences between results reveal random error in the measurement process.
- Cross-Interference
- Related: Spike Test
The effect of non-radon factors, such as humidity, temperature, or other gases, on a detector's response. Addressed through calibration and device-specific correction factors.
- Chain of Custody
- Related: Quality Assurance Project Plan (QAPP)
Documentation tracking a measurement device from deployment through retrieval and laboratory analysis, recording who handled it and when. Prevents sample mix-ups and supports result defensibility.
- Soil Gas
- Related: Soil Gas Permeability, Soil Gas Retarder
Air contained in pore spaces of soil and rock, which can carry radon from uranium-bearing material toward a building foundation. Its radon concentration and permeability drive entry potential.
- Soil Gas Permeability
- Related: Soil Gas, Pressure Field Extension (PFE)
The ease with which gas flows through soil, governed by grain size, compaction, and moisture. Higher permeability allows more radon-laden soil gas to move toward and into a building.
- Pressure Field Extension (PFE)
- Related: Sub-Slab Depressurization (SSD), Communication Test
The spatial reach of the sub-slab pressure difference created by a mitigation fan. Adequate PFE means the vacuum extends under the slab to intercept soil gas before it enters.
- Sub-Slab Depressurization (SSD)
- Related: Pressure Field Extension (PFE), Radon Mitigation System
A mitigation technique that uses a fan and piping to draw soil gas from beneath a slab and vent it outdoors, lowering pressure below the slab relative to the building interior.
- Radon Mitigation System
- Related: Sub-Slab Depressurization (SSD), System Label
An engineered set of components, including suction points, piping, and a fan, designed to reduce indoor radon concentrations. Must be designed, installed, and labeled per applicable standards.
- Suction Point
- Related: Sub-Slab Depressurization (SSD), Sump Pit
The location where a mitigation system extracts soil gas, such as a pit beneath a slab or a sump. Its placement and sealing determine how effectively vacuum spreads under the slab.
- Sump Pit
- Related: Suction Point, Sealing
A pit at the low point of a basement floor that collects water. It can serve as a suction point if properly sealed, or act as a radon entry route if left open.
- Sealing
- Related: Sump Pit, Radon Mitigation System
Closing openings such as cracks, joints, sumps, and penetrations to limit soil gas entry. Sealing alone rarely reduces radon enough but improves the performance of depressurization systems.
- Communication Test
- Related: Pressure Field Extension (PFE), Suction Point
A diagnostic test that measures how easily air moves through sub-slab material, often by applying suction and observing pressure or flow. Informs suction point placement and fan sizing.
- Manometer
- Related: System Label, Pressure Field Extension (PFE)
A pressure gauge, often a U-tube or digital device, used to verify that a mitigation system is developing vacuum and that the fan is operating. Provides a visual system-performance indicator.
- System Label
- Related: Radon Mitigation System, Manometer
A durable notice placed on a mitigation system identifying the installer, installation date, and service contact, and warning occupants not to disable the system. Required by mitigation standards.
- Radon Fan
- Related: Discharge Point, Sub-Slab Depressurization (SSD)
The blower that draws soil gas through the mitigation piping and discharges it above the roof. Must be rated for the application and located to avoid discharging near windows or air intakes.
- Discharge Point
- Related: Radon Fan
The outdoor location where a mitigation system vents soil gas, typically above the roof line and away from openings. Proper placement prevents re-entry of radon into the building.
- Soil Gas Retarder
- Related: Crawl Space Depressurization, Sealing
A membrane or barrier installed over exposed soil in crawl spaces or beneath slabs to restrict soil gas movement into the building. Must be sealed at edges and penetrations to be effective.
- Crawl Space Depressurization
- Related: Soil Gas Retarder
A mitigation approach that draws air from a sealed crawl space and vents it outdoors, preventing soil gas from moving into the living space above. Requires a sealed barrier over the soil.
- Post-Mitigation Test
- Related: Radon Mitigation System, Closed-House Conditions
A radon measurement performed after a mitigation system is installed to confirm the reduction meets the target. Should follow the same closed-house and placement protocols as the original test.