NRPP RMS study materials
NRPP RMS study resources

NRPP RMS study plan

NRPP RMS · Give each week a clear focus.

8 weeks · About 6 hours per week

Week 1

Radon Measurement (measurement professional scope, per NRPP Measurement Professional Exam and applicable ANSI/AARST measurement standards)

  • Map the Domain 1 blueprint into a one-page checklist of measurement tasks: device placement, closed-building conditions, deployment and retrieval, chain of custody, and reporting.

  • Define and recite the core physics vocabulary (radon, radon decay products, half-life, picocurie per liter, working level, equilibrium ratio) without notes.

  • Distinguish the device families (charcoal canister, alpha-track, electret ion chamber, continuous radon monitor, charcoal liquid scintillation) by deployment duration, sensitivity, and interference risks.

  • Walk through the closed-building protocol steps and state why each step exists before any device is placed.

Your checkpoint

A one-page comparison table of five measurement device types with deployment duration, typical use case, and one failure mode each.

Week 2

Radon Measurement (measurement professional scope, per NRPP Measurement Professional Exam and applicable ANSI/AARST measurement standards)

  • Sequence a full measurement event from client call to final report, listing every document generated at each step.

  • Apply the correct test-duration choice (short-term versus long-term) to five written client scenarios and justify each choice.

  • Identify quality-assurance components: duplicates, blanks, spikes, cross-checks, and calibration records, and state the acceptance criterion for each.

  • Interpret a sample result set against the applicable action level and write the client recommendation in plain language.

Your checkpoint

A written 48-hour test plan for a two-story home with a basement, including placement sketch described in words, QA samples, and the report outline.

Week 3

Radon Measurement (measurement professional scope, per NRPP Measurement Professional Exam and applicable ANSI/AARST measurement standards)

  • Diagnose five written measurement errors (device moved, windows opened, HVAC running, device retrieved late, improper placement height) and state the corrective action for each.

  • Explain the difference between measurement and mitigation professional responsibilities at the handoff point.

  • Practice the client-communication script for delivering an elevated result, including what not to promise.

  • Complete a timed 25-question Domain 1 self-quiz and log every missed concept with a one-line correction.

Your checkpoint

An error log of at least 15 missed or uncertain Domain 1 concepts, each rewritten as a correct one-sentence rule.

Week 4

Radon Measurement (measurement professional scope, per NRPP Measurement Professional Exam and applicable ANSI/AARST measurement standards) & Radon Mitigation and Soil Gas (mitigation specialist scope, per NRPP Mitigation Specialist Exams and applicable ANSI/AARST mitigation standards)

  • Define soil gas and pressure-field concepts: soil gas concentration, permeability, pressure differential, stack effect, and communication between soil and building.

  • Explain the driving forces that move soil gas into a building and rank them by typical influence.

  • Compare sub-slab depressurization, sub-membrane depressurization, and drain-tile/block-wall depressurization by site condition.

  • Describe the diagnostic steps before system design and what each diagnostic measurement tells the designer.

Your checkpoint

A written diagnostic sequence for one described house (slab-on-grade, one story, sandy soil) with the purpose of each measurement.

Week 5

Radon Mitigation and Soil Gas (mitigation specialist scope, per NRPP Mitigation Specialist Exams and applicable ANSI/AARST mitigation standards)

  • Lay out the components of an active soil depressurization system and state the function of each: suction point, piping, fan, discharge location, sealing, and system monitor.

  • Size and route piping for three described buildings, stating the reasoning for diameter, slope, and termination point.

  • List the sealing and closure details required at penetrations, sumps, and crawlspace membranes.

  • Explain how the system monitor and a post-mitigation test confirm performance.

Your checkpoint

A component-by-component system design narrative for one described building, covering suction point, piping route, fan placement, discharge, and monitor.

Week 6

Radon Mitigation and Soil Gas (mitigation specialist scope, per NRPP Mitigation Specialist Exams and applicable ANSI/AARST mitigation standards)

  • Diagnose five written system failures (fan failure, blocked discharge, water in piping, inadequate suction field, backdrafting combustion appliances) and state the fix and the safety check.

  • Explain combustion-appliance safety testing and when it must be performed relative to system startup.

  • Describe post-mitigation verification: who tests, when, under what building conditions, and what result counts as success.

  • Draft the homeowner operating and maintenance instructions for a completed system.

Your checkpoint

A one-page homeowner handoff sheet covering system operation, monitor meaning, maintenance interval, and who to call.

Week 7

Radon Measurement (measurement professional scope, per NRPP Measurement Professional Exam and applicable ANSI/AARST measurement standards) & Radon Mitigation and Soil Gas (mitigation specialist scope, per NRPP Mitigation Specialist Exams and applicable ANSI/AARST mitigation standards)

  • Complete two timed mixed-domain practice sets and tag each miss by domain and by cause (knowledge gap, misread, or guess).

  • Re-teach the ten weakest concepts from memory in writing, then check against your notes.

  • Reconcile overlapping standards concepts: which requirements differ between measurement and mitigation work and which are shared.

  • Build a one-page formula and definition sheet you can reconstruct from memory.

Your checkpoint

A cause-tagged error analysis of at least 30 missed questions, with a re-teach note for the ten weakest concepts.

Week 8

Radon Measurement (measurement professional scope, per NRPP Measurement Professional Exam and applicable ANSI/AARST measurement standards) & Radon Mitigation and Soil Gas (mitigation specialist scope, per NRPP Mitigation Specialist Exams and applicable ANSI/AARST mitigation standards)

  • Take two full-length timed practice exams under exam conditions and record section timing.

  • Review only tagged weak concepts, not full content, in the final days.

  • Rehearse the reconstruction of the formula and definition sheet from blank paper.

  • Finalize exam-day logistics: identification, arrival time, calculator policy, and break strategy.

Your checkpoint

A final weak-concept list of no more than 15 items, each with a one-line correct statement, plus both practice exam scores logged.

Milestones

Week 2: You can explain, without notes, why each closed-building condition exists and name the QA samples required for a short-term test.

Week 4: You can rank soil gas entry driving forces and match three depressurization strategies to their site conditions in under five minutes.

Week 6: You can describe a complete system from suction point to monitor and name the combustion-safety check required before handoff.

Week 8: Both timed practice exams are complete with scores logged, and your final weak-concept list is 15 items or fewer.