NTN REACT flashcards
NTN REACT · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Multiplication factor k
- Ratio of neutrons in one generation to those in the preceding generation. k = 1 is critical, k > 1 supercritical, and k < 1 subcritical.
- Six-factor formula
- k = ε·p·f·η·P_FNL·P_TNL. It multiplies fast fission, resonance escape, thermal utilization, reproduction, and fast and thermal non-leakage probabilities.
- Reactivity in dollars
- Reactivity ρ = (k−1)/k. Expressed in dollars, ρ/$ where $ equals β, the effective delayed neutron fraction, about 0.0065 for U-235.
- Prompt criticality
- A condition reached when reactivity equals or exceeds the delayed neutron fraction β. The reactor then becomes prompt critical and power can rise very rapidly.
- Xenon-135 poisoning
- A fission product with very high neutron absorption cross-section. Post-shutdown peak worth occurs roughly 8–10 hours after shutdown as iodine-135 decays.
- Inverse count rate plot
- A startup technique plotting 1/M against rod position or boron concentration. Extrapolation to zero indicates the criticality condition.
- Shutdown margin
- The reactivity worth of all control rods minus the highest-worth stuck rod, with the reactor at power and equilibrium poisons. It must remain positive.
- Power defect
- The reactivity change from zero to full power caused by Doppler, moderator temperature, and void feedback. Rod withdrawal compensates for it.
- Moderator temperature coefficient
- The change in reactivity per unit change in moderator temperature. A negative coefficient provides inherent load-following and shutdown feedback.
- Differential rod worth
- The change in reactivity per unit rod motion. It is largest near mid-core and smallest at the top and bottom of the core.
- Equivalent dose
- Absorbed dose multiplied by the radiation weighting factor w_R, expressed in sievert. Photons have w_R = 1; alpha particles have w_R = 20.
- ALARA
- As Low As Reasonably Achievable. Doses are minimized considering economic and social factors, and the principle is documented in radiation protection programs.
- Half-value layer
- The thickness of shielding material that reduces radiation intensity by half. Related to attenuation coefficient by HVL = ln2/μ.
- Inverse square law
- Dose rate from a point source falls with the square of distance. Doubling the distance reduces the dose rate to one quarter.
- Derived air concentration
- The concentration of a radionuclide in air that, if inhaled for a working year, would deliver the annual limit on intake. Used for airborne monitoring.
- Emergency classification levels
- A graded scale from Notification of Unusual Event through Alert and Site Area Emergency to General Emergency, based on actual or potential radiological impact.
- Emergency action levels
- Pre-defined measurable conditions or instrument readings that trigger each emergency classification level. They must be based on observable plant parameters.
- ECCS acceptance criteria
- Peak cladding temperature must not exceed 2200°F (1204°C), cladding oxidation must not exceed 17%, and a coolable geometry must be maintained.
- Hydrogen flammability limit
- Hydrogen concentration in containment must be kept below about 4% by volume to prevent deflagration. Recombiners or venting control post-accident hydrogen.
- Critical safety functions
- Reactivity control, reactor coolant inventory, heat removal, and containment integrity. Emergency procedures are symptom-based and address these functions.
- Pressurizer function
- Maintains primary system pressure using electric heaters to raise pressure and spray to lower it, and accommodates coolant volume changes during power maneuvers.
- Steam generator tube boundary
- The tubes separate primary and secondary coolant. Degradation is monitored by eddy current testing, and plugging reduces heat transfer area.
- Residual heat removal system
- Removes decay heat after shutdown and cools the refueling pool. It requires adequate coolant inventory and a correctly aligned flow path.
- Safety injection
- Injects borated water to restore primary inventory and provide reactivity control after a loss-of-coolant accident. High- and low-pressure systems operate at different pressures.
- BWR direct cycle
- Reactor coolant boils in the core at about 7 MPa. Steam separators and dryers produce high-quality steam that drives the turbine directly.
- Source range detectors
- Proportional counters sensitive to individual neutrons. They measure count rate during shutdown and startup, when neutron population is very low.
- Intermediate range detectors
- Compensated ion chambers that measure log power in decades per minute. High flux trip setpoints are typically in the 10–40% power range.
- Axial offset
- (Top power − bottom power)/(top + bottom power), derived from power range detector readings. It monitors core power distribution and is limited by technical specifications.
- Reactor period
- The time for reactor power to change by a factor of e. Period meters measure T = ln2/λ, and an 18-second period is a typical startup alarm threshold.
- Coincidence voting logic
- Safety instrumentation uses multiple independent channels with 2-out-of-4 voting. This reduces spurious trips while ensuring a trip occurs on genuine demand.
- Limiting conditions for operation
- Technical specification requirements that define the minimum equipment and performance needed to operate safely, including action statements and completion times.
- Licensee event report
- A written report required by 10 CFR 50.73 within 60 days of specified events. Immediate notification of certain events is required under 10 CFR 50.72.