NV Fire Alarm · Get comfortable with the vocabulary.

Annunciator

A remote display panel that shows the status of a fire alarm system, including alarm, supervisory, and trouble conditions, by zone or device, so responders can locate the source without going to the main control unit.

Related: Fire Alarm Control Unit, Supervisory Signal, Trouble Signal
Addressable Device

An initiating or notification device that carries a unique digital identifier on the signaling line circuit, letting the control unit report its exact location and status rather than only a general zone.

Related: Signaling Line Circuit, Conventional Zone, Initiating Device Circuit
Alarm Signal

An audible or visible output produced by the system to warn occupants of a fire emergency, distinct from supervisory and trouble signals, and typically activated automatically by an initiating device or manually by a pull station.

Related: Notification Appliance Circuit, Supervisory Signal, Trouble Signal
Analog Addressable

A system architecture in which the control unit polls intelligent sensors for analog values such as smoke obscuration or temperature, then applies programmed thresholds and algorithms to decide whether an alarm condition exists.

Related: Addressable Device, Signaling Line Circuit, Detector Sensitivity
Audible Notification Appliance

A device such as a horn, bell, chime, or speaker that produces sound to alert occupants, evaluated for sound pressure level, temporal pattern, and audibility above ambient noise in the protected space.

Related: Visible Notification Appliance, Notification Appliance Circuit, Temporal-Three Pattern
Battery Calculations

The documented arithmetic proving secondary batteries can carry the system's standby load for the required duration plus the alarm load afterward, accounting for aging and voltage drop at end of discharge.

Related: Secondary Power Supply, Standby Power, Voltage Drop
Booster Power Supply

A remotely mounted power supply, often with its own battery, used to energize notification appliance circuits when the main control unit's output capacity or wiring distances cannot supply the required appliance load.

Related: Notification Appliance Circuit, Secondary Power Supply, Voltage Drop
Class A Circuit

An initiating or notification circuit wired so that a single open or ground fault does not prevent operation of devices beyond the fault; the circuit leaves and returns to the same panel terminals.

Related: Class B Circuit, Initiating Device Circuit, Notification Appliance Circuit
Class B Circuit

A two-wire circuit that leaves the panel, serves devices, and ends at an end-of-line device; an open fault disables all devices beyond the break, though the panel still supervises the wiring.

Related: Class A Circuit, End-of-Line Resistor, Initiating Device Circuit
Conventional Zone

A grouping of initiating devices on shared wiring that reports to the panel as a single point, so the panel identifies the area but not the individual device that operated.

Related: Addressable Device, Initiating Device Circuit, Zone
Detector Sensitivity

A measured response characteristic of a smoke detector, expressed as obscuration per unit length or percent per foot, that must be checked at installation and periodically to confirm the device remains within its listed range.

Related: Analog Addressable, Smoke Detector, Inspection and Testing
Duct Smoke Detector

A detector mounted on or in an air-handling duct that samples airflow to sense smoke, used to control fan shutdown and damper operation and to satisfy code requirements for duct smoke detection.

Related: Smoke Detector, Supervisory Signal, Air Sampling Detector
End-of-Line Resistor

A resistor installed at the far end of a conventional circuit that provides a supervised normal current; the panel reads a change in that current as an alarm, open, or short condition.

Related: Class B Circuit, Initiating Device Circuit, Supervision
Fire Alarm Control Unit

The central panel that receives signals from initiating devices, processes them according to its programming, and operates notification appliances and auxiliary functions while monitoring its own power and circuits.

Related: Annunciator, Signaling Line Circuit, Supervisory Signal
Fire Alarm Plan Review

The formal examination of submitted drawings, calculations, and specifications by an authority to confirm the proposed system meets adopted codes and standards before installation begins.

Related: Record of Completion, As-Built Drawings, Permit
Ground Fault

An unintended connection between a circuit conductor and earth or the enclosure, detected by the panel's ground-fault sensing so the condition is reported as a trouble rather than left hidden.

Related: Trouble Signal, Supervision, Class A Circuit
Heat Detector

A device that responds to thermal energy, either fixed temperature, rate-of-rise, or a combination, and is chosen where smoke detection would be unreliable or where rapid heat rise signals fire.

Related: Smoke Detector, Initiating Device Circuit, Detector Spacing
Initiating Device Circuit

The wiring path connecting automatic detectors and manual pull stations to the control unit, supervised against opens, shorts, and grounds so a fault is annunciated as a trouble condition.

Related: Class B Circuit, Addressable Device, Supervision
Inspection and Testing

The recurring field activities of visually examining and functionally operating system components at code-specified intervals, then documenting results and correcting deficiencies found during the work.

Related: Detector Sensitivity, Record of Completion, Supervision
Manual Pull Station

A manually operated initiating device, typically a lever or pull handle, installed along the means of egress so occupants can activate the alarm without waiting for automatic detection.

Related: Initiating Device Circuit, Alarm Signal, Mounting Height
Nevada State Fire Marshal

The state office responsible for fire prevention and code enforcement, including plan review and inspection authority over certain occupancies and jurisdictions under Nevada fire protection statutes.

Related: Authority Having Jurisdiction, Fire Alarm Plan Review, Permit
NFPA 72

The national fire alarm and signaling code that governs installation, performance, inspection, testing, and maintenance of detection and notification systems, and is adopted in some form by Nevada jurisdictions.

Related: NFPA 70, Inspection and Testing, Record of Completion
NFPA 70

The National Electrical Code, which sets requirements for fire alarm circuit wiring methods, conductor installation, overcurrent protection, and grounding that fire alarm technicians must follow alongside NFPA 72.

Related: NFPA 72, Voltage Drop, Ground Fault
Notification Appliance Circuit

The supervised output circuit that powers horns, strobes, speakers, or combination appliances, sized so voltage at the farthest appliance remains within its listed operating range under alarm load.

Related: Audible Notification Appliance, Visible Notification Appliance, Voltage Drop
Permit

The written authorization issued by a local or state authority allowing fire alarm installation, alteration, or repair work to proceed under approved plans and required inspections.

Related: Fire Alarm Plan Review, Nevada State Fire Marshal, Record of Completion
Positive Alarm Sequence

A programmed feature that delays general alarm for a limited period while trained staff investigate, provided the signal is acknowledged within a short window and the delay is permitted by the authority.

Related: Alarm Signal, Supervisory Signal, Fire Alarm Control Unit
Record of Completion

A document completed at system acceptance that records the installed configuration, device counts, battery calculations, and signatures confirming the system was installed and tested as designed.

Related: Inspection and Testing, As-Built Drawings, Fire Alarm Plan Review
Secondary Power Supply

The stored-energy source, usually rechargeable batteries or an engine-driven generator, that keeps the fire alarm system operational when normal building power fails or is interrupted.

Related: Battery Calculations, Standby Power, Booster Power Supply
Signaling Line Circuit

The addressable data loop or path connecting intelligent devices to the control unit, carrying both power and digital communication and supervised for opens, shorts, and ground faults.

Related: Addressable Device, Analog Addressable, Class A Circuit
Smoke Detector

A device that senses airborne combustion products, using ionization, photoelectric, or air-sampling technology, and reports an alarm or pre-alarm to the control unit.

Related: Heat Detector, Detector Sensitivity, Duct Smoke Detector
Standby Power

The condition in which the system runs on secondary batteries with no alarm active, the period used in battery calculations to prove capacity for the code-required duration.

Related: Secondary Power Supply, Battery Calculations, Booster Power Supply
Supervision

Continuous electrical monitoring of circuit integrity and power so that opens, shorts, grounds, or loss of power are annunciated as troubles instead of silently disabling protection.

Related: Trouble Signal, End-of-Line Resistor, Ground Fault
Supervisory Signal

A signal indicating an off-normal condition in a system component that could impair performance if uncorrected, such as a closed valve, low battery, or duct detector trouble, distinct from fire alarm.

Related: Trouble Signal, Alarm Signal, Fire Alarm Control Unit
Temporal-Three Pattern

The standard audible evacuation cadence of three pulses followed by a pause, repeated, which is recognizable as a fire alarm and required for many occupancies unless voice evacuation is used.

Related: Audible Notification Appliance, Alarm Signal, Voice Evacuation System
Trouble Signal

An audible and visible indication that a circuit, power source, or component is not functioning properly, alerting building staff to a condition needing service rather than a fire emergency.

Related: Supervisory Signal, Supervision, Ground Fault
Visible Notification Appliance

A strobe or other light source that flashes to alert occupants who are deaf or hard of hearing, with candela ratings and mounting heights set by code for the space covered.

Related: Audible Notification Appliance, Notification Appliance Circuit, Mounting Height
Voice Evacuation System

An emergency communication arrangement using amplified speakers and prerecorded or live messages to direct occupants, often required in large or high-rise occupancies instead of tone-only signaling.

Related: Temporal-Three Pattern, Notification Appliance Circuit, Audible Notification Appliance
Voltage Drop

The loss of voltage along a conductor caused by its resistance and the current drawn, calculated to confirm appliances at the end of a circuit still receive their listed operating voltage.

Related: Notification Appliance Circuit, Booster Power Supply, NFPA 70
Zone

A defined area or grouping of devices used by the control unit to identify where an alarm or trouble originates, and to organize annunciation and response for building occupants and responders.

Related: Conventional Zone, Annunciator, Addressable Device