NV Water/Wastewater Operator key terms
NV Water/Wastewater Operator · Get comfortable with the vocabulary.
- Coagulation
- Related: Flocculation, Turbidity, Jar Test
The rapid mixing of a chemical such as alum into raw water so that tiny suspended particles destabilize and begin to clump together. It is the first step of conventional filtration and is followed by flocculation.
- Flocculation
- Related: Coagulation, Sedimentation, Turbidity
Gentle, slow stirring of chemically treated water that encourages destabilized particles to collide and grow into larger, settleable clumps called floc. It follows coagulation and precedes sedimentation.
- Sedimentation
- Related: Flocculation, Sludge, Filtration
A gravity process in which water sits quietly in a basin long enough for heavier suspended solids and floc to settle to the bottom as sludge. Also called clarification when paired with chemical treatment.
- Filtration
- Related: Turbidity, Backwash, Disinfection
Passing water through a bed of sand, anthracite, or other media to trap remaining particles, including protozoan cysts, after settling. It is a physical barrier and typically the final particle-removal step before disinfection.
- Backwash
- Related: Filtration, Turbidity, Filter Run
Reversing flow upward through a filter bed at a rate high enough to lift and scrub the media, flushing trapped solids to waste. Operators trigger it on headloss, turbidity, or run time and must return the filter to service properly.
- Turbidity
- Related: Filtration, Coagulation, Nephelometer
The cloudiness of water caused by suspended particles that scatter light. Measured in nephelometric turbidity units, it is a key indicator of filtration performance and a required monitoring parameter for pathogen control.
- Nephelometer
- Related: Turbidity, Calibration
A laboratory or online instrument that measures turbidity by detecting light scattered at an angle by particles in a sample. Proper calibration and sample handling are essential because readings drive regulatory compliance decisions.
- Disinfection
- Related: CT Value, Chlorine Residual, Disinfection Byproducts
Inactivating disease-causing microorganisms in treated water, usually with chlorine, chloramine, ozone, or ultraviolet light. It differs from sterilization because it does not necessarily kill every organism present.
- CT Value
- Related: Disinfection, Chlorine Residual, Contact Time
The product of disinfectant concentration (C) and contact time (T) used to demonstrate that a required level of pathogen inactivation has been achieved. CT requirements vary by disinfectant, target organism, temperature, and pH.
- Chlorine Residual
- Related: Disinfection, CT Value, Boil Water Notice
The concentration of chlorine still present in water after treatment, reported as free or total chlorine. A detectable residual protects against contamination in the distribution system and is a required monitoring value.
- Disinfection Byproducts
- Related: Disinfection, Total Organic Carbon, Chlorine Residual
Chemicals such as trihalomethanes and haloacetic acids that form when disinfectants react with naturally occurring organic matter. Operators manage them by controlling precursor organics and balancing disinfection against byproduct formation.
- Total Organic Carbon
- Related: Disinfection Byproducts, Coagulation
A measure of the organic material in water that can react with disinfectants to form byproducts and contribute to color, taste, and odor. Removal is tracked across coagulation and filtration to judge treatment effectiveness.
- Jar Test
- Related: Coagulation, Flocculation
A bench-scale simulation in which several beakers of raw water receive different coagulant doses and mixing speeds, so the operator can select the dose and conditions that produce the best floc and settled clarity.
- Calibration
- Related: Nephelometer, Chlorine Residual
Adjusting an instrument so its readings agree with a known standard, then documenting the result. Regular calibration of turbidimeters, chlorine analyzers, pH meters, and flow meters underpins trustworthy compliance data.
- Cross Connection
- Related: Backflow Prevention, Boil Water Notice
Any actual or potential link between a potable water system and a source of nonpotable water or contamination. Preventing and controlling these links is central to protecting distribution system water quality.
- Backflow Prevention
- Related: Cross Connection
Devices and practices that stop water from flowing backward into a potable system, such as air gaps, reduced-pressure zone assemblies, and vacuum breakers. Selection depends on the degree of hazard and local rules.
- Boil Water Notice
- Related: Cross Connection, Chlorine Residual
A public health advisory telling customers to boil water before drinking or cooking because the supply may contain pathogens. Operators issue it after pressure loss, treatment failures, or confirmed contamination and lift it only after testing clears the system.
- Water Hammer
- Related: Pressure Gauge, Hydraulic Grade Line
A pressure surge caused by a sudden change in flow velocity, such as rapid valve closure or pump shutdown, that travels through piping as a shock wave. It can damage pipes and fittings and is controlled with slow-closing valves and surge protection.
- Hydraulic Grade Line
- Related: Water Hammer, Pressure Gauge
A graphical line showing the pressure head plus elevation of water at points along a pipeline or system. Comparing it with pipe elevations reveals where pressures are adequate, excessive, or where flow will not occur.
- Pressure Gauge
- Related: Water Hammer, Hydraulic Grade Line
An instrument that displays the pressure of water in a pipe or system, usually in psi or kPa. Operators use gauges to confirm pump performance, detect restrictions, and verify that service pressures stay within required ranges.
- Flushing
- Related: Chlorine Residual, Distribution System
Deliberately running water through mains or hydrants to remove sediment, stale water, and biofilm and to restore disinfectant residual. Unidirectional flushing uses planned valve closures to increase scouring velocity.
- Distribution System
- Related: Flushing, Storage Tank
The network of pipes, storage tanks, pumps, valves, and hydrants that delivers finished water from the treatment plant to customers. Maintaining pressure and disinfectant residual throughout it is a core operator duty.
- Storage Tank
- Related: Distribution System, Flushing
A reservoir that holds treated water to meet peak demand, provide fire flow, and maintain pressure. Tanks need routine inspection, mixing, and turnover to prevent stagnation, sediment buildup, and loss of residual.
- Influent
- Related: Effluent, Biochemical Oxygen Demand
The wastewater entering a treatment plant or a specific treatment unit. Its flow rate and strength (BOD, TSS, ammonia) set the loading the process must handle and guide operational adjustments.
- Effluent
- Related: Influent, National Pollutant Discharge Elimination System
The treated water leaving a treatment plant or process unit, which must meet permit limits before discharge or reuse. Effluent monitoring results demonstrate whether the plant is performing as required.
- Biochemical Oxygen Demand
- Related: Influent, Total Suspended Solids, Aeration
The amount of dissolved oxygen microorganisms consume while breaking down organic matter in a sample over a set period, usually five days. It estimates organic strength and is a common permit limit for effluent.
- Total Suspended Solids
- Related: Biochemical Oxygen Demand, Clarifier, Effluent
The concentration of solid particles suspended in water or wastewater, determined by filtering a sample, drying it, and weighing the residue. It is a primary permit parameter and a gauge of treatment and settling performance.
- Aeration
- Related: Activated Sludge, Dissolved Oxygen, Biochemical Oxygen Demand
Supplying air or oxygen to wastewater so aerobic bacteria can oxidize organic matter and ammonia. Operators control blower output and dissolved oxygen levels to keep the biological process healthy without wasting energy.
- Activated Sludge
- Related: Aeration, Return Activated Sludge, Mixed Liquor Suspended Solids
A biological treatment process in which a mixed community of microorganisms is kept suspended in aerated wastewater and then separated in a clarifier, with settled biomass returned to the aeration basin to treat more flow.
- Mixed Liquor Suspended Solids
- Related: Activated Sludge, Food-to-Microorganism Ratio, Return Activated Sludge
The concentration of suspended solids, mostly microorganisms, in the aerated mixed liquor of an activated sludge basin. It is used with other data to calculate solids inventory and the food-to-microorganism ratio.
- Return Activated Sludge
- Related: Activated Sludge, Waste Activated Sludge, Clarifier
Settled biological solids collected from the clarifier bottom and pumped back to the aeration basin to maintain the microorganism population needed for treatment. The return rate is adjusted to control solids inventory.
- Waste Activated Sludge
- Related: Return Activated Sludge, Solids Retention Time, Sludge
Excess biological solids deliberately removed from the activated sludge system to control solids retention time and prevent overloading the clarifiers. Wasting rate is a primary lever for managing sludge age.
- Solids Retention Time
- Related: Waste Activated Sludge, Nitrification, Mixed Liquor Suspended Solids
The average time biological solids remain in the treatment system before being wasted, also called sludge age or mean cell residence time. It strongly influences nitrification, settling, and effluent quality.
- Food-to-Microorganism Ratio
- Related: Mixed Liquor Suspended Solids, Activated Sludge, Biochemical Oxygen Demand
The mass of organic food entering the aeration basin divided by the mass of microorganisms present, often expressed as F/M. It indicates whether biomass is underloaded or overloaded and helps predict sludge settling behavior.
- Dissolved Oxygen
- Related: Aeration, Activated Sludge, Nitrification
The concentration of oxygen dissolved in water, critical for aerobic treatment and for aquatic life in receiving streams. Low levels in an aeration basin can cause poor treatment, odors, and settling problems.
- Nitrification
- Related: Solids Retention Time, Dissolved Oxygen, Denitrification
The biological conversion of ammonia to nitrite and then nitrate by specialized bacteria. It consumes large amounts of oxygen and alkalinity and is sensitive to cold temperatures and short solids retention times.
- Denitrification
- Related: Nitrification, Clarifier
The biological conversion of nitrate to nitrogen gas under low-oxygen conditions, often used to meet total nitrogen limits. If it occurs in a clarifier, the released gas can float sludge and degrade effluent quality.
- Clarifier
- Related: Total Suspended Solids, Return Activated Sludge, Sludge Blanket
A settling tank that separates solids from liquid, either as primary clarification ahead of biological treatment or as secondary clarification after it. Operators watch sludge blankets and weirs to prevent solids carryover.
- Sludge Blanket
- Related: Clarifier, Return Activated Sludge, Sludge
The layer of settled solids at the bottom of a clarifier. Its depth and clarity indicate whether sludge is being returned or wasted at the right rate and whether solids are at risk of washing over the weirs.
- Sludge
- Related: Waste Activated Sludge, Sedimentation
The solids removed from wastewater during treatment, including primary and waste biological solids. Handling, thickening, dewatering, and disposal of sludge are major operational costs and regulatory responsibilities.
- Infiltration and Inflow
- Related: Sanitary Sewer Overflow, Collection System, Peak Flow
Extraneous water entering a collection system through groundwater seepage (infiltration) or direct connections such as storm drains and sumps (inflow). It adds flow that can overload pipes and treatment units during wet weather.
- Sanitary Sewer Overflow
- Related: Infiltration and Inflow, Collection System
An unauthorized release of untreated sewage from a collection system, often during blockages or wet-weather overloads. Operators must respond quickly, contain and report the spill, and address the underlying cause.
- Collection System
- Related: Lift Station, Sanitary Sewer Overflow, Infiltration and Inflow
The network of gravity sewers, lift stations, force mains, and manholes that carries wastewater from homes and businesses to the treatment plant. Its condition and capacity directly affect plant flows and overflow risk.
- Lift Station
- Related: Collection System, Sanitary Sewer Overflow
A facility with pumps that raise wastewater to a higher elevation so it can continue by gravity. Reliable operation, wet-well level control, and backup power are essential to prevent overflows.
- National Pollutant Discharge Elimination System
- Related: Effluent, Total Suspended Solids
The federal permitting program that sets limits and monitoring requirements for wastewater discharged to surface waters. Each plant's permit defines allowable effluent concentrations, reporting, and compliance schedules.