PGDB Certifying Gasfitter · Keep the key ideas within reach.

Quick reference

Gas Codes, Regulations, and Standards

  • In Canada the CSA B149.1 Natural Gas and Propane Installation Code governs installation; B149.2 covers propane storage and handling, and B149.3 covers appliance and equipment approval.

  • The Gas Protection Branch (municipal/ provincial authority) issues gasfitter licences and permits; work must not proceed without the required permit and inspection notice.

  • Code requirements are minimums; manufacturer's certified installation instructions always take precedence where they are more restrictive.

  • Clearances to combustible material are measured from the appliance or vent surface to the combustible surface; reduced clearances require an approved listed clearance shield or protection per the certification.

  • A field approval (special inspection) is required for unlisted appliances or equipment; the authority having jurisdiction must approve before installation.

  • B149.1 requires that alterations, additions, and repairs be performed by a certified gasfitter holding the appropriate class, and that the installation be left in a safe condition.

  • Definitions matter on exams: 'approved' means acceptable to the authority having jurisdiction; 'listed' means certified by a recognized testing agency (e.g., CSA, ULC, Intertek, UL).

  • Propane cylinder exchange and refilling are regulated separately; a gasfitter may only perform work within the scope of their certificate class (e.g., Class A, B, or C).

Quick reference

Properties and Combustion of Fuel Gases

  • Complete combustion of methane: CH4 + 2O2 → CO2 + 2H2O; each volume of methane requires two volumes of oxygen (about 9.5 volumes of air).

  • Propane combustion: C3H8 + 5O2 → 3CO2 + 4H2O; stoichiometric air requirement is approximately 23.8 volumes of air per volume of propane.

  • Natural gas heating value is roughly 1,000–1,050 BTU/ft³ (about 37 MJ/m³); propane vapour is about 2,500 BTU/ft³ (about 93 MJ/m³); butane about 3,200 BTU/ft³.

  • Specific gravity: natural gas ≈ 0.60 (lighter than air, rises and vents at high points); propane vapour ≈ 1.52 (heavier than air, settles in low areas, pits, and basements).

  • Flammable limits in air: natural gas ≈ 4–15% by volume; propane ≈ 2.1–9.5% by volume. Below the LFL the mixture is too lean, above the UFL too rich, to ignite.

  • Propane liquid expands roughly 1.5% per 10°F (about 1.5% per 5.5°C); cylinders must never be filled beyond 80% liquid capacity to allow for expansion.

  • Ignition temperature: natural gas ≈ 1,100°F (593°C); propane ≈ 920–1,020°F (about 493–550°C).

  • Excess air (O2 in flue gas) indicates dilution; CO in flue gas indicates incomplete combustion. CO2 max for natural gas is about 11.7–12%; for propane about 13.8%.

Quick reference

Venting, Flueing, and Combustion Air

  • Category I appliances are non-condensing, negative draft, and vent with B-vent; Category III are positive pressure non-condensing; Category IV are condensing positive pressure (use listed PVC/CPVC/stainless per manufacturer).

  • Natural draft (B-vent) systems rely on a warm flue and adequate draft; a blocked flue or downdraft spills products of combustion into the space, creating CO hazard.

  • Combustion air: the 'tight construction' rule requires outdoor air; conventional opening sizing uses 1 in² free area per 1,000 BTU/h input for two permanent openings (or per code table).

  • For a confined space, two openings (high and low) are required, each sized to the total input; a louvered grille reduces free area and must be compensated (metal louvers ≈ 75% free area, wood ≈ 25%).

  • Vent connectors must slope upward toward the chimney at minimum 1/4 in per foot (about 20 mm/m) for natural draft appliances, and be as short and direct as possible.

  • A vent termination must be located away from windows, doors, and air intakes per code clearances (typically 3 ft/1 m horizontally from an operable window or intake, and above roof snow line).

  • Side-wall power venters must be listed for the appliance and installed per manufacturer clearances; condensate from Category IV vents must be drained and neutralized where required.

  • Draft hood/spill switch: a blocked flue can cause spillage at the draft hood; a spill switch (spillage switch) shuts off the burner on detected spillage.

Quick reference

Pipe Sizing, Installation, and Pressure Testing

  • Sizing methods: longest-length (longest run) method and branch-length method; use the total connected load and the longest equivalent length to select pipe size from code tables.

  • Equivalent length adds fittings: a 90° elbow ≈ 5 ft, a 45° elbow ≈ 2.5 ft, a tee (flow through branch) ≈ 10 ft, and a gate valve ≈ 1 ft of straight pipe (values per code tables).

  • Natural gas pressure drop allowance for low-pressure systems is typically 0.5 in w.c. from meter to appliance; propane systems use 0.5 in w.c. for 11 in w.c. supply.

  • Minimum size limits: no gas piping smaller than 1/2 in nominal; appliance connectors must be listed and not exceed 6 ft (1.8 m) for movable appliances, and must not pass through walls or floors.

  • Pressure test: new natural gas piping is tested with air or inert gas at not less than 1.5 times the maximum working pressure, minimum 10 psig (or per code) for a specified duration, with no pressure drop.

  • Leak testing must never be done with a flame; use soap solution, a combustible gas detector, or a manometer. A pressure gauge must be sized so the test pressure is at mid-scale.

  • Pipe support and protection: piping must be supported at intervals per code (typically every 6 ft/1.8 m for small sizes), protected from physical damage, and not run through ducts, chimneys, or elevator shafts.

  • Drip legs (sediment traps) are required at the inlet of appliances; the leg must be at least 3 in (75 mm) deep and installed downstream of the shutoff valve.

Quick reference

Gas Appliances and Equipment Installation

  • Every appliance must be installed per its certified listing and manufacturer's instructions; the data plate gives input rating, manifold pressure, orifice size, and clearances.

  • Manifold pressure: natural gas appliances typically 3.5 in w.c. (some 3.5–4.0 in w.c.); propane appliances typically 10–11 in w.c. Supply pressure at the appliance inlet must be within the manufacturer's specified range.

  • A manual shutoff valve must be installed in the supply line within 6 ft (1.8 m) of the appliance and be readily accessible and clearly identified.

  • A union or flanged connection is required between the shutoff valve and the appliance to allow removal; appliance connectors must be listed and protected from damage.

  • Clearances to combustibles: maintain the listed clearances on all sides and above; a clearance reduction requires a listed shield or approved non-combustible protection installed per code.

  • Appliance flue and draft hood must be properly connected and sized to the appliance; a draft hood must not be modified, and the relief opening must remain unobstructed.

  • For appliances installed in garages, ignition sources must be at least 18 in (450 mm) above the floor for propane (heavier than air) and the appliance protected from vehicle impact.

  • Combustion air and ventilation openings must not be obstructed; after installation, verify gas supply pressure, manifold pressure, draft, and complete combustion before leaving the site.

Quick reference

Electrical Controls, Ignition, and Safety Devices

  • Thermocouples generate millivolts (typically 250–750 mV open circuit) from a pilot flame; the voltage holds the gas valve open via the safety magnet.

  • A thermopile generates higher voltage (typically 500–750 mV under load) and can power a millivolt gas valve and thermostat circuit without external power.

  • Flame rectification (flame sensing) uses the flame to conduct current between the sensor and burner; the control detects microamps (typically 1–10 µA) to prove flame.

  • Hot surface ignition (HSI) uses a silicon carbide or nitride igniter; test resistance with power off (typically 40–100 Ω, varies by manufacturer) and check for cracks.

  • Spark ignition (direct spark or intermittent pilot) requires a proper spark gap (typically 1/8 in/3 mm) and a good ground; a weak spark indicates a bad igniter, wire, or control.

  • Safety devices include: high-limit switch, rollout switch, blocked-vent pressure switch, flame rollout, and gas pressure switches; never bypass or jumper a safety device.

  • A rollout switch trips on flame rollout from a blocked flue or dirty burner; it is manual-reset and must be investigated before resetting.

  • Pressure switches prove draft or airflow; a stuck-open switch or blocked sensing tube causes ignition lockout or short cycling.

Quick reference

Troubleshooting, Servicing, and Maintenance

  • Diagnostic sequence: verify gas supply and pressure, then electrical supply and control voltage, then ignition sequence, then flame proving, then combustion and venting.

  • Pilot outage causes: dirty pilot orifice, misaligned pilot, weak thermocouple, draft/spillage, or gas supply interruption; clean or replace components rather than increasing pilot flame.

  • Short cycling often indicates a high-limit trip (restricted airflow, dirty filter, blocked flue) or a faulty thermostat/control; find the root cause, not just reset.

  • Burner maintenance: clean burner ports, check for rust, debris, or misalignment; a yellow lazy flame on natural gas indicates incomplete combustion and requires adjustment or cleaning.

  • Gas valve testing: check inlet and outlet pressures, verify the valve opens on call for heat, and confirm the operator coil or diaphragm operates; never disassemble a gas valve.

  • Manifold pressure must be set with a manometer with the appliance operating; adjust the regulator per the data plate and recheck after adjustment.

  • Soot deposits indicate incomplete combustion (rich mixture or blocked flue); soot is a fire and CO hazard and must be corrected, not just cleaned.

  • After service, perform a combustion test, leak test, and verify draft; document readings and leave the appliance operating safely.

Quick reference

Carbon Monoxide, Combustion Analysis, and Indoor Air Quality

  • CO is colourless, odourless, and slightly lighter than air; it binds haemoglobin about 200–250 times more readily than oxygen, causing tissue hypoxia.

  • Combustion analysis measures O2, CO2, CO, stack temperature, and ambient CO; calculate excess air and steady-state efficiency from these readings.

  • Target flue CO for natural gas appliances is typically under 100 ppm (air-free) for clean combustion; elevated CO indicates incomplete combustion.

  • CO2 max for natural gas ≈ 11.7–12% and for propane ≈ 13.8%; measured CO2 divided by CO2 max gives the percent of theoretical air used (or excess air = (CO2max/CO2measured − 1) × 100).

  • Dilution air lowers measured CO2 and raises measured O2; always convert CO readings to 'air-free' values for comparison.

  • Stack temperature rise plus O2/CO2 readings give steady-state efficiency; high stack temperature with low CO2 indicates excess air or heat exchanger fouling.

  • Indoor air quality hazards: spillage from natural draft appliances, backdrafting from exhaust fans, blocked vents, and unvented appliances; test for CO in the breathing zone.

  • CO alarm placement: outside sleeping areas and on each level; do not install within 5 ft of a fuel-burning appliance or in dead air spaces.

Quick reference

Safety, Tools, and Jobsite Practices

  • Personal protective equipment: safety glasses, gloves, and flame-resistant clothing when working on gas appliances; use a respirator when cutting or grinding.

  • Before working on gas piping, isolate and lock out/tag out the gas supply, and purge lines safely to a well-ventilated area.

  • Use a calibrated combustible gas detector (LEL meter) to check for leaks; soap bubbles confirm small leaks; never use a flame.

  • Tools: manometer for pressure testing, U-tube or digital; combustion analyzer for O2/CO/CO2/stack temperature; multimeter for electrical checks; thermocouple tester.

  • Confined space entry requires atmospheric testing for O2, combustible gas, and CO before entry, plus a standby attendant and permit.

  • Ladder safety: 4:1 rule (base 1 ft out for every 4 ft of height), three-point contact, and secure the ladder before climbing.

  • Electrical safety: lock out and tag out before servicing controls; verify with a meter that power is off; capacitor discharge before handling.

  • Jobsite housekeeping: keep combustibles away from appliances, protect openings, and secure cylinders upright with valves closed when not in use.

Quick reference

Customer Service, Documentation, and Professional Conduct

  • Document all work: date, appliance model and serial, readings (pressures, CO, draft), parts replaced, and tests performed; leave a copy with the customer.

  • Explain findings in plain language, present options and costs, and obtain approval before performing additional work.

  • A gasfitter must not perform work outside their licence class; refer to a qualified colleague or the authority when in doubt.

  • Confidentiality: customer information and property details must not be shared; obtain permission before taking photos.

  • Safety reporting: if a hazard is found (CO, gas leak, blocked vent), inform the occupant immediately, shut off the appliance if unsafe, and document the action taken.

  • Professional conduct includes punctuality, clean work area, respect for the customer's property, and honest communication about what was and was not done.

  • Invoices and work orders should reference the applicable code or manufacturer instruction when a repair or upgrade is required.

  • Follow-up: schedule a return visit for combustion analysis or leak recheck when a repair is made, and record the appointment.