OH Elevator Mechanic study materials
OH Elevator Mechanic study resources

OH Elevator Mechanic cheat sheet

OH Elevator Mechanic · Keep the key ideas within reach.

Quick reference

Elevator and Escalator Code Compliance

  • ASME A17.1/CSA B44 is the model safety code for elevators, dumbwaiters, escalators, and moving walks; ASME A17.3 governs existing installations, and A17.2 covers inspection procedures.

  • Ohio adopts the A17.1 elevator code with amendments in Ohio Administrative Code Chapter 4101:5; the Ohio Board of Building Standards administers elevator rules and certifications.

  • A17.1 requires a minimum overhead clearance and pit depth sized by car speed and counterweight runby; verify runby, buffer stroke, and refuge space before accepting an installation.

  • Escalator requirements include 30-degree maximum incline, 40-inch nominal step width, 24-inch minimum and 40-inch maximum rise per unit unless a code exception applies, and balustrade height of at least 36 inches.

  • Machine-room and machinery-space access, lighting (minimum 19 foot-candles at working surfaces), guarding, and a locked disconnect within sight of the controller are code-mandated.

  • Firefighters' emergency operation Phase I (recall) and Phase II (in-car operation) is required for most passenger elevators and must be tested per A17.1 acceptance criteria.

  • Door closing force on passenger elevators may not exceed 30 lbf kinetic and 30 lbf static measured per A17.1, with reopening devices required on car and hoistway doors.

  • Code upgrades for existing elevators are triggered by A17.3 when alterations exceed defined thresholds; major alterations require a permit and acceptance inspection.

Quick reference

Mechanical and Electrical Installation

  • Traction elevator roping: 1:1 roping gives car speed equal to rope speed; 2:1 roping doubles car travel per unit of rope travel, so the machine sheave runs at twice car speed.

  • Counterweight balance is typically 40-50 percent of rated load; counterweight weight equals car weight plus approximately 45 percent of capacity.

  • Governor tripping speed is set per A17.1 (commonly 115 percent of rated speed for car safeties) and must be verified with a tachometer during acceptance testing.

  • Guide rail alignment tolerances, rail bracket spacing, and plumb are set by A17.1 tables; rail gauge and fishplate torque must be recorded at installation.

  • Hydraulic elevator: relief valve set at 150 percent of working pressure (not to exceed 2.5 times working pressure), and the plunger, cylinder, and piping must be pressure tested before acceptance.

  • Electrical: feeder and branch-circuit conductor sizing, motor disconnects, controller grounding, and conduit fill follow NFPA 70 (NEC) Article 620 and Article 430.

  • Traveling cable must be supported and have sufficient length for full car travel plus an additional loop; strain relief and conductor count match car and hall fixtures.

  • Escalator drive: main drive chain tension, step chain sag, and handrail speed (within 2 percent of step speed) are checked at installation and after any drive work.

Quick reference

Maintenance, Inspection, and Testing

  • A17.1 Category 1 (annual) and Category 5 (five-year) tests are the standard periodic test regime; Category 5 includes rated-load and safety tests that annual testing does not cover.

  • Annual test items include car and counterweight safeties (no load), governor, oil buffers, terminal stopping devices, emergency brakes, and door reopening devices.

  • Five-year test adds full-load safety test, rated-load brake test, and relief valve test on hydraulic units; results must be recorded and retained.

  • Periodic inspection intervals in Ohio are set by rule; a certificate of operation must be posted in the car and renewed on schedule.

  • Maintenance records must document lubrication, adjustment, and repair of machine, ropes, sheaves, governor, safeties, buffers, and door operators.

  • Rope inspection: count broken wires over a lay length, check for corrosion, kinks, and reduction in diameter; retirement criteria follow A17.1 tables.

  • Escalator maintenance includes step chain elongation measurement, handrail tension and speed, skirt and comb plate clearance, and brake stopping distance.

  • A test tag or log entry must record date, tester, test performed, and results; failed items require correction before the unit returns to service.

Quick reference

Safety Practices and Ohio Regulations

  • Lockout/tagout per OSHA 29 CFR 1910.147 applies to elevator and escalator work; verify zero energy at the controller and at the machine before working on moving parts.

  • Before entering a pit or hoistway, place the car on inspection operation, open the pit stop switch, and use the pit ladder and required lighting.

  • Ohio requires elevator contractor and mechanic licensure through the Ohio Department of Commerce, Division of Industrial Compliance; work must be performed under a licensed contractor.

  • Permits are required for new installations and alterations; the state or a certified local authority performs plan review and acceptance inspection.

  • Personal protective equipment: hard hat, safety glasses, gloves, and fall protection when working at heights; hoistway work requires a tie-off point or temporary guard.

  • Never ride on top of a car unless the car-top operating device is in use and the car is on inspection speed; keep clear of the counterweight path.

  • Report accidents and serious injuries to the authority having jurisdiction; A17.1 requires investigation and reporting of certain incidents.

  • Electrical safe work practices follow NFPA 70E: arc-flash boundary, energized work permit, and voltage-rated gloves for live troubleshooting.