OH Elevator Mechanic flashcards
OH Elevator Mechanic · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- ASME A17.1
- Model safety code for elevators, escalators, dumbwaiters, and moving walks covering design, construction, installation, and acceptance testing requirements in the United States and Canada.
- ASME A17.3
- Safety code for existing elevators and escalators; specifies retroactive requirements and upgrades triggered when alterations exceed defined thresholds.
- Firefighters' Phase I recall
- Emergency operation that automatically or manually recalls cars to the designated landing, opens doors, and removes them from normal service when a fire alarm activates.
- Phase II in-car operation
- Firefighters' service mode allowing a firefighter to control the car from inside using the in-car key switch, with continuous-pressure door and travel controls.
- Door closing force limit
- Passenger elevator car and hoistway doors may not exceed 30 lbf kinetic or static closing force, measured per A17.1 test method.
- Escalator incline and rise
- Escalators are limited to a 30-degree maximum incline with a nominal 40-inch step width and a maximum rise per unit unless a code exception applies.
- Ohio elevator rule chapter
- Ohio Administrative Code Chapter 4101:5 contains the elevator rules adopted by the Ohio Board of Building Standards, including amendments to the model code.
- Machinery space lighting
- Machine rooms and machinery spaces require permanent lighting providing at least 19 foot-candles at working surfaces, with a switch at the entrance.
- 2:1 roping speed
- With 2:1 roping the car moves twice the distance the rope moves, so the machine sheave and rope run at twice car speed.
- Counterweight balance
- Counterweight mass is typically car mass plus about 45 percent of rated load, balancing the car and part of the load to reduce motor torque.
- Governor trip speed
- The speed at which the governor grips and activates the safety, commonly set at about 115 percent of rated speed for car safeties.
- Hydraulic relief valve setting
- The relief valve is set at 150 percent of working pressure, not exceeding 2.5 times working pressure, and is verified during acceptance testing.
- NEC Article 620
- National Electrical Code article covering elevators, dumbwaiters, escalators, moving walks, and lifts, including feeder, branch circuit, and disconnect requirements.
- Traveling cable support
- The traveling cable must be supported and sized for full car travel plus an extra loop, with strain relief and conductor count matching fixtures.
- Handrail speed tolerance
- Escalator handrail speed must be within 2 percent of step speed, measured under specified load conditions at installation and after drive work.
- Guide rail alignment
- Rail plumb, gauge, bracket spacing, and fishplate torque follow A17.1 tables and must be recorded at installation and after realignment.
- Category 1 test
- Annual periodic test covering car and counterweight safeties without load, governor, buffers, terminal stopping, emergency brake, and door reopening devices.
- Category 5 test
- Five-year periodic test adding rated-load safety test, rated-load brake test, and hydraulic relief valve test beyond the annual Category 1 items.
- Certificate of operation
- Document issued by the authority having jurisdiction confirming the unit passed inspection; it must be posted in the car and renewed on schedule.
- Rope retirement criteria
- Rope must be replaced when broken wires over a lay length, diameter reduction, corrosion, or kinks exceed the limits in A17.1 tables.
- Escalator step chain elongation
- Step chain wear is measured as elongation over a set span; exceeding the manufacturer or code limit requires chain replacement.
- Test log requirements
- Each test record must show date, tester identity, test performed, and results; failed items must be corrected before the unit returns to service.
- Buffer stroke check
- Oil buffer stroke and oil level are verified during periodic testing to confirm the buffer can decelerate the car or counterweight within code limits.
- Terminal stopping device test
- Annual test confirming normal and final terminal stopping devices stop the car before it reaches the buffer or overhead obstruction.
- Lockout/tagout
- OSHA 29 CFR 1910.147 procedure requiring energy isolation, lock and tag application, and zero-energy verification before work on moving parts.
- Pit stop switch
- Switch in the pit that removes power from the car and opens the pit circuit; it must be opened before entering the pit for work.
- Ohio contractor licensure
- Elevator contractors and mechanics are licensed through the Ohio Department of Commerce, Division of Industrial Compliance; work requires a licensed contractor.
- Acceptance inspection
- Inspection performed after installation or major alteration, including witness of required tests, before a certificate of operation is issued.
- Car-top operation
- Inspection-speed operation from the car top using the car-top station; the operator must keep clear of the counterweight path and overhead obstructions.
- NFPA 70E
- Standard for electrical safety in the workplace covering arc-flash boundaries, energized work permits, and voltage-rated PPE for live troubleshooting.
- Incident reporting
- Serious accidents and injuries involving elevator or escalator equipment must be reported to the authority having jurisdiction for investigation.
- Fall protection in hoistway
- Work at heights in a hoistway requires a tie-off point or temporary guardrail; fall arrest equipment is inspected before each use.