Oregon Low Voltage Practice flashcards
Oregon Low Voltage Practice · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Limited Energy Technician Class A
- Oregon certificate allowing installation, alteration, and repair of all limited energy systems, including fire alarm and nurse call, under a licensed electrical contractor.
- Limited Energy Technician Class B
- Oregon certificate limited to specified limited energy systems such as HVAC controls; fire alarm and nurse call work require additional qualification beyond Class B.
- Electrical contractor license
- Oregon business license required for any entity offering or performing electrical work; it is separate from the individual electrician or technician certificate.
- Supervising technician designation
- The individual limited energy technician or electrician named on a contractor license as responsible for the work; changes must be reported to the Building Codes Division.
- Electrical permit requirement
- Oregon requires a permit before electrical work begins, obtained from the local building department or Building Codes Division, with inspections at specified stages.
- OAR 918-282 scope
- Oregon administrative rule division defining limited energy electrical activity, including system types, power limits, and the Class A and Class B technician scopes.
- Statewide code uniformity
- Oregon adopts the NEC with state amendments through the Electrical Specialty Code; local jurisdictions may not adopt conflicting electrical requirements.
- OAR 918-311 coverage
- Oregon rule division governing electrical inspections and permits, including minor work allowances and the process for requesting inspection.
- Branch circuit definition
- NEC Article 100 defines it as the circuit conductors between the final overcurrent device protecting the circuit and the outlet or outlets.
- Working clearance 110.26
- Requires at least 36 inches depth, width of equipment or 30 inches, and 6 feet 6 inches headroom in front of electrical equipment.
- Conductor ampacity adjustment
- Table 310.16 ampacity must be corrected for ambient temperature and adjusted for more than three current-carrying conductors in a raceway or cable.
- Box fill calculation
- Table 314.16(A) assigns volume allowances per conductor, device, and grounding conductor; total allowance must not exceed the box volume.
- Plenum cable requirement
- NEC 300.22 requires plenum-rated cable such as CMP, FPLP, or CL3P in environmental air spaces; riser-rated cable is used in vertical shafts.
- Abandoned cable removal
- Accessible portions of abandoned limited energy cable must be removed unless identified for future use, per Article 800 and related sections.
- Article 760 fire alarm cable
- Power-limited fire alarm circuits use FPL, FPLR, or FPLP cable; non-power-limited circuits use NPLF cable with stricter separation requirements.
- Limited energy separation
- Class 2, Class 3, and communications cables must be separated from power conductors by a barrier or spacing unless a listed exception applies.
- Equipment grounding conductor sizing
- Table 250.122 sizes the equipment grounding conductor based on the rating of the overcurrent device protecting the circuit.
- Bonding versus grounding
- Bonding connects metal parts to ensure electrical continuity; grounding connects the system to earth. Article 250 treats them as distinct requirements.
- Listed Class 2 power supply
- A supply listed to limit output voltage and current so the circuit cannot deliver hazardous energy, permitting reduced wiring and protection requirements.
- Short-circuit current rating
- Equipment must have a short-circuit current rating equal to or greater than the available fault current at its terminals per NEC 110.9 and 110.10.
- NFPA 72 supervision
- Fire alarm initiating and notification circuits must be supervised to detect opens, grounds, and shorts unless a specific code exception applies.
- Smoke detector spacing
- NFPA 72 Chapter 17 spacing depends on ceiling height, ceiling configuration, and air movement rather than a single fixed distance.
- Fire alarm panel listing
- The control panel must be listed for the purpose and installed per manufacturer instructions; unlisted field modifications may void the listing and system approval.
- Communication circuit protection
- Article 800 requires primary protectors and other safeguards where communications circuits are exposed to outside plant and enter a building.
- Class 2 versus Class 3
- Article 725 distinguishes them by power source limits in Table 725.121; Class 2 has lower limits and permits less physical protection than Class 3.
- CL3P cable marking
- The P suffix indicates plenum rating for Class 3 cable; the R suffix indicates riser rating, and the marking must match the installed environment.
- Class 2 circuit separation
- Class 2 and Class 3 circuits must be separated from power and Class 1 circuits by a permanent barrier or spacing per NEC 725.136.
- Power-limited circuit listing
- The listing of the Class 2 or Class 3 power supply is the basis for reduced wiring requirements because it limits available output energy.
- Arc flash risk assessment
- NFPA 70E requires assessing incident energy or arc flash PPE category to select PPE appropriate for the working distance and task.
- Energized work permit
- NFPA 70E 130.2 permits energized work only when de-energization is infeasible, and then only with an energized electrical work permit and PPE.
- Test instrument CAT rating
- CAT III applies to distribution-level circuits, CAT IV to service entrance, and CAT II to branch circuits and plug-connected loads; the rating must match the circuit.
- Approach boundaries
- Limited, restricted, and arc flash boundaries limit access; only qualified persons may cross the limited approach boundary, with more justification for the restricted boundary.