Oregon Low Voltage Practice key terms
Oregon Low Voltage Practice · Get comfortable with the vocabulary.
- Oregon Electrical Specialty Contractor License
- Related: Oregon Electrical Specialty Electrician, Oregon Building Codes Division
A license issued by the Oregon Building Codes Division authorizing a business to perform electrical work within a specific specialty, such as low voltage, under the supervision of a licensed electrician.
- Oregon Electrical Specialty Electrician
- Related: Oregon Electrical Specialty Contractor License
An individual licensed by the state of Oregon to perform electrical work limited to a specific scope, such as low voltage systems, after meeting experience and examination requirements.
- Oregon Building Codes Division (BCD)
- Related: OAR 918-281, Oregon Electrical Specialty Contractor License
The state agency responsible for administering and enforcing Oregon's building codes, including electrical licensing, permits, and inspections, and for adopting electrical rules under OAR chapter 918.
- OAR 918-281
- Related: Oregon Building Codes Division, Electrical Permit
Oregon Administrative Rules chapter 918, division 281, which sets forth the scope of electrical work, licensing requirements, and permit procedures for electrical contractors and electricians in Oregon.
- Electrical Permit
- Related: OAR 918-281, Rough-In Inspection
A formal authorization issued by the building codes division or local jurisdiction allowing specific electrical work to proceed, subject to inspection and compliance with adopted codes.
- Rough-In Inspection
- Related: Electrical Permit, Final Inspection
An inspection conducted after electrical wiring and raceways are installed but before concealment by drywall or other finish materials, ensuring code compliance before the work is hidden.
- Final Inspection
- Related: Rough-In Inspection, Electrical Permit
The last inspection of an electrical installation, performed after all devices, fixtures, and equipment are installed and operational, to verify compliance before the system is approved for use.
- NFPA 70 National Electrical Code (NEC)
- Related: Oregon Electrical Specialty Code, Article 100
The model code for electrical installations in the United States, published by the National Fire Protection Association and adopted with amendments as the Oregon Electrical Specialty Code.
- Oregon Electrical Specialty Code
- Related: NFPA 70 National Electrical Code (NEC)
The Oregon-specific adoption of NFPA 70 with state amendments, governing the installation of electrical conductors, equipment, and systems within Oregon, including low voltage work.
- Article 100
- Related: Low Voltage, Limited Energy Circuit
The definitions article in NFPA 70 that establishes the meaning of technical terms used throughout the Code, including terms like 'low voltage' and 'limited energy circuit'.
- Low Voltage
- Related: Limited Energy Circuit, Article 100
A term generally referring to circuits operating at 50 volts or less, though specific definitions vary by code article; often used for signaling, control, and limited energy systems.
- Limited Energy Circuit
- Related: Low Voltage, Class 2 Circuit
A circuit that is power-limited and operates at voltages and currents below thresholds set by the NEC, allowing reduced wiring methods and materials compared to general-purpose circuits.
- Class 2 Circuit
- Related: Class 3 Circuit, Limited Energy Circuit
A circuit classified by the NEC as having limited power and voltage, typically not a shock hazard, and permitted to use less stringent wiring methods under Article 725.
- Class 3 Circuit
- Related: Class 2 Circuit
A circuit classified by the NEC as having higher energy than Class 2 but still limited, often used for signaling and control, with specific wiring and separation requirements under Article 725.
- Article 725
- Related: Class 2 Circuit, Class 3 Circuit
The NEC article covering Class 1, Class 2, and Class 3 remote-control, signaling, and power-limited circuits, including wiring methods, power sources, and separation requirements.
- Article 800
- Related: Communication Cable, Article 725
The NEC article governing communications circuits, such as telephone and data, including cable types, installation requirements, and protection against electrical hazards.
- Article 760
- Related: Fire Alarm Circuit, Class 2 Circuit
The NEC article covering fire alarm systems, including power-limited and non-power-limited fire alarm circuits, wiring methods, and equipment requirements.
- Fire Alarm Circuit
- Related: Article 760, Class 2 Circuit
A circuit that is part of a fire alarm system and is classified as either power-limited or non-power-limited, with specific installation and performance requirements under Article 760.
- Communication Cable
- Related: Article 800, Plenum Cable
A cable used for transmitting communication signals, such as twisted-pair or coaxial, and listed for the purpose, with specific markings and fire-resistance ratings.
- Plenum Cable
- Related: Riser Cable, Communication Cable
A cable with a jacket and insulation that has low smoke and flame spread characteristics, approved for installation in air-handling spaces without additional conduit.
- Riser Cable
- Related: Plenum Cable, Communication Cable
A cable designed for vertical installation in shafts between floors, with fire-resistant characteristics suitable for riser applications, as specified in NEC articles.
- Raceway
- Related: Conduit, Cable Tray
An enclosed channel designed for holding wires, cables, or busbars, such as conduit, tubing, or wireways, used to protect and route conductors.
- Conduit
- Related: Raceway, Cable Tray
A tubular raceway used to protect and route electrical conductors, available in metal or nonmetallic types, with specific installation and fill requirements.
- Cable Tray
- Related: Raceway, Conduit
A rigid structural system used to support and route cables, typically in industrial or commercial settings, with requirements for fill, support, and grounding.
- Grounding
- Related: Bonding, Ground Fault
The process of connecting electrical equipment and systems to the earth to limit voltage during faults or lightning, providing a reference and safety path.
- Bonding
- Related: Grounding, Equipment Grounding Conductor
The permanent joining of metallic parts to form an electrically conductive path that ensures electrical continuity and the capacity to conduct safely any current likely to be imposed.
- Equipment Grounding Conductor (EGC)
- Related: Grounding, Bonding
The conductive path installed to connect normally non-current-carrying metal parts of equipment together and to the system grounded conductor or grounding electrode conductor.
- Overcurrent Protection
- Related: Fuse, Circuit Breaker
A device or system that protects conductors and equipment from excessive current by automatically opening the circuit when current exceeds a predetermined value.
- Fuse
- Related: Circuit Breaker, Overcurrent Protection
An overcurrent protective device with a fusible element that melts and opens the circuit when current exceeds its rating, providing one-time protection.
- Circuit Breaker
- Related: Fuse, Overcurrent Protection
A reusable overcurrent protective device that automatically opens a circuit when current exceeds a set value and can be manually reset to restore power.
- Ground Fault
- Related: Grounding, Ground-Fault Circuit Interrupter (GFCI)
An unintentional electrical connection between a current-carrying conductor and ground, which can cause shock hazards and requires protection by grounding and ground-fault devices.
- Ground-Fault Circuit Interrupter (GFCI)
- Related: Ground Fault, Overcurrent Protection
A device that detects a difference between current in the hot and neutral conductors and opens the circuit to prevent electric shock from ground faults.
- Lockout/Tagout (LOTO)
- Related: Personal Protective Equipment (PPE), Voltage Tester
A safety procedure that involves locking and tagging energy-isolating devices to ensure equipment is de-energized before work, preventing accidental energization.
- Personal Protective Equipment (PPE)
- Related: Lockout/Tagout (LOTO), Voltage Tester
Equipment such as gloves, eye protection, and insulated clothing worn by workers to protect against electrical, physical, and environmental hazards on the job site.
- Voltage Tester
- Related: Lockout/Tagout (LOTO), Personal Protective Equipment (PPE)
A device used to verify the presence or absence of voltage in a circuit, essential for safety before working on electrical equipment.
- Multimeter
- Related: Voltage Tester
An electrical test instrument that measures voltage, current, and resistance, commonly used by low voltage technicians for troubleshooting and verification.
- Cable Jacket
- Related: Plenum Cable, Riser Cable
The outer protective covering of a cable, providing mechanical and environmental protection and often bearing markings that indicate the cable's type and rating.