OR Plumber study materials
OR Plumber study resources

OR Plumber cheat sheet

OR Plumber · Keep the key ideas within reach.

Quick reference

General Plumbing Knowledge

  • Water column pressure: 1 psi = 2.31 ft of water head; conversely 1 ft of head = 0.433 psi.

  • Fixture unit (FU) is a measure of probable drainage load, not a volume; 1 FU ≈ 1 gpm of drainage flow for sizing purposes.

  • Minimum practical slope for horizontal drainage pipe is 1/4 in per ft (2%) for pipe 3 in and smaller; 1/8 in per ft is allowed for 4 in and larger where the code permits.

  • Flow rate formula: Q = A × V; for a full circular pipe, Q (gpm) ≈ 0.0408 × d² (in) × V (ft/s).

  • Thermal expansion of water is roughly 4% by volume over a 40°F to 140°F rise; closed systems need an expansion tank or relief provision.

  • Standard atmospheric pressure at sea level is 14.7 psi; a perfect vacuum gauge reads 29.92 in Hg.

  • Copper tube type K is heaviest wall (underground), L is standard above-ground, M is lightest and often limited to exposed interior work.

  • Water weighs 62.4 lb per cubic ft; a cubic ft contains 7.48 gallons.

Quick reference

Plumbing Systems and Fixtures

  • Water closet flush volumes: 1.6 gpf standard since 1994; 1.28 gpf and 1.0 gpf high-efficiency models are common; Oregon follows the federal 1.6 gpf maximum.

  • Fixture trap seal depth is 2 in minimum and 4 in maximum; the trap weir must be below the fixture outlet.

  • Each fixture trap requires a vent unless it is a listed combination waste-and-vent or a code-recognized exception.

  • Air gap is the only backflow protection recognized for high-hazard, non-pressure connections; a 1 in minimum air gap is typical for most fixtures.

  • A lavatory drain is 1-1/4 in minimum; a water closet drain is 3 in; a bathtub drain is 1-1/2 in.

  • Floor drains require a trap primer or a trap seal protection device where the trap is subject to evaporation.

  • Shower valves must be pressure-balancing or thermostatic, with a maximum outlet temperature limit (typically 120°F) to prevent scalding.

  • Fixture clearances: water closet centerline at least 15 in from side walls and 21 in in front of the bowl.

Quick reference

Water Supply and Distribution

  • Minimum static pressure at a fixture is typically 8 psi for flush tanks and 15 psi for flushometer valves; maximum 80 psi requires a pressure-reducing valve.

  • Developed length includes pipe run plus equivalent lengths for fittings; a 90° elbow is often counted as 5–10 equivalent ft depending on size.

  • Sizing uses the fixture-unit method with the Hunter curves; convert FU to gpm, then select pipe size for the allowable velocity and pressure loss.

  • Recommended maximum velocity is 8 ft/s in cold water and 5 ft/s in hot water to limit noise and erosion.

  • Backflow prevention: an RPZ assembly is required for high-hazard, cross-connection-prone services such as irrigation and boiler feed.

  • Hot water distribution should maintain 110°F at fixtures; recirculation or heat-traced lines reduce wait time and waste.

  • Water service line size is determined by the building supply demand in FU plus the meter and street pressure; a 1 in service is common for a single-family dwelling.

  • Thermal expansion control: install a closed-system expansion tank downstream of the pressure-reducing valve or backflow preventer.

Quick reference

Drainage, Waste, and Vent Systems

  • Building drain is the lowest pipe receiving soil and waste inside the building; it extends to the building sewer, which begins 5 ft outside the foundation (Oregon terminology).

  • Vent stack sizing: a 1-1/2 in vent handles up to 8 FU; 2 in up to 24 FU; 3 in up to 48 FU (typical code table values - verify against the current Oregon table).

  • A wet vent may serve a limited number of fixtures on the same floor; the wet-vented branch must be sized per the code and connect to a dry vent above.

  • Horizontal drainage pipe must have cleanouts at intervals not exceeding 100 ft and at each change of direction greater than 45° in the building drain.

  • Trap arm length is limited to 5 ft for a 1-1/4 in trap arm and 6 ft for 1-1/2 in, with the vent connection at the trap weir.

  • A backwater valve is required where the building drain is below the level of the next upstream manhole or where the sewer can surcharge.

  • Vent terminal must extend at least 6 in above the roof and be at least 10 ft from an operable window or air intake.

  • Stack vent (also called a vent stack extension) is the continuation of a soil or waste stack above the highest fixture branch.

Quick reference

Oregon Plumbing Code and Regulations

  • Oregon adopts the Oregon Plumbing Specialty Code (OPSC), based on the Uniform Plumbing Code (UPC), administered by the Oregon Building Codes Division (BCD).

  • Plumbing work in Oregon requires a licensed plumber; a plumbing contractor license is separate from the individual journeyman or master plumber license.

  • Permits are required for new plumbing, alterations, and replacement of water heaters, fixtures, and drain lines; minor repairs may be exempt per OPSC.

  • The Oregon BCD issues licenses and administers continuing education; journeyman plumbers must complete continuing education hours per renewal cycle.

  • Inspections are performed by local jurisdictions or the state; the plumber must request inspection before concealing work.

  • Oregon requires backflow assembly testers to be certified and assemblies to be tested annually where required.

  • Water heater installation in Oregon must include a temperature-and-pressure relief valve piped to within 6 in of the floor or to a safe discharge point.

  • Oregon seismic requirements include strapping water heaters with two straps, one in the upper third and one in the lower third, and anchoring the base.