- General Duty Clause
- Section 5(a)(1) of the OSH Act requires each employer to furnish a workplace free from recognized hazards that are causing or are likely to cause death or serious physical harm.
- Eight-hour fatality reporting
- Employers must report a work-related fatality to OSHA within 8 hours, and an in-patient hospitalization, amputation, or loss of an eye within 24 hours.
- Construction standards Part 1926
- Construction work in the United States is regulated by OSHA under Title 29 of the Code of Federal Regulations, Part 1926, while general industry falls under Part 1910.
- Six-foot fall protection trigger
- Under 29 CFR 1926.501(b), construction employees exposed to falls of 6 feet or more to a lower level must be protected by a guardrail system, safety net, or personal fall arrest system.
- Guardrail height requirement
- The top edge of a guardrail system must be 42 inches, plus or minus 3 inches, above the walking surface, with a midrail located at approximately 21 inches.
- Personal fall arrest anchorage
- An anchorage for personal fall arrest must support at least 5,000 pounds per attached employee, or be designed with a safety factor of at least two by a qualified person.
- Hole cover strength
- Covers installed over floor holes must be secured against displacement and must be able to support at least twice the weight of employees, equipment, and materials placed on them.
- Struck-by flying object
- A struck-by flying object hazard comes from items such as nails, chips, or sparks driven through the air; safety glasses with side shields and hard hats are baseline protection.
- Swing radius barricade
- The rotating superstructure of a crane or excavator creates a struck-by and pinch hazard, so its swing radius must be barricaded to keep employees out of the area.
- Never under suspended load
- Employees are prohibited from working or walking beneath a suspended load; tag lines are used to control the load from a position outside the fall zone.
- Caught-in versus caught-between
- Caught-in or caught-between incidents cause injury by crushing, pinching, squeezing, or amputating a worker between parts of equipment, structures, or collapsing material such as a trench wall.
- Excavation protective system depth
- Trenches 5 feet or deeper require a protective system unless the competent person determines the excavation is in stable rock; shallower trenches must still be evaluated.
- Spoil pile set-back
- Excavated material, equipment, and stored supplies must be kept at least 2 feet back from the edge of a trench or excavation to reduce surcharge loading and collapse risk.
- GFCI on construction sites
- 29 CFR 1926.404 requires ground-fault circuit interrupters or an assured equipment grounding conductor program for all temporary 15- and 20-ampere receptacles on construction sites.
- Assume lines energized
- Overhead power lines are presumed energized until the serving utility confirms de-energization and visibly grounds the lines; equipment must stay outside minimum approach distances.
- Ten-foot rule for equipment
- For energized lines rated 50 kilovolts or below, equipment must maintain at least 10 feet of clearance unless the line is de-energized, grounded, or isolated as required.
- Lockout tagout verification
- De-energizing electrical equipment requires locking out the energy source, attaching a tag, and verifying the absence of voltage with a tester before any work begins.
- Employer-paid PPE
- 29 CFR 1926.95 requires employers to provide required personal protective equipment at no cost, except non-specialty safety-toe footwear and non-specialty prescription eyewear.
- Hard hat requirement
- Hard hats must be worn where employees are exposed to head injury from falling or flying objects, or from electrical shock or burns, as required by 29 CFR 1926.100.
- Respirator fit testing
- Employees required to use tight-fitting respirators must pass a medical evaluation, be fit tested at least annually, and be trained in proper use and limitations.
- Silica permissible exposure limit
- The construction silica standard, 29 CFR 1926.1153, sets a permissible exposure limit of 50 micrograms per cubic meter as an 8-hour time-weighted average, with an action level of 25.
- Hearing conservation trigger
- A hearing conservation program is required when noise exposure exceeds an 85 dBA 8-hour time-weighted average; the permissible exposure limit for construction is 90 dBA.
- Asbestos PEL construction
- 29 CFR 1926.1101 sets an asbestos permissible exposure limit of 0.1 fibers per cubic centimeter averaged over an 8-hour shift for construction work.
- Scaffold fall protection height
- Employees working on scaffolds 10 feet or more above a lower level must be protected by guardrail systems or by a personal fall arrest system.
- Ladder four-to-one rule
- Portable ladders must be set with the base 1 foot out from the vertical support for every 4 feet of working length, producing an angle of about 75 degrees.
- Extension ladder three-foot extension
- Extension ladders used for access must extend at least 3 feet above the landing surface, unless a grab rail or other adequate handhold is provided.
- Trench egress within 25 feet
- Trenches 4 feet or deeper must have a ladder, stairway, or ramp for egress positioned so that lateral travel from any worker to the exit is no more than 25 feet.
- Soil class maximum slopes
- Maximum allowable excavation slopes are 1.5 to 1 for Type A soil, 1 to 1 for Type B, and 0.75 to 1 for Type C; Type C soil must never be benched.
- Competent person daily inspection
- A competent person must inspect excavations and protective systems before each shift, after rainstorms, and after any event that could affect the stability of the excavation.
- Crane load chart limits
- A crane must never lift beyond the rated capacity listed on its load chart for the specific configuration, and capacity decreases as lifting radius and boom length increase.
- Crane power line approach
- Under 29 CFR 1926.1408, cranes must keep at least 20 feet from energized lines up to 350 kilovolts unless the line is de-energized, grounded, or isolated under an approved plan.
- Lumber stack height limit
- Stored lumber must not be stacked more than 20 feet high, and must not exceed 16 feet in height when the material is to be handled manually.