- General Duty Clause
- Section 5(a)(1) of the OSH Act requires employers to furnish a workplace free from recognized hazards that are causing or likely to cause death or serious physical harm.
- OSHA fatality reporting time
- An employer must report a work-related fatality to OSHA within 8 hours; an in-patient hospitalization, amputation, or loss of an eye must be reported within 24 hours.
- OSHA 300A posting period
- The annual summary of recordable injuries and illnesses, Form 300A, must be posted from February 1 through April 30 and retained with injury records for five years.
- 29 CFR 1910
- The portion of OSHA regulations containing general industry standards; construction standards appear in 29 CFR 1926 and maritime standards in 29 CFR 1915 through 1918.
- Fall protection trigger height
- In general industry, fall protection is required when employees are exposed to falls of 4 feet or more to a lower level; construction standards use a 6-foot trigger.
- Guardrail height
- A standard guardrail has a top rail at 42 inches, plus or minus 3 inches, above the walking surface, with a midrail at approximately 21 inches.
- Portable ladder setup
- Non-self-supporting ladders are set so the base is one-quarter of the working length from the wall, a 4:1 ratio, and extended 3 feet above the landing.
- Stair rail requirement
- Stairways with four or more risers need a stair rail system on each unprotected side or edge, and handrails are mounted 30 to 38 inches above the tread nosing.
- Minimum exit route width
- Exit routes must be at least 28 inches wide at all points, with capacity of 0.2 inch per occupant on level surfaces and 0.3 inch per occupant on stairways.
- Written EAP threshold
- An employer with more than 10 employees must have a written emergency action plan; employers with 10 or fewer may communicate the plan orally.
- Exit route ceiling height
- The ceiling of an exit route must be at least 7 feet 6 inches high, and no projection may reduce the route width below the required minimum.
- Fire prevention plan contents
- A fire prevention plan lists major fire hazards, handling and storage procedures, potential ignition sources, fire protection equipment, and housekeeping responsibilities for controlling accumulations of flammable waste.
- Guarding energized parts
- Live parts operating at 50 volts or more must be guarded by enclosures, partitions, location in a qualified-person-only room, or elevation at least 8 feet above the floor.
- Electrical working space
- At least 3 feet of clear working space is required in front of equipment rated 600 volts or less, and the space must be 30 inches wide and 6.5 feet high.
- GFCI protection
- Ground-fault circuit interrupter protection is required for temporary receptacles and wet or damp locations, and on construction sites for all 120-volt, 15- and 20-ampere outlets.
- Flexible cord restrictions
- Flexible cords may not substitute for fixed wiring and may not run through walls, ceilings, floors, or doorways, nor be attached to building surfaces.
- PPE hazard assessment
- The employer must assess workplace hazards, select appropriate personal protective equipment, and certify the written assessment identifying the workplace evaluated and the person certifying.
- Employer-paid PPE
- OSHA requires employers to pay for required PPE, except non-specialty safety-toe footwear and non-specialty prescription safety eyewear that employees may wear off the job.
- Hearing conservation threshold
- A hearing conservation program, including audiometric testing and hearing protection availability, is required when noise exposure reaches an 8-hour time-weighted average of 85 decibels.
- Respirator fit test
- Employees using tight-fitting respirators must pass a fit test before initial use and at least annually, and must complete a medical evaluation before fit testing.
- SDS section count
- A safety data sheet contains 16 sections in a fixed order; Section 2 covers hazard identification and Section 4 covers first-aid measures.
- GHS signal words
- Hazard communication labels use only two signal words: Danger for the more severe hazards and Warning for the less severe hazards, matched to the hazard category.
- HazCom written program
- Employers must prepare and maintain a written hazard communication program describing how labels, safety data sheets, and employee training will be implemented at that workplace.
- Secondary container labeling
- Portable containers filled from a labeled container must also be labeled, unless the material is used immediately by the employee who dispensed it within the same shift.
- Cylinder separation distances
- Oxygen and fuel gas cylinders must be separated by at least 20 feet or by a noncombustible barrier at least 5 feet high having a half-hour fire rating.
- Powered industrial truck evaluation
- Operators must be trained and evaluated, then re-evaluated at least once every three years; refresher training is required after unsafe operation or an accident.
- Storage stability rule
- Materials stored in tiers must be stacked, blocked, or interlocked and limited in height so they remain stable and secure against sliding or collapse.
- Clear aisles requirement
- Aisles and passageways must be kept clear and in good repair, and permanent aisles must be marked so stored materials never block access or egress.
- Machine guard requirements
- Guards must prevent body parts from contacting moving parts, be secure, create no new hazard, and not interfere with normal machine operation or lubrication.
- Abrasive wheel clearances
- On a bench or pedestal grinder, the work rest must be adjusted to within 1/8 inch of the wheel and the tongue guard within 1/4 inch of the wheel.
- Lockout tagout scope
- Hazardous energy control applies to servicing and maintenance when a guard must be removed or bypassed, or when a body part enters a machine danger zone.
- Power transmission guarding
- Pulleys, belts, gears, shafts, sprockets, and chains that form a machine's power transmission system must be guarded to prevent employee contact with moving parts.