OSHA 510 study materials
OSHA 510 study resources

OSHA 510 cheat sheet

OSHA 510 · Keep the key ideas within reach.

Quick reference

OSHA Act, General Industry vs. Construction, and 1926 Subpart C

  • OSHA Act Section 5(a)(1), the General Duty Clause, requires employers to furnish a workplace free of recognized hazards likely to cause death or serious physical harm when no specific standard applies.

  • Section 5(a)(2) obligates employers to comply with specific OSHA standards; Section 5(b) binds employees to comply with rules and orders applicable to their own conduct.

  • 29 CFR 1926 governs construction, defined in 1910.12(b) as work for construction, alteration, and/or repair, including painting and decorating; 29 CFR 1910 covers general industry.

  • Where a construction activity is not addressed by a 1926 standard, 1926.20(a)(1) requires compliance with applicable 1910 standards; Subpart C is the fallback gateway.

  • 1926.20(b)(1)-(2) require a safety and health program and frequent, regular job site inspections by a competent person designated by the employer.

  • 1926.21(b)(2) requires training for employees exposed to unsafe conditions, with recognition of hazards and avoidance procedures; 1926.21(b)(1) covers first aid and medical services.

  • 1926.33 adopts 1910.1020 access to employee exposure and medical records; 1926.34 requires exit routes kept unobstructed and marked.

  • 1926.35 requires a written emergency action plan for sites with more than 10 employees, and an oral plan communicated to all employees for 10 or fewer.

  • 1926.23 and 1926.24 cover first aid supplies and fire protection/PPE obligations respectively, coordinating Subpart C with Subparts E and F.

Quick reference

29 CFR 1926 Subparts D-F: Occupational Health, PPE, Fire Protection

  • 1926.52 Table D-1 permissible noise exposures: 90 dBA for 8 hours, 95 dBA for 4, 100 dBA for 2, 105 dBA for 1, 110 dBA for 0.5, 115 dBA for 0.25 hour; a 5 dBA increase halves allowable duration.

  • 1926.55 adopts ACGIH TLVs as advisory limits for air contaminants; 1926.57 covers ventilation for abrasive blasting and spray operations.

  • 1926.59 adopts 1910.1200 Hazard Communication; 1926.62 lead and 1926.1126 chromium (VI) set action levels and exposure limits for construction.

  • 1926.95 requires PPE provided, used, and maintained in sanitary, reliable condition at no cost to employees; 1926.96 covers occupational foot protection.

  • 1926.100 head protection required where falling objects or electrical hazards exist; 1926.101 hearing protection required at exposure above limits in 1926.52.

  • 1926.102 eye and face protection must comply with ANSI Z87.1 and be provided when machines or operations present eye or face injury hazards.

  • 1926.103 respiratory protection adopts 1910.134, requiring a written program, medical evaluation, fit testing, and training.

  • 1926.150 fire protection requires a firefighting program; 1926.152 governs flammable liquids storage; 1926.151 addresses ignition hazards.

  • 1926.150(c)(1) requires at least one 2A-rated extinguisher per 3,000 square feet of protected building area, with travel distance not exceeding 100 feet.

Quick reference

29 CFR 1926 Subparts G-H: Signs, Signals, Barricades; Materials Handling

  • 1926.200(a) requires accident prevention signs where hazards exist, with signal words DANGER (immediate danger), WARNING (potential hazard), CAUTION (minor hazard), and NOTICE (non-hazard information).

  • 1926.201 signaling by flaggers uses red flags at least 24 inches square; 1926.202 barricades must conform to the Manual on Uniform Traffic Control Devices.

  • 1926.200(g) requires traffic control signs to conform to MUTCD; 1926.203 defines standard accident prevention signs and tags.

  • 1926.250(a) requires materials stored so that they are stable and secure against sliding or collapse, with clearance maintained for aisles and passageways.

  • 1926.250(b)(2) limits stacks of bagged materials to a height that maintains stability; 1926.250(b)(5) requires stacked materials to be kept clear of walls.

  • 1926.250(b)(8) requires materials stored in tiers to be stacked, blocked, interlocked, and limited in height to prevent sliding or collapse.

  • 1926.251 governs rigging equipment: slings inspected before use, removed from service if defective, and marked with rated capacity.

  • 1926.252 requires disposal of waste materials by removal from the site at frequent intervals; 1926.252(e) covers waste handling in multi-story structures.

  • 1926.252(c) requires enclosed chutes for dropping material more than 20 feet, with an opening not exceeding 45 degrees from horizontal.

Quick reference

29 CFR 1926 Subparts I-K: Hand and Power Tools, Welding, Electrical

  • 1926.300(a) requires tools to be maintained in safe condition; 1926.300(b)(1) requires guards on moving parts of power tools that expose employees to injury.

  • 1926.301 requires hand tools to be inspected before use and removed from service if defective; 1926.302 covers power-operated hand tools, including electric and powder-actuated tools.

  • 1926.302(e) requires powder-actuated tools to be operated only by trained, certified employees, with eye protection and loading after the tool is pointed.

  • 1926.303 requires abrasive wheels to be inspected and ring-tested before mounting; 1926.304 covers woodworking tools and 1926.305 jacks.

  • 1926.350 covers gas welding and cutting; 1926.350(a)(10) requires cylinders kept upright and secured; 1926.350(b) covers oxygen-fuel gas storage and separation.

  • 1926.351 covers arc welding and cutting; 1926.352 governs fire prevention, requiring removal of combustibles or use of guards and shields.

  • 1926.353 requires ventilation for welding in confined spaces; 1926.354 covers welding, cutting, and heating in way of preservative coatings.

  • 1926.400-1926.408 cover electrical: 1926.403 requires approved electrical conductors and equipment; 1926.404 covers wiring design and protection.

  • 1926.405 governs wiring methods, components, and equipment; 1926.406 covers specific-purpose equipment; 1926.407 covers hazardous locations.

  • 1926.416(a) requires protection of employees from electrical hazards, including de-energizing and lockout; 1926.417 covers lockout and tagging of circuits.

Quick reference

29 CFR 1926 Subpart L: Scaffolds

  • 1926.451(a)(1) requires each scaffold and scaffold component to support its own weight and at least 4 times the maximum intended load without failure.

  • 1926.451(a)(4) requires access to scaffold platforms; 1926.451(e) requires ladders, stair towers, or ramps, and prohibits climbing cross braces.

  • 1926.451(b)(1) requires platform units to be fully planked or decked between the front uprights and guardrail supports, with limited exceptions.

  • 1926.451(b)(3) limits gaps between platforms and uprights to 1 inch; 1926.451(b)(4) requires platforms to be overlapped or secured against movement.

  • 1926.451(c) requires scaffolds to be braced, guyed, or tied to prevent tipping; 1926.451(d) covers suspension scaffold support devices.

  • 1926.451(f) covers use: scaffolds must not be loaded beyond rated capacity, and employees must not work on scaffolds during storms or high winds.

  • 1926.451(g) requires guardrail systems or personal fall arrest for employees on platforms more than 10 feet above a lower level.

  • 1926.452 covers specific scaffold types, including mobile, tube and coupler, and suspension scaffolds; 1926.453 covers aerial lifts.

  • 1926.454 requires training for employees who perform work on scaffolds, covering hazards, load capacities, and fall protection, with retraining when necessary.

Quick reference

29 CFR 1926 Subpart M: Fall Protection

  • 1926.501(b)(1) requires fall protection for employees on walking/working surfaces with an unprotected side or edge 6 feet or more above a lower level.

  • 1926.501(b)(4) requires protection from falling through holes, including covers secured and marked; 1926.502(i) covers hole covers.

  • 1926.501(b)(13) requires residential construction fall protection at 6 feet, or a written fall protection plan under 1926.502(k) for specified activities.

  • 1926.502(b) requires guardrail systems with top rail at 42 inches plus or minus 3 inches and midrail at approximately 21 inches, capable of 200 pounds.

  • 1926.502(d) requires personal fall arrest systems to limit maximum arresting force to 1,800 pounds and arrest a fall within 3.5 feet.

  • 1926.502(d)(16) requires prompt rescue of employees in the event of a fall or assurance of self-rescue; 1926.502(d)(19) requires anchorage at 5,000 pounds or twice the expected load.

  • 1926.502(f) covers warning line systems at 6 feet or more from the edge, with lines 34 to 39 inches high and 500-pound strength.

  • 1926.502(h) covers safety monitoring systems, requiring a competent person to monitor and warn employees, with no other duties assigned.

  • 1926.503 requires fall protection training, with retraining when there is reason to believe the employee lacks understanding or skill.

Quick reference

29 CFR 1926 Subparts N-O: Cranes, Derricks, Hoists; Motor Vehicles and Equipment

  • 1926.1400 scope covers power-operated equipment used to hoist, lower, and horizontally move a suspended load, with exclusions listed in 1926.1400(c).

  • 1926.1417 requires equipment to be operated only by a qualified operator and in accordance with the manufacturer's procedures and load charts.

  • 1926.1419 covers signals; 1926.1420 covers signal person qualifications; 1926.1421 covers voice signals.

  • 1926.1423 covers fall protection for crane personnel; 1926.1424 covers work area control; 1926.1425 covers keeping clear of the load.

  • 1926.1427 requires operator qualification or certification, with evaluation and licensing requirements; 1926.1431 covers hoisting personnel.

  • 1926.1433 covers safety devices, including operational aids such as load moment indicators and anti-two-block devices.

  • 1926.1441 covers equipment with a rated hoisting/lifting capacity of 2,000 pounds or less.

  • 1926.600 covers motor vehicles and mechanized equipment: 1926.601 requires seat belts in vehicles; 1926.602 covers earthmoving equipment.

  • 1926.602(a)(9) requires audible alarms on earthmoving equipment when operated in reverse; 1926.604 covers site clearing; 1926.605 covers marine operations.

Quick reference

29 CFR 1926 Subpart P: Excavations

  • 1926.650 defines a competent person as one capable of identifying existing and predictable hazards and authorized to take prompt corrective measures.

  • 1926.651(b) requires underground installations to be located and protected before excavation; 1926.651(c) covers access and egress.

  • 1926.651(c)(2) requires a stairway, ladder, ramp, or other safe means of egress in trench excavations 4 feet or more deep, within 25 feet of lateral travel.

  • 1926.651(g) requires testing for oxygen deficiency and hazardous atmospheres in excavations 4 feet or more deep where a hazardous atmosphere could exist.

  • 1926.651(i) requires excavated materials and equipment kept at least 2 feet from the edge of the excavation.

  • 1926.652(a)(1) requires protective systems for excavations 5 feet or more deep, unless the excavation is entirely in stable rock.

  • 1926.652(b) permits sloping, benching, shoring, or shielding; 1926.652(c) requires protective system design by a registered professional engineer for certain conditions.

  • 1926.651(k) requires daily inspections by a competent person before work begins and as needed throughout the shift, and after rainstorms or other hazard-increasing events.

  • 1926.651(j) requires protection from loose rock or soil and removal of excavated material that could fall into the excavation.

Quick reference

29 CFR 1926 Subparts Q-X: Concrete, Steel, Underground, Demolition, Blasting, Power Transmission, ROPS, Ladders

  • 1926.701 covers concrete construction: 1926.701(b) prohibits construction loads on a concrete structure unless the employer determines the structure can support them.

  • 1926.702 covers equipment and tools; 1926.703 covers cast-in-place concrete, including formwork design by a qualified person.

  • 1926.750-1926.761 cover steel erection; 1926.754 covers structural steel assembly; 1926.760 requires fall protection at 15 feet for steel erection.

  • 1926.751 requires a site-specific erection plan for certain steel erection activities; 1926.752 covers site layout and construction sequence.

  • 1926.800 covers underground construction, including air quality, communication, and check-in/check-out procedures for employees underground.

  • 1926.850-1926.859 cover demolition: 1926.850 requires an engineering survey by a competent person before demolition begins.

  • 1926.851 covers stairs, passageways, and ladders; 1926.852 covers chutes; 1926.853 covers removal of materials through floor openings.

  • 1926.900-1926.914 cover blasting: 1926.900 requires blasting conducted by qualified persons and warning signals; 1926.909 covers firing precautions.

  • 1926.950-1926.960 cover power transmission and distribution; 1926.960(c) requires minimum approach distances to energized lines.

  • 1926.1000-1926.1003 cover rollover protective structures; 1926.1050-1926.1060 cover stairways and ladders, including 1926.1053 ladder requirements and 1926.1060 training.

Quick reference

29 CFR 1926 Subpart Z: Toxic and Hazardous Substances, HazCom, Silica

  • 1926.1101 covers asbestos, with permissible exposure limits and required work practices for construction activities; 1926.1103 covers 13 carcinogens.

  • 1926.1126 covers chromium (VI), with a permissible exposure limit of 5 micrograms per cubic meter as an 8-hour TWA.

  • 1926.1127 covers cadmium; 1926.1152 covers respirable crystalline silica in construction, with a PEL of 50 micrograms per cubic meter as an 8-hour TWA.

  • 1926.1153 requires engineering controls, including wet methods or dust collection, and specifies Table 1 tasks with required controls.

  • 1926.1153(g) requires a written exposure control plan, designated competent person, and employee training on silica hazards.

  • 1926.1153(i) requires medical surveillance for employees exposed at or above the action level of 25 micrograms per cubic meter for 30 or more days per year.

  • 1926.59 adopts 1910.1200 Hazard Communication, requiring labels, safety data sheets, and training for employees exposed to hazardous chemicals.

  • 1926.55 adopts ACGIH threshold limit values as advisory limits for air contaminants; 1926.60 covers methylenedianiline; 1926.61 covers 1,3-butadiene.

  • 1926.62 covers lead, with an action level of 30 micrograms per cubic meter as an 8-hour TWA and a PEL of 50 micrograms per cubic meter.

Quick reference

Safety and Health Program Concepts and Recordkeeping/Injury Reporting

  • A safety and health program typically includes management leadership, worker participation, hazard identification and assessment, hazard prevention and control, education and training, and program evaluation.

  • Hazard control follows the hierarchy of controls: elimination, substitution, engineering controls, administrative controls, and personal protective equipment.

  • 1926.20(b)(2) requires frequent and regular inspections of job sites, materials, and equipment by a competent person as part of the safety program.

  • 1926.21(b)(2) requires employee training on hazard recognition and avoidance procedures; 1926.35 requires emergency action plans.

  • 29 CFR 1904 requires recording of work-related fatalities, injuries, and illnesses; 1904.39 requires reporting fatalities within 8 hours and in-patient hospitalizations, amputations, or eye loss within 24 hours.

  • 1904.32 requires annual summary (OSHA Form 300A) posting from February 1 to April 30; 1904.29 covers forms 300, 301, and 300A.

  • 1904.7 defines a recordable case as one resulting in death, days away from work, restricted work or transfer, medical treatment beyond first aid, loss of consciousness, or significant injury/illness diagnosis.

  • 1904.5 covers work-relatedness, including the presumption that injuries in the work environment are work-related and exceptions for members of the public and personal tasks.

  • 1904.41 requires electronic submission of injury and illness information for establishments meeting size and industry criteria.