Fire Officer Exam (FOE) flashcards
Fire Officer Exam (FOE) · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Span of control
- The number of subordinates one supervisor can effectively manage; in incident command the recommended range is three to seven, with five considered optimal.
- POSDCORB
- A management acronym for planning, organizing, staffing, directing, coordinating, reporting, and budgeting, used to describe administrative functions in a fire department.
- Zero-based budgeting
- A budget method that requires each program or expenditure to be justified from a zero base every budget cycle rather than using the prior year's budget as the starting point.
- Garrity rights
- Protections for public employees subjected to compelled investigative statements; such statements cannot be used against the employee in a criminal proceeding, though administrative use is allowed.
- Weingarten rights
- A unionized employee's right to have a union representative present during an investigatory interview that the employee reasonably believes may result in discipline.
- Loudermill hearing
- A public employee's due-process right to notice of charges and an opportunity to respond before being deprived of a property interest such as continued employment.
- Occupant load
- The computed number of people a building or area is designed to hold, based on floor area and use, used to size exits, egress, and life-safety features.
- Knox box
- A secure key box mounted at a building entrance that allows fire personnel to access keys or controls during an emergency, reducing forced entry and delay.
- Certificate of occupancy
- A document issued by the code authority confirming that a building complies with applicable codes and may be occupied for its approved use.
- Fire cause classifications
- The four standardized cause categories are accidental, natural, incendiary, and undetermined; the classification reflects the investigation's best-supported determination.
- NFPA 921
- A guide for fire and explosion investigations that describes the scientific method, origin and cause analysis, fire patterns, and documentation practices used by investigators.
- Chain of custody
- A documented record of who collected, handled, transferred, and stored evidence, used to show that evidence has not been altered or contaminated.
- RECEO-VS
- A tactical sequence: Rescue, Exposures, Containment, Extinguishment, Overhaul, Ventilation, and Salvage; it organizes fireground priorities, though ventilation may occur earlier when coordinated.
- Iowa fire flow formula
- The Iowa fire flow formula estimates needed fire flow in gallons per minute as 100 times the square root of building volume in cubic feet divided by 100.
- Defensive fire strategy
- A tactic that operates from outside the structure, often using master streams, when savable life or property is not achievable or collapse risk makes interior operations too dangerous.
- Unified Command
- An incident command arrangement in which multiple agencies with jurisdiction or responsibility jointly set objectives and coordinate action without relinquishing their own authority.
- NIMS
- The National Incident Management System provides a consistent nationwide framework for command, communications, resource management, preparedness, and coordinated response across all responders.
- ADDIE model
- An instructional design model with five phases: analysis, design, development, implementation, and evaluation; it provides a systematic approach to building training.
- Kirkpatrick levels
- Four training evaluation levels: reaction, learning, behavior, and results; they measure satisfaction, knowledge gain, on-the-job performance, and organizational outcomes.
- NFPA 1041
- The standard for fire service instructor professional qualifications; it defines instructor levels, knowledge, and skills for delivering fire service training.
- Emergency Response Guidebook
- A guidebook for initial response to hazardous materials incidents, organized by yellow identification number, blue material name, orange response guide, and green isolation distances.
- Hot zone
- The contaminated area at a hazardous materials incident where only personnel in appropriate protective equipment and with established control operate.
- Level A PPE
- The highest chemical protective ensemble, providing vapor-tight encapsulation with self-contained breathing apparatus, used when skin or respiratory exposure to vapors is high.
- Type IV construction
- Heavy timber construction using large solid or laminated wood members with limited concealed spaces and required fire-resistance ratings; common in older mills and warehouses.
- Flashover
- The transition to full-room fire involvement when heat feedback ignites most combustible surfaces nearly simultaneously; typical gas temperatures approach 1,100°F (600°C).
- Class I standpipe
- A standpipe system with 2.5-inch connections intended for fire department use, typically located in stairwells of buildings where hose lines cannot reach upper floors easily.
- START triage
- Simple Triage and Rapid Treatment sorts patients by respirations, perfusion, and mental status into immediate, delayed, minor, and deceased categories.
- CPR compression rate
- Adult chest compressions should be delivered at 100 to 120 per minute with a depth of at least 2 inches and no more than 2.4 inches.
- Tourniquet
- A device applied proximal to a life-threatening extremity hemorrhage to occlude arterial flow; it should be tightened until bleeding stops and the time recorded.
- Five E's
- A prevention framework: education, enforcement, engineering, environment, and emergency response; it guides community risk reduction strategies across multiple approaches.
- Community risk reduction
- A process that identifies local risks, prioritizes them using data, and implements integrated strategies to reduce injury, death, and property loss.
- Smoke alarm replacement
- Smoke alarms should be tested monthly and replaced every 10 years or per manufacturer instructions; ionization and photoelectric types detect different fire conditions.