Fixture unit (FU)
A unit of measure expressing the load-producing effect of a plumbing fixture on the drainage or water supply system, used to size pipes and vents.
Trap arm length rule
The developed length of a trap arm must be at least twice its diameter, and its fall must not exceed one pipe diameter, to prevent self-siphonage.
Air gap backflow protection
An unobstructed vertical distance through free atmosphere between a water outlet and the flood-level rim of a receptor, at least twice the effective opening and never less than one inch.
Soil pipe vs. waste pipe
A soil pipe carries sewage containing fecal matter from water closets and urinals; a waste pipe carries non-fecal liquid waste from sinks, lavatories, and tubs.
Cleanout location requirement
A cleanout is required at the base of each soil or waste stack, at the upper end of horizontal drains, and at intervals not exceeding 15 meters in long horizontal runs.
Vent stack sizing basis
Vent stack diameter is selected from the total fixture units connected and the stack length, using code tables that limit the FU load per vent size.
RPZ backflow assembly
A reduced-pressure-zone assembly uses two check valves and a differential relief valve to protect against both backpressure and backsiphonage in high-hazard cross-connections.
Drainage pipe slope rule
Horizontal drainage pipe 3 inches and smaller slopes at 1/4 inch per foot; 4 inches and larger slopes at 1/8 inch per foot; no drainage pipe may slope less than 1/8 inch per foot.
Minimum water service size
A single-family dwelling water service must be at least 3/4 inch nominal size, with residual pressure at fixtures of at least 8 psi and not more than 80 psi.
Vent termination requirements
A vent must extend at least 6 inches above the roof, be at least 3 feet from windows or air intakes, and at least 10 feet from a property line or adjoining building.
Water heater T&P valve
A temperature-pressure relief valve is required on every water heater and must be piped full-size to a safe discharge, terminating not more than 6 inches above the floor or outside.
Backwater valve purpose
A backwater valve is installed on a building drain or fixture drain subject to sewer backflow, allowing flow out but closing against reverse flow into the building.
Grease interceptor sizing
A grease interceptor for commercial kitchens is sized by the fixture flow rate and required grease retention capacity, and must be installed outside or readily accessible for cleaning.
Water closet drain size
A water closet must connect to a drain of at least 3 inches diameter, with a 3-inch closet bend and a stack of at least 3 inches to carry its 3 fixture units.
Residual pressure at fixtures
The minimum residual flowing pressure at a plumbing fixture is 8 psi, and the maximum static pressure is 80 psi unless a pressure-reducing valve is installed.
PVC vs. CPVC use
PVC is used for cold water and drain-waste-vent piping; CPVC is rated for hot and cold water up to about 180°F (82°C).
Copper tube types K, L, M
Type K copper is thickest and used underground; Type L is standard for water service; Type M is thinnest and used only above ground.
No-hub cast iron coupling
A no-hub coupling joins cast iron soil pipe with a rubber sleeve and stainless steel clamp, tightened to about 60 inch-pounds of torque.
Sanitary tee fitting
A sanitary tee has a curved branch that directs flow from vertical to horizontal drainage, minimizing turbulence and preventing waste from entering the vent.
P-trap water seal
A P-trap retains a water seal of 2 to 4 inches, which blocks sewer gas from entering the building while allowing waste to pass through.
Flushometer supply requirement
A flushometer water closet requires a minimum 1-inch supply and about 15 to 25 psi flowing pressure, compared with 1/2 inch and 8 psi for a tank-type closet.
Vitreous china fixtures
Vitreous china is a glazed ceramic material used for water closets, lavatories, and urinals because it is hard, non-porous, and easy to clean.
Wye and 1/8 bend use
A wye fitting with a 1/8 bend is used for horizontal-to-horizontal drainage connections, providing a smooth sweep that reduces clogging.
Water hammer arrestor
A water hammer arrestor is a device with a trapped air chamber or piston installed near quick-closing valves to absorb pressure surges in the piping system.
Schedule 40 vs. Schedule 80
For the same nominal size, Schedule 80 PVC has thicker walls and a higher pressure rating than Schedule 40, which in turn is stronger than Schedule 20.
R.A. 1378 Plumbing Law
Republic Act 1378 regulates plumbing practice in the Philippines, creating the Board of Master Plumbers under the PRC and requiring registration to practice.
Master plumber seal requirement
Only a registered master plumber may sign and seal plumbing plans and specifications, and the PRC license number must appear on drawings submitted for permit.
Plumbing permit process
A plumbing permit must be secured from the local building official before installation, and a certificate of final inspection is issued after completion and inspection.
CPD requirement for renewal
Under R.A. 10912, licensed professionals must earn continuing professional development units set by the PRC to renew their professional identification card.
Conflict of interest disclosure
A master plumber with a financial interest in a supplier or contractor must disclose it in writing; failure to disclose violates the code of ethics.
Grounds for license revocation
Practicing without a license, falsifying plans, or allowing another person to use one's seal are grounds for suspension or revocation by the PRC Board.
Contract documents in plumbing
The owner-plumber agreement should state scope, drawings, specifications, payment terms, and warranty, with any verbal changes confirmed in writing.