Plumbing NC I study materials
Plumbing NC I study resources

Plumbing NC I cheat sheet

Plumbing NC I · Keep the key ideas within reach.

Quick reference

Workplace Communication and OHS Practices

  • Hierarchy of hazard control, in order of preference: elimination, substitution, engineering controls, administrative controls, then PPE. PPE is the last line of defence.

  • Personal protective equipment for plumbing work: safety helmet, safety footwear, eye/face protection, hearing protection above 85 dB(A), gloves matched to the chemical, and respiratory protection for dust, solvent vapour, or sewage aerosols.

  • A confined space is any space not designed for continuous occupancy with restricted entry or exit; entry requires a permit, atmospheric testing (oxygen 19.5-23.5%), a standby person, and rescue arrangements.

  • Hydrogen sulfide (H2S) is heavier than air and deadens the sense of smell at higher concentrations; never rely on odour as a warning in sewers or pits.

  • Isolation before work on piping: lockout/tagout, depressurize, drain, vent, and verify zero energy. Water at 1 bar exerts roughly 100 kPa; trapped thermal expansion can raise pressure many times higher.

  • Manual handling rule of thumb: keep the load close to the body, bend the knees, avoid twisting; two-person lift or mechanical aid for loads above about 25 kg.

  • Emergency response sequence: raise the alarm, make the area safe if it is safe to do so, give first aid within your training, then report and record the incident.

  • Communication on site: take and confirm instructions back, use a permit-to-work for hot work and confined spaces, and record verbal changes in writing.

  • Hand signals and tag lines for crane or excavator lifts: one designated signaller only; stop signal is valid from anyone at any time.

Quick reference

Hand Tools, Power Tools, and Plumbing Equipment

  • Pipe wrench: place the jaws so that pulling force drives the teeth into the pipe; the hook jaw adjusts to the work direction. Never use a cheater bar or hammer on the handle.

  • Stilson-type wrench capacity is marked on the handle; a wrench that is too large will slip and round the pipe.

  • Hacksaw blade selection: 18 teeth per inch for thick-wall steel and copper, 24-32 TPI for thin-wall tube and plastic; at least three teeth must be in contact with the work.

  • Files cut on the forward stroke; a bastard cut removes material fast, a smooth cut finishes. Clean the file with a card file, never by striking it.

  • Power drill safety: clamp the work, use the correct bit for the material, let the bit cool, and never wear loose gloves or sleeves near a rotating chuck.

  • Threading machine and power bender: check the guard and the emergency stop before use, keep hands clear of the die head and the bending shoe, and support long stock at both ends.

  • Pressure testing equipment: a hand pump with a calibrated gauge; test gauges must be within their valid calibration period and rated above the test pressure.

  • Soldering and brazing gear: use a lead-free solder for potable water, keep flux off skin, and ventilate; brazing filler melts above 450 degrees C, soldering below it.

  • Tool inspection before use: check insulation on portable electric tools, test RCD/GFCI protection, and remove damaged tools from service with a tag.

Quick reference

Plumbing Plans, Drawings, and Specifications

  • Drawing scales: 1:50 means one unit on the drawing equals 50 units on site; measure with the stated scale bar, not an assumed one.

  • Plan, elevation, and section views work together; a plan shows layout in the horizontal plane, an elevation shows heights, a section shows concealed construction.

  • Line conventions: solid lines are visible work, dashed lines are hidden, centre lines are long-short-long, and a break line shows omitted length.

  • Sanitary and drainage drawings use gravity-flow slopes, expressed as a ratio (1:60) or as a fall in mm per metre; confirm the slope on the drawing before setting out.

  • Riser diagrams are schematic, not to scale; they show pipe sizes, fixture connections, vents, and floor levels, not horizontal distances.

  • Specifications govern material, jointing method, testing, and standards; where a drawing and a specification conflict, raise a request for information rather than choosing one.

  • Title block and revision table: check the drawing number, revision letter, date, and approval status before setting out or cutting.

  • Isometric drawings show a single pipe route in three dimensions with true lengths along each axis; they are used for fabrication and material take-off.

  • Symbols to recognize: gate valve, check valve, pressure-reducing valve, floor drain, trap, vent stack, water heater, and stopcock; a legend on the sheet defines the project symbols.

Quick reference

Measurement, Layout, and Material Take-Off

  • Unit conversions: 1 inch = 25.4 mm; 1 foot = 0.3048 m; 1 gallon (US) = 3.785 L; 1 psi is approximately 6.895 kPa; 1 bar = 100 kPa.

  • Pipe sizes are nominal; the outside diameter of steel pipe is fixed for a given nominal size, while the inside diameter changes with wall thickness (schedule).

  • Take-off quantity = measured length plus allowance for fittings, offsets, and waste. Add a waste allowance of about 5 percent for straight runs and 10 percent for complex fabrication.

  • True length of an offset: for a 45-degree offset, the travel equals the offset multiplied by 1.414, and the fitting allowance is subtracted for each 45-degree elbow.

  • Centre-to-centre measurement between fittings is converted to cut length by subtracting the fitting take-out (centre-to-face dimension) at each end.

  • Fall calculation: fall = length multiplied by gradient. A 12 m run at 1:60 falls 12 divided by 60 = 0.2 m, or 200 mm.

  • Volume of a pipe or tank: volume = cross-sectional area multiplied by length; for a cylinder, area = pi multiplied by radius squared.

  • Setting out: establish a datum level and a reference line first, transfer levels with a water level or laser, and check square with the 3-4-5 method.

  • Marking: use a wrap-around or a pipe square for square cuts on round pipe; a freehand line will produce an out-of-square end and a failed joint.

Quick reference

Pipe Cutting, Threading, Bending, and Joining

  • Copper tube cutting: use a wheel cutter and deburr both inside and outside; a burr left inside disturbs flow and can cause erosion-corrosion.

  • Solder joint sequence: clean to bright metal, apply flux thinly, assemble with a capillary gap, heat the fitting evenly, and feed solder until a full ring appears at the joint.

  • Brazing uses filler melting above 450 degrees C with a flux or a self-fluxing alloy; it produces a stronger joint than soft soldering and is used for higher temperatures and pressures.

  • Threaded steel pipe: standard taper is 1:16 (about 1.8 degrees), giving roughly 3 threads engagement by hand and 5 to 6 threads when tightened with a wrench.

  • Cut threads must be lubricated with cutting oil, cleaned, and protected with jointing compound or PTFE tape applied in the direction of thread engagement.

  • Solvent-welded plastic pipe: cut square, chamfer, clean with primer, apply cement to both surfaces, assemble with a quarter turn, and hold until set; cure time depends on diameter and temperature.

  • Push-fit and compression fittings: the pipe must be cut square, inserted to the marked depth, and the compression nut tightened by hand then about one turn with a wrench.

  • Pipe bending: minimum bend radius depends on the material and the bender; for a 90-degree bend, the gain equals twice the radius minus the developed arc, and must be allowed for in the cut length.

  • Grooved and mechanical couplings allow jointing without heat or thread; the pipe end must be cut square and the groove rolled to the coupling manufacturer's dimension.

Quick reference

Water Supply, Sanitary, and Drainage Piping Systems

  • Direct water supply feeds from the mains; indirect supply feeds from a storage tank. Many codes require indirect supply where backflow risk or interruption is a concern.

  • Backflow prevention: an air gap is the highest protection, followed by a reduced-pressure zone assembly, then a double check valve; a simple check valve is not adequate for high hazard.

  • Water hammer is controlled with air chambers, surge arrestors, or slow-closing valves; it is caused by sudden velocity change in the line.

  • Drainage is gravity flow with a continuous air path: every fixture trap is protected by a vent, and the vent stack terminates above the roof.

  • Trap seal depth is typically 50-75 mm; a shallow seal evaporates and a deep seal is hard to clear. Trap arms have a maximum developed length that depends on pipe size.

  • Drainage pipe slope: 1:60 to 1:40 for small-bore branch drains is common; too little slope causes solids deposition, too much slope leaves liquids behind the solids.

  • A building drain carries waste to the building sewer; a soil pipe carries sewage, a waste pipe carries other discharge, and a vent pipe carries air only.

  • Testing: water supply is pressure tested at typically 1.5 times working pressure for a set period; drainage is tested by water test or air test before concealment.

  • Pipe support spacing depends on material and diameter; plastic pipe needs more supports than steel because of thermal expansion, and expansion loops or offsets are provided.

Quick reference

Plumbing Fixtures and Appurtenances

  • Fixture setting: check the rough-in dimensions on the drawing, set the fixture level, secure to framing or floor, and connect with a trap that is accessible for cleaning.

  • Water closet types: close-coupled, washdown, siphon, and flush valve; flush valve installations need a minimum supply pressure and flow stated by the manufacturer.

  • Faucets and mixers: install with the hot on the left and cold on the right; a thermostatic mixing valve limits delivery temperature at the outlet.

  • A pressure-reducing valve is set to the required downstream pressure, typically about 300-500 kPa; install a strainer upstream and an expansion relief downstream where the system is closed.

  • Floor drains require a trap primer where the trap would otherwise dry out; a trap that has lost its seal allows sewer gas into the building.

  • Water heaters: fit a temperature and pressure relief valve, discharge it to a safe place, and provide an expansion vessel or relief on a closed system.

  • Fixture maintenance: replace washers and cartridges with the correct size, clean aerators and strainers, and test for leaks at the supply and waste connections after reassembly.

  • Accessibility: grab bars must be anchored into structure or blocking, not into drywall alone; accessible fixtures have specified mounting heights and clear floor space.

  • Commissioning: flush the lines, check flow and temperature at each outlet, verify no leaks at traps and valves, and record test results before handover.