- PPE for solvent cement work
- Safety glasses or goggles, gloves resistant to solvent, and a respirator with organic vapor cartridges in poorly ventilated areas. Primer and cement are flammable, so keep ignition sources away.
- Confined space oxygen range
- Acceptable atmospheric oxygen for entry is 19.5 to 23.5 percent. Below or above this range, ventilate and retest before entry with a calibrated gas meter.
- Lockout tagout purpose
- Isolates and locks energy sources such as electricity, pressure, or steam before servicing equipment. Verify zero energy by attempting a start and checking gauges before work begins.
- Fire extinguisher class C
- For fires involving energized electrical equipment. Use a non-conductive agent such as carbon dioxide or dry chemical. Never apply water while the equipment is energized.
- Drawing scale 1:100
- One unit on the drawing represents 100 units on site. A 30 mm line on paper equals 3,000 mm or 3 m in the building. Check the scale bar before measuring.
- Floor drain symbol
- A circle with a cross inside represents a floor drain on plumbing plans. A circle with a diagonal line is a cleanout, and a square with a circle is a vent terminal.
- Drawing versus specification
- Drawings show geometry, location, and routing. Specifications define material grades, jointing, testing, and fixture types. The specification governs quality unless a later revision states otherwise.
- Riser diagram purpose
- A schematic elevation showing vertical pipe runs, stack connections, vent routing, and fixture levels. It is not to scale and is read with the floor plan for layout.
- Fitting take-off
- The distance from the fitting center to its face, subtracted from center-to-center pipe length to obtain the actual cut length. Values differ by fitting type and size.
- 45 degree offset formula
- Offset equals travel times 0.707; travel equals offset times 1.414. For a 22.5 degree offset, travel equals offset times 2.613. Use for pipe routing around obstructions.
- Slope fall formula
- Fall equals run length times gradient. A 12 m run at 1:50 falls 0.24 m. Express gradient as a ratio such as 1:50 or as a percentage such as 2 percent.
- 3-4-5 square check
- A triangle with sides in ratio 3-4-5 has a right angle between the short sides. Use it to set out square pipe runs and confirm layout before cutting or drilling.
- Copper tube types K L M
- Type K is thickest for underground and heavy duty; L is standard for supply; M is thin wall for above ground; DWV is thinnest for drainage. Match type to service.
- Schedule 40 versus 80 PVC
- Schedule 80 has thicker walls and a higher pressure rating than schedule 40 at the same nominal size. Use schedule 80 for high-pressure or industrial service.
- Wye branch fitting
- A Y-shaped drainage fitting that joins a branch at a shallow angle to promote smooth flow and reduce clogging. Preferred over a tee on horizontal drainage runs.
- PTFE tape application
- Wrap tape clockwise around male threads, two to three turns, leaving the first thread bare. Apply tape only to male threads; never to female threads or to flare connections.
- NPT thread taper
- Standard pipe threads are tapered at 1:16, so the joint tightens as it engages. A properly cut thread engages a fitting by hand for two to three turns.
- Solvent weld cure time
- After joining PVC or CPVC, allow the joint to cure before pressure testing. Cure time increases with pipe diameter and decreases with temperature; follow the cement manufacturer's table.
- Soldering versus brazing
- Soldering uses filler melting below 450 degrees Celsius; brazing uses filler above that. Potable water joints require lead-free solder and approved flux.
- Copper bend radius rule
- Minimum bend radius is typically three to five times the pipe diameter. Use a spring or lever bender and annealed copper for tight bends to avoid flattening or kinking.
- Pressure reducing valve setting
- Installs downstream of the meter when supply pressure exceeds about 550 kPa or 80 psi. Typical setting is 350 to 550 kPa to protect fixtures and reduce noise.
- Fixture unit method
- Assigns fixture units to each fixture, sums them, and converts to probable demand using a code table. The demand then sizes the pipe to limit velocity and friction loss.
- Water hammer arrestor
- A device with a trapped air or piston chamber installed near quick-closing valves to absorb pressure surges. It prevents banging and protects joints from fatigue.
- Hydrostatic test pressure
- Test water supply piping at 1.5 times working pressure or per code, commonly 690 kPa or 100 psi, held for at least one hour with no pressure drop.
- DWV slope for 100 mm pipe
- A 100 mm or 4 inch drain is typically laid at 1:100 or 1 percent. Smaller pipe such as 50 mm uses 1:50 or 2 percent. Confirm the value in the applicable code.
- Trap seal depth
- The water seal in a fixture trap is normally 50 to 100 mm or 2 to 4 inches. A shallower seal evaporates easily; a deeper seal is not permitted because it traps air.
- Stack vent height
- The vent extending above the roof must rise at least 150 mm or 6 inches above the roof surface, or above the depth of snow where snow loads apply.
- Cleanout placement
- Required at the base of each stack, at changes of direction greater than 45 degrees, and at intervals of about 15 m or 50 ft on horizontal runs. It must remain accessible.
- Water closet rough-in
- The distance from the finished wall to the centerline of the closet flange, commonly 300 mm or 12 inches. Verify against the fixture manufacturer's rough-in sheet before setting.
- Flush valve vacuum breaker
- Must be installed at least 150 mm or 6 inches above the fixture rim to prevent backflow. Test by shutting off the valve and confirming the breaker opens and drains.
- T&P relief valve discharge
- The temperature and pressure relief valve on a water heater must discharge to a safe point through a full-size pipe, with no valve or trap, and terminate visibly.
- Gurgling drain cause
- Usually a blocked or undersized vent, not a drain blockage. Air cannot enter behind the flowing water, so the trap seal is siphoned. Inspect the vent before rodding.