RAC Servicing (DomRAC) NC II study materials
RAC Servicing (DomRAC) NC II study resources

RAC Servicing (DomRAC) NC II study plan

RAC Servicing (DomRAC) NC II · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Core: Servicing and Maintenance of Domestic Refrigeration and Air Conditioning Units & Core: Refrigerant Handling, Recovery, and Environmental Safety

  • Explain the refrigeration cycle (compression, condensation, expansion, evaporation) and identify each component on a split-type and a window-type unit

  • List the safety and environmental rules for handling R-32, R-410A, and R-290 refrigerants, including flammability, pressure, and venting prohibitions

  • Demonstrate the correct use of a manifold gauge set, vacuum pump, and refrigerant recovery machine in a supervised practice session

  • Describe the preventive maintenance schedule for evaporator coils, condenser coils, filters, and drain pans, and state the symptom each neglected task causes

Your checkpoint

A one-page service checklist for a split-type AC unit covering the full maintenance cycle plus a labeled diagram of the refrigeration cycle with component functions

Week 2

Core: Servicing and Maintenance of Domestic Refrigeration and Air Conditioning Units & Core: Troubleshooting and Repair of Domestic Refrigeration and Air Conditioning Systems

  • Diagnose common cooling faults (low refrigerant charge, restricted capillary tube, dirty condenser, faulty capacitor) from pressure, temperature, and current readings

  • Measure superheat and subcooling on a running unit and state whether each reading indicates undercharge, overcharge, or restriction

  • Interpret electrical readings with a multimeter and clamp meter to isolate compressor, fan motor, and capacitor failures

  • Sequence the steps for recovering refrigerant before opening a sealed system, including recovery cylinder handling and weight recording

Your checkpoint

A fault-diagnosis table matching at least eight symptoms to probable causes, confirming measurements, and corrective actions

Week 3

Core: Installation and Commissioning of Domestic Refrigeration and Air Conditioning Units & Core: Servicing and Maintenance of Domestic Refrigeration and Air Conditioning Units

  • Plan the installation of a split-type AC unit: site survey, load estimate, pipe routing, drain slope, and electrical requirements

  • Perform brazing with nitrogen purge and pressure-test a newly assembled line set to the specified test pressure

  • Evacuate a system to the target micron level and record the standing vacuum decay result

  • Commission a unit by charging to manufacturer specifications and verifying supply-air temperature differential and operating currents

Your checkpoint

A complete installation and commissioning worksheet for a 1.0-HP split-type unit with test pressures, vacuum readings, charge weight, and final performance readings

Week 4

Core: Troubleshooting and Repair of Domestic Refrigeration and Air Conditioning Systems & Common Competencies (tools and equipment, measurement, materials handling, documentation)

  • Trace an electrical schematic of a domestic refrigerator and identify the defrost timer, thermostat, overload protector, and PTC relay in the circuit

  • Use a multimeter to test continuity, resistance, and insulation on a compressor winding set, and decide whether the compressor is serviceable

  • Select and inspect the correct tools for a repair job, checking calibration status and safe condition before use

  • Repair a simulated no-cool fault on a refrigerator by isolating the failed component and documenting the replacement

Your checkpoint

A written repair report for one refrigerator fault including the schematic trace, measured values, replaced part, and post-repair verification readings

Week 5

Core: Troubleshooting and Repair of Domestic Refrigeration and Air Conditioning Systems & Core: Refrigerant Handling, Recovery, and Environmental Safety

  • Diagnose and correct a refrigerant leak using an electronic leak detector and soap-bubble confirmation, then repair and re-test the joint

  • Recover, recycle, and recharge refrigerant following the correct cylinder, scale, and hose-purge procedure while recording weights

  • Handle a simulated refrigerant release scenario: isolate the area, ventilate, use PPE, and follow reporting steps

  • Explain the legal and environmental obligations for refrigerant recovery, record keeping, and non-venting under current regulations

Your checkpoint

A refrigerant handling log for one complete recovery and recharge job showing starting weight, recovered weight, charged weight, and leak-test result

Week 6

Basic Competencies (workplace communication, teamwork, safety, quality standards) & Common Competencies (tools and equipment, measurement, materials handling, documentation)

  • Write a clear customer service report describing a fault, the repair performed, and the parts used, in plain language

  • Deliver a short verbal handover to a teammate using standard technical terms and confirm understanding by asking them to repeat the key points

  • Apply 5S and workplace quality standards to a simulated work area, and identify unsafe conditions against a hazard checklist

  • Complete an equipment maintenance and calibration record for the meters and gauges used in earlier weeks

Your checkpoint

A customer-facing service report plus a completed hazard and 5S audit checklist for a simulated work area

Week 7

Core: Installation and Commissioning of Domestic Refrigeration and Air Conditioning Units & Core: Troubleshooting and Repair of Domestic Refrigeration and Air Conditioning Systems

  • Install and commission a window-type or floor-mounted unit end to end within a set time limit, following the full procedure without a reference sheet

  • Troubleshoot three timed fault scenarios covering electrical, refrigerant, and airflow faults, and state the cause before confirming with a measurement

  • Verify final performance against manufacturer specifications and explain any deviation

  • Complete documentation for each job, including test results, parts used, and customer sign-off

Your checkpoint

Three timed fault scenarios resolved with a written cause-and-fix note for each, plus one full installation checklist completed under time pressure

Week 8

Basic Competencies (workplace communication, teamwork, safety, quality standards) & Core: Servicing and Maintenance of Domestic Refrigeration and Air Conditioning Units & Core: Refrigerant Handling, Recovery, and Environmental Safety

  • Answer practice questions across all six domains and review every missed item until the underlying fact is explained in your own words

  • Recite the safety, refrigerant handling, and environmental rules from memory without notes

  • Run a full mock practical assessment covering maintenance, troubleshooting, and refrigerant recovery within the allotted time

  • Identify your three weakest areas and write a short revision plan for each

Your checkpoint

A mock exam score sheet by domain with a written revision plan for the three weakest areas

Milestones

Week 2: Can identify the cause of at least six of eight common cooling faults from gauge and meter readings alone, without hints

Week 4: Can trace a refrigerator electrical circuit and correctly decide whether a compressor is serviceable based on measured winding values

Week 6: Can complete a refrigerant recovery and recharge with accurate weight records and no venting, and explain the environmental rules unaided

Week 8: Scores at least 80 percent on the mock written exam and completes the mock practical assessment within the time limit with no safety violations