Bilge Pump Loses Suction

PN Sailor Initial Test · Put your knowledge to work in context.

All case studies

Bilge Pump Loses Suction

During a flooding drill, a portable centrifugal bilge pump is rigged to dewater a forward compartment. The pump is rated at 400 liters per minute at 2.5 bar. The suction hose is 6 meters long with a 3-meter vertical lift; the discharge hose is 15 meters long. After four minutes, flow drops to almost nothing. The pump casing is hot, the suction hose is partly collapsed, the discharge gauge reads 0.3 bar, and the vacuum gauge at the suction reads minus 0.7 bar. The bilge suction valve is open, the sea suction valve is closed, and the discharge valve is open. The strainer at the hose end is partly blocked by rags. The priming cap is tight and pump speed is normal. A sailor proposes opening the discharge bypass to “relieve pressure.” Another proposes adding a second suction hose in parallel. You must choose the next action and explain it.

1. Diagnose the most likely cause of the loss of flow, using at least three specific readings, and explain why the bypass proposal is wrong.

Read the worked answer

The pattern points to a suction restriction, not a discharge overpressure problem.

  • The suction vacuum is minus 0.7 bar, which is a high vacuum for this pump. That indicates the pump is pulling hard against a restriction.
  • The suction hose is partly collapsed, which is physical evidence that the pressure inside the hose is below atmospheric and the hose is being crushed.
  • The discharge pressure is only 0.3 bar, far below the rated 2.5 bar. If the discharge were blocked, discharge pressure would tend to rise, not fall.
  • The casing is hot and flow has dropped, consistent with low flow and cavitation.
  • The strainer is partly blocked by rags, which explains the restriction directly.

Opening the discharge bypass is wrong because there is no high discharge pressure to relieve. A bypass would recirculate what little flow remains, reduce the pump’s useful output further, and may increase heating. The correct response is to stop the pump and clear the suction restriction.

2. State the correct immediate sequence of actions, including valve positions and pump shutdown.

Read the worked answer
  1. Stop the pump and secure its power source. Do not continue running a cavitating pump.
  2. Close the bilge suction valve to isolate the suction line. Keep the discharge valve position controlled; the key is to stop flow before opening the line.
  3. Remove and clean the strainer at the hose end, and inspect the suction hose for delamination, soft spots, or collapse damage. Replace the hose if it is damaged.
  4. Check the priming cap and pump casing; refill and reprime as required by the pump procedure.
  5. Open the bilge suction valve slowly and start the pump. Watch the vacuum gauge, discharge pressure, and hose condition.
  6. If vacuum remains abnormally high or the hose collapses again, stop and investigate further rather than adding hoses or bypassing.

The sequence matters: cleaning the strainer while the pump is running or the valve is open can admit debris or air, and restarting without repriming can damage the pump.

3. Explain why adding a second suction hose in parallel would not solve the problem and could make it worse.

Read the worked answer

The blockage is at the common source: the strainer is partly blocked by rags. A second hose in parallel does not remove that blockage; it just adds another path to the same restricted flow. The pump would still be starved.

It could make things worse in two ways. First, two hoses may increase the area exposed to low pressure, so both hoses could collapse or admit air at their connections. Second, the added hose creates more joints and potential air leaks, which can worsen cavitation and prime loss. The correct fix is to restore the existing suction path-clean the strainer, inspect the hose, reprime, and verify normal vacuum and discharge pressure-before considering any change to the rig.