PSAP study materials
PSAP study resources

PSAP flashcards

PSAP · Build recall with a focused review session.

33 cards. Read the term and the definition here. The deck at the top of this page is optional.

Access control decision elements
Identification is the claimed identity, authentication is the proof, authorization is the permission granted, and accountability is the recorded audit trail of the decision and action.
Annualized loss expectancy
ALE equals single loss expectancy multiplied by annualized rate of occurrence. It converts qualitative risk into a monetary figure used to justify a control's cost.
Defense in depth
Layering deterrence, delay, detection, assessment, and response so that failure of one barrier does not defeat the whole system. Each layer covers another's weakness.
Least privilege
Granting each credential holder only the access needed for their role, reviewed on a defined cycle. It limits insider risk and the blast radius of a compromised credential.
Role-based access control
Permissions are grouped into roles tied to job functions, and users are assigned roles rather than individual door rights. Changes follow role changes, simplifying review and revocation.
Intelligent controller
A door-level panel that stores the local access database and schedules and makes grant or deny decisions without the host. It continues operating during network outages.
Request-to-exit device
A sensor or switch (push button, PIR, or integrated REX) that signals the controller to release the lock for egress. It prevents a valid exit from generating a forced-door alarm.
Door position switch
A reed or Hall-effect contact that reports whether the door is open or closed. The controller uses it to detect held doors and forced doors and to supervise the opening.
OSDP protocol
A bidirectional serial protocol between reader and controller that supports encrypted secure channel, tamper reporting, and reader configuration. It replaces one-way Wiegand for higher assurance.
End-of-line resistor
A resistor placed at the far end of a supervised circuit so the panel can distinguish normal, alarm, open, and short conditions. It detects cut or shorted wiring.
Wiegand interface
A one-way clock-and-data reader interface transmitting the credential number in clear, typically 26 to 40 bits. It cannot authenticate the card, so cloning and replay are possible.
High-frequency smart card
A 13.56 MHz credential supporting mutual authentication and encrypted sectors, such as MIFARE DESFire or SEOS-class cards. It resists cloning better than 125 kHz proximity cards.
Crossover error rate
The point where a biometric system's false accept rate equals its false reject rate. A lower crossover error rate indicates a more accurate matcher at the chosen threshold.
Anti-passback
A rule preventing a credential from entering twice without an intervening exit. It may be hard (deny), soft (allow with log), or time-based (reset after an interval).
Multi-factor authentication
Combining at least two different factor types: something you know, something you have, or something you are. Two credentials of the same type do not qualify.
Fail-safe lock
A lock that unlocks when power is lost, such as a maglock or electric strike on an egress path. Life-safety egress normally requires fail-safe release on alarm or outage.
Fail-secure lock
A lock that remains locked when power is lost, such as some electric bolt locks. It protects the asset during outage but must not be used where free egress is required.
Maglock holding force
The electromagnetic holding strength rated in pounds, commonly 600 to 1,200. It requires a request-to-exit device and a code-compliant means of release on the egress side.
Electric strike
A strike plate replacement that releases the latch on a signal. It requires the door to be latched and is unsuitable where the frame cannot be modified or positive latching must be maintained.
Held-door alarm
An alarm generated when a door remains open beyond a programmable time after a valid grant. It detects propped doors and tailgating and is reported to monitoring.
Fire alarm release interface
A supervised relay from the fire alarm system that releases access-controlled egress doors on alarm. It is part of the fire system and is tested during commissioning.
Door schedule
A design document listing each opening with its credential group, schedule, hardware type, and monitoring requirement. It becomes the basis for the bill of materials.
Commissioning test
Per-door verification of grant, deny, request-to-exit, door position, forced and held alarms, fire release, and power-fail behavior, recorded and signed off before handover.
As-built documentation
Final records including door schedules, wiring diagrams, IP addressing, controller configuration exports, and credential group definitions. They are essential for maintenance and audit.
Network segmentation for PACS
Placing controllers and readers on a dedicated VLAN with access control lists limiting traffic to the host server and management systems, with no direct internet exposure.
OSDP Secure Channel
An encrypted, authenticated mode of the OSDP reader-to-controller protocol. It prevents eavesdropping and replay that are possible with clear-text Wiegand transmission.
Default credential change
Replacing vendor default passwords and accounts on controllers and hosts before commissioning. Unchanged defaults are a leading cause of PACS compromise.
Log correlation with NTP
Synchronizing PACS, video, and network devices to a common time source so authentication events and door alarms align with recorded video during investigation.
Forced-door alarm
An alarm generated when a door opens without a valid grant or request-to-exit. It indicates intrusion or tailgating and triggers a defined monitoring response.
Credential lifecycle
Issuance, activation, suspension, reissue on loss, and termination on separation. Terminated credentials are removed from controller databases, not only from the host.
Access review
Periodic reconciliation of the credential database against the authoritative HR roster. Orphaned and duplicate accounts are removed and the review is documented for audit.
NFPA 101 egress rule
Doors must be openable from the egress side without a key or special knowledge. Access-controlled egress doors must release on fire alarm or power loss per the code edition.
PIV credential standard
FIPS 201, issued under HSPD-12, defines the federal Personal Identity Verification credential. It is widely referenced for high-assurance identity proofing and credentialing.