RDA study materials
RDA study resources

RDA (Other exams) cheat sheet

RDA · Keep the key ideas within reach.

Quick reference

Infection Control and Safety Practices

  • Standard precautions are applied to every patient regardless of known or presumed infectious status; diagnosis never determines the level of protection used.

  • Spaulding classification: critical items (enter sterile tissue or vasculature) require sterilization; semicritical items (contact mucous membranes) require high-level disinfection at minimum; noncritical items (intact skin contact only) require low-level disinfection.

  • Gravity steam autoclave cycle: 121 C (250 F) at 15 psi for 15-30 minutes; flash cycle: 132 C (270 F) at approximately 27-30 psi for 3-4 minutes.

  • Biological monitoring is run at least weekly: Geobacillus stearothermophilus spores for steam and chemical vapor sterilizers; Bacillus atrophaeus spores for dry heat and ethylene oxide.

  • Each pack carries an internal chemical indicator plus an external process indicator, and every load is logged with cycle type, temperature, pressure, time, and operator.

  • Soap and water is required when hands are visibly soiled and after contact with spore-formers such as Clostridioides difficile or norovirus; alcohol-based rub is used in all other routine situations.

  • PPE doffing order is gloves first, then eyewear or face shield, then gown, then mask or respirator last, followed immediately by hand hygiene.

  • Dental unit water used for irrigation must contain no more than 500 CFU/mL of heterotrophic bacteria; lines are flushed at the start of the day and between patients.

  • Post-exposure management: wash the site, report immediately, and begin HIV post-exposure prophylaxis as soon as possible, ideally within 2 hours of exposure.

Quick reference

Radiation Health and Safety Practices

  • ALARA: all exposures are kept as low as reasonably achievable, using the shortest acceptable exposure time, fastest receptor, and tightest collimation.

  • Occupational effective dose limit is 50 mSv (5 rem) per year; cumulative lifetime allowance is 10 mSv multiplied by age in years; the public limit is 1 mSv per year.

  • Total filtration must be at least 1.5 mm aluminum equivalent for machines operating at or below 70 kVp and at least 2.5 mm Al equivalent above 70 kVp.

  • Rectangular collimation restricts the beam to the receptor outline, cutting the irradiated tissue area by roughly 60 percent and reducing patient dose compared with round collimation.

  • A 16-inch (long) position indicating device lowers skin dose by about 50 percent compared with an 8-inch (short) PID because it reduces beam divergence at the skin surface.

  • F-speed intraoral film requires roughly 60 percent less exposure than D-speed film and about 20 percent less than E-speed film.

  • Direct digital sensors require only about one-fifth to one-tenth of the exposure needed for D-speed film, an 80-90 percent dose reduction.

  • During exposure the operator stands at least 6 feet from the tube head at a 90- to 135-degree angle to the primary beam, behind a barrier when one is available.

  • The central ray must be perpendicular to the receptor and the PID aligned within 20 degrees of the receptor plane; a 0.25 mm lead-equivalent apron is the minimum patient shield.

Quick reference

Chairside Assisting and Clinical Procedures

  • Four-handed clock positions for a right-handed clinician: dentist 8-10 o'clock, assistant 2-4 o'clock, and the instrument transfer zone over the patient's chest at 4-7 o'clock.

  • Instruments are transferred single-handed and handle-first in a pen grasp, with the assistant holding the instrument parallel to and slightly above the clinician's fingers.

  • A high-volume evacuator placed near the working area removes roughly 90 percent or more of oral fluids and aerosols; a saliva ejector removes only small pooled volumes.

  • Rubber dam stock is 5 x 5 inches for anterior teeth and 6 x 6 inches for posterior teeth; a floss ligature on the clamp prevents aspiration if the clamp is dropped.

  • Paralleling technique places the receptor parallel to the tooth long axis with the central ray perpendicular; bisecting technique aims the ray perpendicular to the plane bisecting the angle between tooth and receptor.

  • A standard local anesthetic cartridge holds 1.8 mL in the United States; 2 percent lidocaine with 1:100,000 epinephrine delivers 36 mg lidocaine and 0.018 mg epinephrine per cartridge.

  • Aspiration for several seconds precedes deposition; a positive blood draw indicates intravascular placement and requires needle repositioning before continuing.

  • A matrix band restores proximal contour while a wedge separates teeth, adapts the band cervically, and prevents gingival excess of restorative material.

  • Retraction cord is packed into the sulcus before impressioning to displace tissue, control crevicular fluid, and expose the finish line; it is removed before the final impression.

Quick reference

Dental Materials and Instrument Management

  • Alginate is an irreversible hydrocolloid that is dimensionally unstable; the impression is poured within about 12 minutes because the gel both imbibes and loses water.

  • Vinyl polysiloxane and polyether impressions are far more stable than alginate; polyether is hydrophilic and rigid but has a bitter taste and short working time.

  • Typical water-to-powder ratios: dental plaster 0.45-0.50, dental stone 0.28-0.30, high-strength die stone 0.22-0.24.

  • For gypsum products, raising the water-to-powder ratio increases setting time and setting expansion while reducing compressive strength and density; potassium sulfate accelerates set and borax retards it.

  • Zinc phosphate cement is mixed on a cool, dry slab by adding powder to liquid in small increments over 60-90 seconds; the mix is used while it still has a glossy surface.

  • Light-cured composite is placed in increments no thicker than 2 mm because curing-light penetration is limited; darker and more opaque shades cure shallower.

  • Curing lights emit blue light at roughly 400-500 nm, with camphorquinone-based composites activated near 470 nm.

  • Etching uses 37 percent phosphoric acid for about 15 seconds on enamel and 10-15 seconds on dentin, followed by thorough rinsing and controlled drying.

  • Glass ionomer bonds chemically to enamel and dentin and releases fluoride over time, but it is moisture sensitive and needs a protective coating during initial set.

Quick reference

Patient Records, Ethics, and Administrative Duties

  • HIPAA requires that protected health information be used or disclosed only under treatment, payment, or operations, limited to the minimum necessary for the purpose.

  • Records are kept for the period required by state law and at least until the malpractice statute of limitations expires, commonly 7 years after the last treatment; minors' records are held until majority plus the statutory period.

  • Informed consent requires disclosure of the diagnosis, the nature and purpose of the proposed treatment, material risks and benefits, alternatives including no treatment, and the consequences of declining.

  • Chart errors are corrected with a single line through the entry plus the correction, initials, and date; erasures, correction fluid, and backdating are never acceptable.

  • SOAP notes organize documentation into subjective patient reports, objective clinical findings, assessment or diagnosis, and the plan of care.

  • The five ADA Code of Ethics principles are patient autonomy, nonmaleficence, beneficence, justice, and veracity.

  • Confidentiality may be breached without consent when legally required, such as reportable communicable diseases, suspected child or elder abuse, and court-ordered disclosures.

  • HIPAA breach notification to affected individuals is made without unreasonable delay and no later than 60 days after discovery of the breach.

  • Minors generally cannot consent to treatment; a parent or legal guardian signs unless state law grants emancipated minor or mature minor status.