RDA (Other exams) flashcards
RDA · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Spore test organisms
- Biological monitoring of steam and chemical vapor sterilizers uses Geobacillus stearothermophilus spores, while dry heat and ethylene oxide sterilizers are monitored with Bacillus atrophaeus spores.
- Alcohol-based hand rub use
- Alcohol-based hand rub is appropriate when hands are not visibly soiled; soap and water is required when hands are soiled and after exposure to spore-forming organisms such as Clostridioides difficile.
- Semicritical item processing
- Semicritical items contact mucous membranes or nonintact skin and require high-level disinfection at minimum; examples include mouth mirrors and reusable impression trays.
- Dental unit waterline limit
- Water used for dental irrigation must contain no more than 500 colony-forming units per milliliter of heterotrophic bacteria, the standard recommended by the CDC for dental unit waterlines.
- PPE removal order
- Remove gloves first, then eyewear or face shield, then gown, and finally the mask or respirator, because the front of the mask is considered contaminated throughout the procedure.
- Sharps container fill level
- Sharps containers are replaced when about three-quarters full and are never overfilled, because overfilling increases the risk of needlestick injury during closure and disposal.
- Post-exposure HIV prophylaxis timing
- After a percutaneous exposure to HIV, wash the site with soap and water, report immediately, and begin post-exposure prophylaxis as soon as possible, ideally within two hours.
- Occupational radiation dose limit
- The annual occupational effective dose limit is 50 mSv, or 5 rem, per year; the cumulative lifetime allowance is 10 mSv multiplied by the worker's age in years.
- Inverse square law
- Radiation intensity is inversely proportional to the square of the distance from the source, so doubling the distance from the tube head reduces exposure to one quarter.
- Rectangular collimation benefit
- Rectangular collimation restricts the beam to the shape of the receptor, reducing the irradiated tissue area by roughly 60 percent and lowering patient dose compared with round collimation.
- F-speed film dose
- F-speed intraoral film requires about 60 percent less exposure than D-speed film and roughly 20 percent less than E-speed film, making it the fastest conventional film.
- Half-value layer meaning
- The half-value layer is the thickness of a specified material that reduces the intensity of the x-ray beam by half, and it measures beam quality and filtration adequacy.
- Operator position during exposure
- During exposure the operator stands at least 6 feet from the tube head at a 90- to 135-degree angle to the primary beam, behind a protective barrier when one exists.
- Instrument transfer zone
- In four-handed dentistry the transfer zone lies over the patient's chest between 4 and 7 o'clock, allowing instruments to be exchanged outside the patient's field of view.
- High-volume evacuator efficiency
- A high-volume evacuator tip placed near the working area removes roughly 90 percent or more of oral fluids and aerosols, whereas a saliva ejector removes only small pooled amounts.
- Rubber dam clamp purpose
- A rubber dam clamp secures the punched dam on the anchor tooth; a floss ligature tied to the clamp prevents aspiration if the clamp slips during placement or removal.
- Bisecting angle principle
- The bisecting angle technique directs the central ray perpendicular to the plane that bisects the angle between the tooth long axis and the receptor, minimizing distortion.
- Gingival retraction cord purpose
- Retraction cord is packed into the gingival sulcus before impressioning to displace tissue temporarily, control sulcular fluid, and expose the finish line for an accurate impression.
- Standard anesthetic cartridge volume
- A standard dental anesthetic cartridge holds 1.8 mL in the United States; a 2 percent solution contains 20 mg per mL, so one cartridge delivers 36 mg of lidocaine.
- Aspiration before injection
- The clinician aspirates for several seconds before depositing solution; a positive blood return indicates intravascular needle placement and requires repositioning before the injection continues.
- Alginate impression pouring window
- Alginate is an irreversible hydrocolloid that is dimensionally unstable, so impressions should be poured within about 12 minutes before imbibition and syneresis distort the surface.
- Composite curing depth
- Light-cured composite is placed in increments no thicker than 2 mm because curing light penetration is limited; darker and more opaque shades reduce the depth of cure further.
- Gypsum water-to-powder effect
- Increasing the water-to-powder ratio of dental gypsum increases setting time and setting expansion while decreasing the compressive strength and density of the final cast.
- Zinc phosphate cement mixing
- Zinc phosphate cement is mixed on a cool, dry slab by incorporating powder into liquid in small increments over 60 to 90 seconds, and used before it loses gloss.
- Glass ionomer fluoride release
- Glass ionomer cement bonds chemically to enamel and dentin and releases fluoride over time, but it is moisture sensitive and needs a protective coating during initial setting.
- Curing light wavelength
- Dental curing lights emit blue light in the 400 to 500 nanometer range, with camphorquinone-based composites activated most efficiently near 470 nanometers.
- Sharpening cutting instruments
- Hand cutting instruments are sharpened on a flat stone at the original bevel angle with a stable finger rest; dull scalers crush and burnish calculus instead of removing it cleanly.
- Record retention period
- Patient records are kept for the period set by state law and at least until the malpractice statute of limitations expires, often seven years past the last treatment date.
- Informed consent elements
- Valid informed consent discloses the diagnosis, proposed treatment, material risks and benefits, alternatives including no treatment, and the consequences of declining care.
- SOAP charting format
- SOAP charting organizes progress notes into subjective findings reported by the patient, objective clinical observations, assessment or diagnosis, and the plan for treatment.
- Correcting chart errors
- A charting error is corrected by drawing a single line through the entry, writing the correction, and initialing and dating it; erasures and correction fluid are never acceptable.
- Mandatory reporting exceptions
- Confidentiality may be breached without patient consent when required by law, including reportable communicable diseases, suspected child or elder abuse, and court-ordered disclosures.