Quick reference

Cardiac Anatomy and Physiology

  • The left ventricle is divided into 17 segments: six basal, six mid, four apical, and one apical cap; the apical segments and cap are assigned to the LAD territory.

  • Ejection fraction equals end-diastolic volume minus end-systolic volume divided by end-diastolic volume; a normal value is approximately 55-70%.

  • Cardiac output equals stroke volume times heart rate; stroke volume can be calculated as LVOT area multiplied by LVOT velocity-time integral.

  • LVOT area is calculated as pi times the square of half the LVOT diameter; the diameter is measured in mid-systole in the parasternal long-axis view.

  • Grade 1 diastolic dysfunction shows E/A below 0.8; grade 2 shows E/A 0.8-1.5 with elevated filling pressures; grade 3 shows E/A above 2 with restrictive filling.

  • Septal e' below 7 cm/s and lateral e' below 10 cm/s suggest impaired myocardial relaxation; E/e' above 14 suggests elevated left atrial pressure.

  • Right ventricular systolic pressure equals 4 times the square of peak tricuspid regurgitation velocity plus right atrial pressure estimated from IVC size and collapse.

  • Normal valve areas are approximately 3-4 cm² for the aortic valve, 4-6 cm² for the mitral valve, 7 cm² for the tricuspid valve, and 3 cm² for the pulmonary valve.

  • The normal pericardial space contains less than 50 mL of fluid; an echo-free space between the pericardium and myocardium indicates a pericardial effusion.

Quick reference

Ultrasound Physics and Instrumentation

  • Frequency equals propagation velocity divided by wavelength; average soft-tissue propagation velocity is approximately 1540 m/s.

  • Attenuation in soft tissue is approximately 0.5 dB per centimeter per megahertz one-way; higher frequencies improve resolution but reduce penetration.

  • Axial resolution equals spatial pulse length divided by two; it improves with higher frequency and fewer cycles per pulse and is typically 0.5-1 mm.

  • Lateral resolution is worse than axial resolution and depends on beam width, transducer frequency, and depth; it improves with focusing.

  • The Nyquist limit equals pulse repetition frequency divided by two; Doppler shifts above this limit alias and wrap to the opposite direction.

  • Aliasing can be reduced by increasing pulse repetition frequency, lowering transducer frequency, or adjusting the color scale and baseline.

  • The Doppler equation is shift equals 2 times transducer frequency times velocity times cosine of the angle, divided by propagation velocity.

  • Pulsed-wave Doppler provides range resolution but aliases; continuous-wave Doppler records high velocities without aliasing but lacks range resolution.

  • Frame rate equals pulse repetition frequency divided by lines per frame; color Doppler, wider sectors, and greater depth reduce frame rate.

Quick reference

Two-Dimensional, M-Mode, and Doppler Acquisition Technique

  • The parasternal long-axis view displays the right ventricle anteriorly, the left ventricle, aortic root, and left atrium; LVOT diameter is measured in mid-systole.

  • The apical four-chamber view places the LV apex at the top of the sector and is used for Simpson's biplane ejection fraction and mitral inflow Doppler.

  • Simpson's biplane method traces end-diastolic and end-systolic endocardial borders in apical four- and two-chamber views to calculate LV volumes.

  • M-mode uses a single cursor line with high temporal resolution; the cursor should be perpendicular to the structure, such as the aortic valve or mitral leaflets.

  • Pulsed-wave Doppler uses a sample volume for low-velocity flow with range resolution; it is used for LVOT, mitral inflow, and pulmonary vein velocities.

  • Continuous-wave Doppler is used for high-velocity jets such as aortic stenosis because it does not alias, but it cannot localize flow along the beam.

  • Color Doppler scale should be set above the expected velocity to avoid aliasing; variance maps display turbulent flow.

  • Tissue Doppler imaging samples myocardial motion at the septal and lateral mitral annulus to measure e' and a' velocities.

  • Doppler angle correction is applied to vascular flow but not to cardiac valve jets; valve velocities are most accurate when the beam is within 20 degrees of flow.

Quick reference

Valvular Heart Disease and Hemodynamics

  • The continuity equation calculates aortic valve area as LVOT area times LVOT VTI divided by aortic valve VTI.

  • Severe aortic stenosis is defined by peak velocity at least 4 m/s, mean gradient at least 40 mmHg, or valve area below 1.0 cm².

  • The dimensionless index is LVOT VTI divided by aortic valve VTI; a value below 0.25 indicates severe aortic stenosis.

  • Mitral valve area by pressure half-time equals 220 divided by pressure half-time in milliseconds; a half-time above 220 ms suggests severe mitral stenosis.

  • Severe mitral regurgitation is suggested by a vena contracta of at least 0.7 cm or a PISA-derived effective regurgitant orifice area of at least 0.4 cm².

  • Aortic regurgitation pressure half-time below 200 ms suggests severe regurgitation; holodiastolic flow reversal in the descending aorta supports severity.

  • Tricuspid regurgitation velocity above 2.8 m/s suggests elevated right ventricular systolic pressure; a value above 3.4 m/s suggests severe pulmonary hypertension.

  • Normal prosthetic mean gradients are generally below 20 mmHg for aortic and below 5 mmHg for mitral valves; higher gradients suggest obstruction or patient-prosthesis mismatch.

  • Pulmonary stenosis with a peak velocity above 4 m/s or a mean gradient above 40 mmHg is considered severe.

Quick reference

Cardiomyopathy, Pericardial Disease, and Congenital/Acquired Pathology

  • Hypertrophic cardiomyopathy shows asymmetric septal hypertrophy of at least 15 mm, systolic anterior motion of the mitral leaflet, and dynamic LVOT obstruction with gradient at least 30 mmHg.

  • Cardiac amyloidosis shows thickened ventricular walls, a granular sparkling texture, apical sparing of longitudinal strain, and low ECG voltage relative to wall thickness.

  • Restrictive cardiomyopathy shows biatrial enlargement, normal or reduced LV cavity size, and grade 3 diastolic dysfunction with elevated filling pressures.

  • Cardiac tamponade shows a pericardial effusion with right atrial systolic collapse, right ventricular diastolic collapse, IVC plethora, and respiratory variation in inflow velocities.

  • Constrictive pericarditis shows pericardial thickening, septal bounce, annulus paradoxus, and medial e' greater than lateral e' on tissue Doppler.

  • Dilated cardiomyopathy shows LV dilation and reduced ejection fraction, often with functional mitral regurgitation; LV thrombus may require anticoagulation.

  • An atrial septal defect causes right heart volume overload, color flow across the interatrial septum, and increased pulmonary-to-systemic flow ratio.

  • A Stanford type A aortic dissection shows an intimal flap in the ascending aorta and is a surgical emergency; color Doppler may distinguish true and false lumens.