RDMS Abdomen study materials
RDMS Abdomen study resources

RDMS Abdomen cheat sheet

RDMS Abdomen · Keep the key ideas within reach.

Quick reference

Basic Abdominal Anatomy

  • The liver is divided into eight Couinaud segments, each with its own portal venous, hepatic arterial, and biliary branch; hepatic veins run between segments.

  • The portal triad contains the main portal vein, proper hepatic artery, and common bile duct, all within the hepatoduodenal ligament; the portal vein is the largest.

  • Normal common bile duct measures up to 6 mm, increasing about 1 mm per decade after age 60, and may reach 10 mm after cholecystectomy.

  • Adult kidney length is 9-12 cm; the right kidney sits lower than the left because of the liver, and normal renal cortex is hypoechoic to liver and spleen.

  • Normal spleen measures up to 13 cm in length, 7 cm in width, and 5 cm in thickness, and is slightly more echogenic than the liver.

  • Pancreas is imaged in the head, neck, body, and tail; the normal pancreatic duct measures 2-3 mm, with the splenic vein and SMA as landmarks.

  • The bowel wall shows five sonographic layers (gut signature), alternating echogenic and hypoechoic, from mucosa to serosa.

  • Surface anatomy: the portal splenic confluence lies anterior to the IVC and is formed by the superior mesenteric and splenic veins.

Quick reference

Perfusion and Function

  • Resistive index: RI = (peak systolic velocity - end-diastolic velocity) / peak systolic velocity; normal renal RI is 0.55-0.70.

  • Normal hepatic artery shows a low-resistance waveform with continuous forward diastolic flow and RI of approximately 0.55-0.70.

  • Portal vein flow is continuous, hepatopetal, and gently undulating with respiration and cardiac pulsation; mean velocity is about 15-30 cm/s.

  • Hepatic veins show a triphasic pulsatile waveform (A, S, D waves) reflecting right heart hemodynamics; loss of pulsatility suggests parenchymal disease.

  • Doppler angle should be 60 degrees or less; the sample gate is placed mid-vessel with the vessel parallel to the angle corrector.

  • Fasting SMA shows a high-resistance waveform with early diastolic reversal that converts to low resistance after a meal.

  • Renal artery acceleration time under 70 ms is normal; a prolonged acceleration time with low amplitude indicates tardus-parvus flow from upstream stenosis.

  • Renal vein flow is continuous and hepatofugal (toward the IVC); pulsatility may increase with right heart failure.

Quick reference

Pathology

  • Simple cyst criteria: anechoic, thin smooth wall, posterior acoustic enhancement, no septations, no internal echoes, and no internal Doppler flow.

  • Hemangioma typically appears as a homogeneous hyperechoic, well-circumscribed mass with no significant internal Doppler flow.

  • Hepatocellular carcinoma arises most often in a cirrhotic liver and shows variable echogenicity with arterial hypervascularity on Doppler.

  • Gallstones are echogenic foci with strong posterior shadowing that move with patient position; sludge is low-level, nonshadowing, and layers dependently.

  • Wall-echo-shadow (WES) complex indicates a gallbladder packed with stones: two echogenic lines separated by a thin hypoechoic bile layer, with clean shadowing.

  • Acute pancreatitis: enlarged, hypoechoic pancreas with peripancreatic fluid and indistinct margins; gallstones are a common cause.

  • Hydronephrosis: mild = anechoic renal pelvis only; moderate = blunted calyces; severe = cortical thinning with bear-paw appearance.

  • Hepatic steatosis: increased liver echogenicity, increased hepatorenal contrast, and poor penetration of deep structures; may be focal or diffuse.

Quick reference

Vascular Abnormalities

  • An infrarenal abdominal aorta is aneurysmal when its outer-to-outer anteroposterior diameter exceeds 3 cm; mural thrombus and residual lumen are measured separately.

  • Renal artery stenosis: peak systolic velocity above 180-200 cm/s, renal-to-aortic velocity ratio greater than 3.5, and post-stenotic tardus-parvus waveform.

  • Portal hypertension signs: portal vein diameter over 13 mm, mean velocity below 15 cm/s, and hepatofugal or biphasic flow, often with splenomegaly and varices.

  • A normal TIPS shows flow velocities of roughly 90-190 cm/s; velocities under 50 cm/s or over 200 cm/s suggest stenosis or dysfunction.

  • Hepatic artery stenosis after transplant: focal PSV greater than 200 cm/s with tardus-parvus downstream; hepatic artery thrombosis shows no flow.

  • Superior mesenteric artery stenosis is suggested by a peak systolic velocity greater than 275 cm/s.

  • Aortic dissection appears as an intimal flap dividing the aorta into a true lumen and a false lumen, each with distinct flow on color Doppler.

  • Renal vein thrombosis: enlarged hypoechoic kidney with absent venous flow and elevated resistive index above 0.80.

Quick reference

Trauma

  • FAST evaluates four windows: perihepatic (Morison's pouch), perisplenic, pelvic (pouch of Douglas), and subxiphoid pericardial.

  • Free intraperitoneal fluid appears anechoic and conforms to dependent recesses; acute hemorrhage may appear echogenic rather than anechoic.

  • The spleen is the most commonly injured solid organ in blunt abdominal trauma, followed by the liver.

  • A subcapsular hematoma is a lenticular or crescentic collection between the capsule and parenchyma that compresses underlying tissue.

  • A liver laceration appears as an ill-defined heterogeneous or hypoechoic disruption of normal parenchyma, often with associated free fluid.

  • FAST has limited sensitivity for retroperitoneal injury, hollow viscus rupture, and pelvic fractures, so a negative study does not exclude injury.

  • Hematoma echogenicity evolves over time: acute collections are echogenic, become complex and hypoechoic, and eventually anechoic.

  • Spectral and color Doppler are not part of the standard FAST protocol; the exam is grayscale, limited, and repeatable at the bedside.

Quick reference

Postoperative Anatomy

  • After cholecystectomy the common bile duct may measure up to 10 mm without obstruction; greater caliber or focal dilatation suggests retained stone or stricture.

  • Surgical clips in the gallbladder fossa cause bright echogenic reflections with clean posterior shadowing and may mimic stones.

  • A TIPS stent appears as two parallel echogenic lines connecting the portal vein to a hepatic vein; patency is confirmed with color and spectral Doppler.

  • A transplanted kidney is usually placed extraperitoneally in the iliac fossa, so the native renal fossa appears empty.

  • Renal transplant dysfunction is suggested by resistive index above 0.80, absent diastolic flow, or perinephric fluid collections.

  • Liver transplant requires evaluation of hepatic artery, portal vein, and IVC anastomoses plus perihilar fluid collections and biliary dilatation.

  • Postoperative collections may be anechoic or complex with septations and debris; ultrasound guides size, location, and drainage planning.

  • Pancreaticoduodenectomy (Whipple) alters upper abdominal anatomy, so the pancreatic remnant, ducts, and surgical bed must be identified before interpretation.

Quick reference

Abdominal Physics

  • Higher transducer frequency improves resolution but decreases penetration; abdominal imaging typically uses a curvilinear 2-5 MHz probe.

  • Axial resolution equals half the spatial pulse length; shorter pulses from higher frequency or fewer cycles per pulse improve it.

  • Posterior acoustic enhancement occurs behind fluid-filled structures such as cysts and the gallbladder because fluid attenuates sound less than soft tissue.

  • Acoustic shadowing occurs behind strongly reflecting or attenuating structures such as bone, stones, and gas, producing a dark band deep to them.

  • Attenuation in soft tissue averages about 0.5 dB/cm/MHz, so deeper structures and higher frequencies return weaker echoes.

  • Aliasing occurs when velocity exceeds the Nyquist limit (half the pulse repetition frequency); correct by raising the scale, adjusting the baseline, or using continuous wave.

  • Mirror-image artifact duplicates a structure across a strong reflector such as the diaphragm, creating a false image deep to the reflector.

  • Edge (refraction) shadowing appears as narrow dark bands at the margins of curved structures such as the gallbladder or fetal head.

Quick reference

Clinical Care and Practice

  • ALARA: keep exposure As Low As Reasonably Achievable by using the lowest output power and shortest scanning time that yields diagnostic information.

  • Mechanical index estimates cavitation risk and is generally kept at or below 1.9 for abdominal scanning; thermal index estimates tissue heating.

  • Patients fast 6-8 hours before abdominal ultrasound to distend the gallbladder and reduce bowel gas; fasting is also used for renal artery Doppler.

  • Endocavitary probes contact mucous membranes and are semicritical devices requiring high-level disinfection after each use; surface probes require low-level disinfection.

  • Documentation includes patient identification, date, transducer orientation, labeled images, and measured values for all reported findings.

  • Critical or unexpected findings, such as a suspected aneurysm or free fluid after trauma, are communicated directly to the referring clinician.

  • Ergonomic practice, including neutral wrist posture, arm support, and alternating scanning hands, reduces sonographer musculoskeletal injury.

  • Standard precautions apply to every patient: hand hygiene, gloves when contacting body fluids, and proper probe and machine cleaning between examinations.