SE Exam flashcards
SE Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Dead load
- Gravity load from permanent construction: structural framing, slabs, walls, finishes, and fixed equipment. ASCE 7 Chapter 3 requires it to be included in every gravity load combination.
- Tributary area
- Area of floor or roof supported by a member, used to convert distributed load into member load. One-way members use span times spacing; two-way panels split along 45-degree lines from the corners.
- Live load reduction equation
- L = L0(0.25 + 15/√(KLL·AT)), where AT is tributary area in square feet and KLL is 4 for columns and 2 for beams and one-way slabs.
- Reduced live load limits
- A reduced live load may not fall below 0.50 L0 for members carrying one floor, or below 0.40 L0 for members carrying two or more floors, per ASCE 7.
- Basic LRFD gravity combination
- 1.2D + 1.6L + 0.5(Lr or S or R) governs when floor live load dominates; a companion case places roof load at full 1.6 factor and floor live at 1.0.
- Snow load on flat roof
- pf = 0.7 Ce Ct Is Pg, where Ce is exposure factor, Ct thermal factor, Is importance factor, and Pg ground snow load; sloped roofs apply an additional Cs factor.
- Impact factor for elevators
- Elevator loads applied to their supports include 100 percent impact; light machinery uses 20 percent and reciprocating machinery 50 percent, per ASCE 7 Section 4.6.
- Composite beam horizontal shear
- V' equals the lesser of AsFy and 0.85f'cAc; the required number of shear studs is V' divided by the nominal single-stud strength Qn.
- Required plastic section modulus
- For a compact braced beam, Zx required equals Mu divided by φFy with φ = 0.90; the available moment φFyZx must equal or exceed the factored moment.
- Compact section limit
- AISC flange and web slenderness ratios must not exceed their plastic limits so the section can reach its plastic moment before local buckling occurs.
- Column effective length KL
- K depends on end restraint: 1.0 pinned-pinned, 0.5 fixed-fixed, 0.7 fixed-pinned, 2.0 fixed-free. Slenderness KL/r is preferably kept at or below 200.
- Flexural buckling stress Fe
- Fe = π²E/(KL/r)². When KL/r is at most 4.71√(E/Fy) the column buckles inelastically and AISC uses Fcr = 0.658^(Fy/Fe)·Fy.
- Two-way slab load split
- Panel corners are divided by 45-degree lines; each supporting beam receives the triangular or trapezoidal area adjacent to it, which sets its distributed load.
- Punching shear at slab-column
- The critical perimeter lies d/2 from the column face; factored shear stress vu = Vu/(bo·d) must not exceed the design punching shear strength per ACI 318.
- IBC deflection limits
- Floor live-load deflection is limited to L/360, roof live-load deflection to L/240, and roof total deflection to L/180; plaster ceilings commonly require L/360 under total load.
- Gravity load path continuity
- Every element must transfer load through a continuous path from the point of application to the foundation, and connections must be designed for the forces in that path.
- Seismic base shear
- V = CsW, where Cs equals SDS/(R/Ie), is capped by SD1/(T·R/Ie) and is not less than 0.044 SDS Ie times the seismic weight.
- Approximate period Ta
- Ta = Ct hn^x, with Ct 0.028 and x 0.8 for steel moment frames, 0.016 and 0.9 for concrete moment frames, and 0.020 and 0.75 for other systems.
- Vertical distribution exponent k
- k equals 1.0 for fundamental periods of 0.5 second or less, 2.0 for 2.5 seconds or more, and is linearly interpolated between those limits.
- Story drift limit
- Allowable drift is 0.020 hsx for Risk Categories I and II, 0.015 for III, and 0.010 for IV; drift is computed as Cd times elastic drift divided by Ie.
- Redundancy factor rho
- The redundancy factor equals 1.3 by default. It may be taken as 1.0 only when the structure satisfies the specific conditions of ASCE 7 Section 12.3.4.2.
- Torsional amplification factor Ax
- Ax = (δmax/δavg)², bounded between 1.0 and 3.0. It applies when torsional irregularity exists and amplifies the accidental torsional moment.
- Velocity pressure qz
- qz = 0.00256 Kz Kzt Kd Ke V² in psf with V in mph; Kz varies with height and exposure, and Kd is 0.85 for buildings.
- Gust effect factor G
- G is taken as 0.85 for rigid structures whose fundamental frequency is at least 1 Hz; flexible or dynamically sensitive structures require the Chapter 26 procedure.
- Internal pressure coefficient GCpi
- GCpi is plus or minus 0.18 for enclosed buildings and plus or minus 0.55 for open and partially enclosed buildings; it is combined with the external pressure coefficient.
- Diaphragm design force Fpx
- Fpx equals the story shear multiplied by wpx/Σwi, bounded between 0.2 SDS Ie wpx and 0.4 SDS Ie wpx for the diaphragm being designed.
- Stability coefficient theta
- θ = PxΔIe/(Vx hsx Cd). When θ is 0.10 or less second-order effects may be ignored; otherwise displacements and forces are amplified by 1/(1−θ).
- Overstrength load combination
- (1.2 + 0.2SDS)D + Ω0E + L + 0.2S and (0.9 − 0.2SDS)D + Ω0E are used where the code requires elements to be designed for overstrength seismic forces.
- Response modification factor R
- R reduces elastic seismic demand to the design level by crediting ductility and overstrength; systems with higher R values carry stricter detailing and configuration requirements.
- Deflection amplification factor Cd
- Cd converts elastic analysis displacements into expected inelastic displacements; it multiplies the elastic drift before comparison with the allowable story drift limit.
- Wind exposure categories
- Exposure B is urban or suburban terrain, C is open terrain with scattered obstructions, and D is flat unobstructed terrain or water; rougher exposure raises Kz.
- Seismic design category
- Categories A through F are assigned from the risk category, SDS, and SD1 values, and they govern the permitted structural systems, analysis procedures, and detailing requirements.