USCG OIM study materials
USCG OIM study resources

USCG OIM cheat sheet

USCG OIM · Keep the key ideas within reach.

Quick reference

Engineering Knowledge and Watchkeeping

  • Diesel engine indicated power: IP = (Pmi × L × A × N × n) / 60 for a two-stroke, where Pmi is mean indicated pressure, L stroke, A bore area, N rpm, n number of cylinders.

  • Brake mean effective pressure relates to brake power by BMEP = (P_b × 60) / (L × A × N × n); mechanical efficiency is BMEP divided by IMEP.

  • Specific fuel consumption (g/kWh) = fuel mass flow (g/h) divided by brake power (kW); a rising trend signals fouling, injector wear, or air restriction.

  • Turbocharger surging on rapid load change is countered by gradual load application and verifying air cooler and scavenge space cleanliness.

  • Main engine lube oil pressure low alarm typically trips the engine; standby pump auto-start is set above the trip setpoint to prevent nuisance shutdowns.

  • Two-stroke crosshead engines use separate cylinder oil (total-loss) and system oil; four-stroke trunk engines share one sump oil for pistons and bearings.

  • Watchkeeping handover must include machinery status, ongoing maintenance, abnormal readings, and standing orders; never hand over during a critical manoeuvre without the chief engineer's approval.

  • Auxiliary boiler low-water trip and flame failure trip must be tested before lighting off; purge the furnace before ignition to clear unburnt fuel.

Quick reference

Electrical, Electronic and Control Engineering

  • Three-phase power P = √3 × V_line × I_line × power factor; reactive power Q = √3 × V × I × sin φ and apparent power S = √3 × V × I.

  • Generator paralleling requires matching voltage, frequency, phase sequence and phase angle; kW load shares via governor droop, kVAr via excitation (voltage droop).

  • Droop setting determines load sharing: a generator with lower droop takes a larger share of kW load for the same frequency deviation.

  • Insulation resistance minimum for a 440 V system is typically 1 MΩ at 500 V DC test; readings below 1 MΩ/kV require investigation before energising.

  • Preferential (interlock) trip: non-essential loads (HVAC, galley, some pumps) shed automatically on generator overload or loss of one generator.

  • Battery capacity: Ah rating at a stated discharge rate; charging voltage for lead-acid float is about 2.25 V/cell, equalising about 2.4 V/cell.

  • A PLC analogue input 4-20 mA loop reads 4 mA at zero and 20 mA at full scale; a live-zero signal allows broken-wire detection (0 mA = fault).

  • Earth fault on an insulated (IT) distribution system is detected by an insulation monitoring device; a single earth fault does not trip but must be located and cleared promptly.

Quick reference

Maintenance and Repair

  • Planned maintenance system intervals are set by running hours, calendar time, or condition (vibration, oil analysis); deferral requires chief engineer authorisation and record.

  • Crankcase oil analysis trends: iron (wear), chromium (rings/liners), sodium (coolant ingress), water, viscosity and TBN (base number depletion).

  • Vibration severity is judged against ISO 10816 zones; a rising trend or zone C/D reading requires investigation before continued running.

  • Hot work permit requires gas-free certificate, fire watch, removal of combustibles, and a check of adjacent spaces; enclosed space entry requires atmosphere test (O2 20.9%, LEL < 1%, H2S/CO within limits) and a standby man.

  • Torque tightening follows the manual's sequence and values; use a calibrated torque wrench and record the calibration date.

  • Lockout/tagout: isolate, prove dead, apply lock and tag, and test the isolation before work; the person working applies their own lock.

  • Pressure testing of piping uses 1.5× design pressure (hydrostatic) unless the code specifies otherwise; relief valves are set and sealed to design pressure.

  • Bearing clearance is measured by bridge gauge or lead wire; compare against the maker's wear limit before deciding to renew.

Quick reference

Marine Engineering Regulatory and Safety

  • MARPOL Annex I: oil discharge overboard is prohibited except through 15 ppm oily water separator with monitoring; the oil record book must record all transfers and disposals.

  • MARPOL Annex VI: sulphur limit 0.50% m/m globally and 0.10% in ECAs; NOx Tier limits apply to engines over 130 kW built after the applicable date; a Bunker Delivery Note must be retained 3 years.

  • An oil record book entry is made without delay; falsification is a criminal offence and the OIM/chief engineer is accountable.

  • Emergency generator must start and take load automatically within 45 seconds of a blackout (SOLAS); emergency fire pump and steering gear have defined independence requirements.

  • STCW watchkeeping: a watch is not left unattended; the engineer on watch must be fit for duty and the relief must be competent and briefed before takeover.

  • Fire triangle: fuel, oxygen, heat; fixed CO2 systems require space evacuation, boundary closing and head count before release.

  • Enclosed space entry requires a permit, atmosphere test, ventilation, standby man at the entrance, and rescue equipment; never enter to rescue without breathing apparatus.

  • Garbage record book (MARPOL Annex V) records discharges and incinerations; plastics must never be discharged to sea.