VCP-NV study materials
VCP-NV study resources

VCP-NV cheat sheet

VCP-NV · Keep the key ideas within reach.

Quick reference

NSX Architecture and Components

  • NSX Manager is the management plane: it hosts the UI and REST API and, since NSX-T 2.5, also the control plane (controller functions are embedded, with no separate controller VMs).

  • A production NSX Manager cluster uses three appliance nodes behind a single VIP; one node is supported only for lab or evaluation use.

  • Host transport nodes are ESXi hosts prepared with NSX kernel modules and a hostswitch (N-VDS or VDS 7.0); they carry the distributed data plane for segments and the distributed firewall.

  • Edge transport nodes are VMs or bare-metal appliances grouped in an edge cluster and provide centralized services: Tier-0 routing, NAT, DHCP, load balancing, VPN, and gateway firewall.

  • An overlay transport zone defines the span of GENEVE-backed segments; a VLAN transport zone carries VLAN-backed segments. A hostswitch can belong to only one overlay transport zone.

  • GENEVE encapsulation uses UDP destination port 6081; the outer headers add roughly 50 bytes for IPv4, so the underlay MTU should be at least 1600 (or jumbo frames).

  • Uplink profiles define teaming policy, active/standby uplinks, transport VLAN, and MTU for hostswitch uplinks; segment profiles bundle switching (MAC, MTU), IP discovery, spoof guard, and QoS settings.

  • Tier-0 is the north-south gateway whose service router runs on the Edge; Tier-1 is a tenant gateway whose downlink router is distributed on every host.

Quick reference

NSX Installation, Configuration, and Upgrade

  • Deploy NSX Manager from the OVA, set management IP, DNS (A and PTR records), and NTP on each node, then form the three-node cluster behind the VIP.

  • Register the compute manager (vCenter) with NSX Manager using vCenter credentials; a given compute manager can be registered to only one NSX Manager cluster.

  • Host preparation installs the NSX VIBs on ESXi and requires a reboot; hostswitch and uplink configuration is then applied by a transport node profile at the vSphere cluster level.

  • Edge node sizes are Small, Medium, Large, and X-Large; sizing is fixed at deployment, and an edge cluster holds multiple Edge nodes for HA and ECMP.

  • IP pools supply tunnel endpoint (TEP) addresses to host and Edge transport nodes; overlay and VLAN traffic can use separate TEP pools.

  • NSX Manager backups are sent to an FTP/SFTP server and can be restored only onto an NSX Manager of the same or a compatible version.

  • Upgrades start with the NSX Manager cluster, which must be fully upgraded before host transport nodes and Edge nodes are upgraded.

  • Every NSX node needs forward and reverse DNS resolution and synchronized time, and the cluster VIP must resolve for API and UI access.

Quick reference

Logical Switching and Routing

  • A segment is a logical switch backed by GENEVE; overlay segments require an overlay transport zone attached to the hostswitch of every participating host.

  • Tier-0 gateway attaches to an edge cluster, owns the north-south service router, and supports BGP, OSPF, static routes, and ECMP toward the physical network.

  • Tier-1 gateway attaches to a Tier-0; its downlink is a distributed router present on each host, keeping east-west routing local to the hypervisor.

  • A Tier-1 service router is instantiated on the Edge only when centralized services (NAT, load balancing, gateway firewall, VPN) are configured on that Tier-1.

  • Tier-1 route advertisement toward Tier-0 covers connected segments and service ports, static routes, NAT IPs, LB VIPs, and IPSec local endpoints.

  • ECMP on a Tier-0 requires multiple Edge nodes in the edge cluster with equal-cost paths to the upstream physical routers.

  • VLAN-backed segments map a segment to a VLAN ID on the transport VLAN and are used to reach physical networks or to bridge overlay and VLAN domains.

  • ARP suppression and IP discovery limit broadcast flooding on overlay segments by answering ARP for known IP-to-MAC bindings.

  • GENEVE adds about 50 bytes of IPv4 overhead; an underlay MTU below 1600 drops large frames unless the MTU is raised on the physical path.

Quick reference

NSX Security

  • The distributed firewall enforces rules at the VM vNIC inside the hypervisor kernel, so east-west traffic is filtered without leaving the host.

  • The gateway firewall is enforced on the Edge service router and controls north-south traffic; L7 features such as URL filtering and TLS inspection require it.

  • DFW rule categories evaluate in a fixed order: Ethernet, Emergency, Infrastructure, Environment, Application, followed by the default rule.

  • Firewall rules are stateful and evaluated top-down; the first match wins, and the default rule can be set to allow or drop.

  • Groups can be static or dynamic; dynamic membership is driven by NSX tags, VM names, segments, or IP addresses, and groups are the match criteria in rules.

  • Spoof Guard and IP/MAC discovery prevent a VM from sending traffic with a source address different from the one learned for its vNIC.

  • Identity firewall uses Active Directory user and group identity so DFW rules can be based on who is logged in to the workload.

  • Distributed IDS/IPS and malware prevention run at the host level, and NSX Intelligence provides flow-based analysis of east-west traffic.

Quick reference

NSX Operations, Monitoring, and Troubleshooting

  • Traceflow injects a synthetic packet with chosen headers and reports each hop across hosts and edges, showing where a firewall or routing rule drops it.

  • The port connection tool shows which segment or switch port a VM vNIC is attached to and whether the attachment is up.

  • Packet capture can target a segment, a VM vNIC, or an Edge interface to confirm whether traffic arrives and leaves a node.

  • NSX Manager uses a get/set/del CLI syntax; a prepared ESXi host uses nsxcli for commands such as get logical-switches and get tunnel-ports.

  • Tunnel health is checked with tunnel-port and hostswitch status output; BFD between Edge nodes and Tier-0 peers detects failure and triggers failover.

  • Alarms appear in NSX Manager per node and per entity; syslog servers are configured per node to export logs centrally.

  • Support bundles for all nodes can be generated from the NSX Manager UI or CLI for log and configuration collection.

  • A 1600-byte path is verified with ping using the DF bit and a 1572-byte payload; fragmentation errors indicate an underlay MTU mismatch.