VCP-NV study materials
VCP-NV study resources

VCP-NV flashcards

VCP-NV · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

NSX Manager cluster size
Production high availability requires three NSX Manager nodes forming a cluster behind a single VIP; a single node is supported only for lab and evaluation deployments.
GENEVE encapsulation port
NSX overlay traffic is encapsulated in GENEVE, which uses UDP destination port 6081. The physical underlay must permit this between all transport nodes.
Overlay transport zone
Defines the span of GENEVE-backed segments. Hosts and edges in the same overlay transport zone can participate in the same logical switches.
Host transport node
An ESXi host prepared with NSX kernel modules and a hostswitch, providing the distributed data plane for segments and the distributed firewall.
Edge transport node
A VM or bare-metal appliance in an edge cluster that provides centralized services such as Tier-0 routing, NAT, load balancing, and VPN.
Uplink profile
A reusable object specifying teaming policy, active and standby uplinks, transport VLAN, and MTU applied to hostswitch uplinks on transport nodes.
Tier-1 distributed router
The downlink of a Tier-1 gateway is realized as a distributed router on every host, so routing between segments on one host stays local.
Transport node profile
Applied to a vSphere cluster to configure the same hostswitch (N-VDS or VDS 7.0) and uplink settings on all member ESXi hosts.
Edge node sizes
Small, Medium, Large, and X-Large, selected by throughput and feature needs; the size is fixed at deployment and changing it requires redeployment.
Compute manager registration
vCenter is registered to NSX Manager with credentials so NSX can inventory hosts and VMs and deploy Edge appliances into the compute environment.
TEP IP pool
A range of IP addresses assigned to tunnel endpoints on host and Edge transport nodes, used as the source for GENEVE overlay traffic.
NSX Manager backup
Configuration backups are sent to an FTP or SFTP server; restore requires an NSX Manager of the same or a compatible software version.
Upgrade start point
Upgrades begin with the NSX Manager cluster, which must be fully upgraded before host transport nodes or Edge nodes are upgraded.
Segment definition
A logical switch backed by GENEVE that VMs attach to; it lives in an overlay transport zone and is independent of physical VLANs.
Tier-0 gateway role
Provides north-south connectivity between the NSX domain and the physical network through the service routers of an attached edge cluster.
Tier-1 service router
Instantiated on the Edge only when a Tier-1 gateway has centralized services configured, such as NAT, load balancing, or gateway firewall.
Route advertisement
A Tier-1 advertises connected segments, static routes, NAT IPs, and load balancer VIPs up to its Tier-0 unless selectively disabled.
ECMP requirement
Equal-cost multipath on a Tier-0 gateway requires multiple Edge nodes in the edge cluster with equal-cost paths to upstream physical routers.
VLAN-backed segment
Maps a segment to a specific VLAN on the transport VLAN, used to connect workloads to physical networks without GENEVE encapsulation.
ARP suppression
The transport node answers ARP requests for known IP-to-MAC bindings on an overlay segment, reducing broadcast flooding across the network.
Distributed firewall point
DFW rules are enforced at the VM vNIC in the hypervisor kernel, so east-west traffic is filtered without leaving the host.
DFW rule categories
Evaluation order is Ethernet, Emergency, Infrastructure, Environment, Application; rules within a category are evaluated top-down with first match winning.
Gateway firewall
Enforced on the Edge service router, it filters north-south traffic and supports L7 features such as URL filtering and TLS inspection.
Security group membership
Groups can be static or dynamic, based on NSX tags, VM names, segments, or IP addresses, and their membership determines which firewall rules apply.
Spoof Guard
Blocks a VM from sending traffic with a source IP or MAC address different from the binding learned by IP discovery for that vNIC.
Identity firewall
Uses Active Directory user and group identity so distributed firewall rules can be enforced based on who is logged in to the workload.
Traceflow
Injects a synthetic packet with specified headers to trace its path across hosts and edges and show where a rule drops it.
Port connection tool
Shows the segment or switch port a VM vNIC is attached to and whether that attachment is currently up or down.
nsxcli on ESXi
The command-line interface available on a prepared ESXi host, used for commands such as get logical-switches and get tunnel-ports.
Edge BFD
Bidirectional forwarding detection between Edge nodes and Tier-0 peers detects peer failure quickly and triggers failover of centralized services.
MTU verification
Use ping with the DF bit and a 1572-byte payload to verify a 1600-byte path; fragmentation errors indicate an underlay MTU mismatch.
Support bundle