WA Water/Wastewater Operator flashcards
WA Water/Wastewater Operator · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Turbidity 95% rule
- Conventional and direct filtration systems must produce finished water at or below 0.3 NTU in at least 95% of monthly measurements, and no single sample may exceed 1 NTU.
- GWUDI
- Groundwater under the direct influence of surface water, meaning it is hydraulically connected to surface water and must be treated under surface water treatment rules.
- Lead action level
- The 90th percentile tap sample concentration of 0.015 mg/L for lead; exceeding it triggers corrosion control evaluation, public education, and additional monitoring.
- Nitrate MCL
- The maximum contaminant level for nitrate is 10 mg/L measured as nitrogen, set to prevent methemoglobinemia in infants.
- Coagulation
- A treatment step that neutralizes the negative surface charge on suspended particles so they can collide and stick together during flocculation.
- Flocculation velocity gradient
- The mixing intensity, typically 10 to 75 per second, applied with 15 to 45 minutes of detention to build settleable floc after rapid mix.
- Filter backwash
- Reversing flow through a filter to expand the bed about 20 to 50 percent and wash out captured solids, restoring headloss capacity.
- CT concept
- The product of disinfectant residual concentration and effective contact time, used to determine the log inactivation credit earned by a treatment process.
- Minimum distribution pressure
- Systems must maintain at least 20 psi throughout the distribution network under all flow conditions to prevent contamination from backflow.
- Residual disinfectant
- A detectable disinfectant concentration, typically at least 0.2 mg/L free chlorine, maintained throughout the distribution system to protect against microbial regrowth.
- Hazen-Williams C factor
- A pipe roughness coefficient used to compute head loss; values near 130 to 140 represent smooth new pipe and lower values represent rougher older mains.
- Air gap
- A physical separation between a potable water outlet and the flood level of a receiving vessel, providing the highest protection against backflow.
- Minimum sewer velocity
- Sanitary sewers are designed for at least 2 feet per second at design flow so solids stay suspended and the pipe self-cleans.
- Infiltration versus inflow
- Infiltration is groundwater entering through defective pipes and joints, while inflow is stormwater entering through direct connections such as roof drains.
- Manning's equation
- A formula relating flow to pipe slope, hydraulic radius, cross-sectional area, and a roughness coefficient n to size gravity sewers.
- Hydrogen sulfide corrosion
- Sulfide produced by anaerobic bacteria in sewers converts to sulfuric acid on wet concrete above the waterline, destroying the pipe crown.
- Pump affinity laws
- For a given impeller, flow changes with speed, head with the square of speed, and power with the cube of speed.
- Brake horsepower formula
- Pump power equals flow in gpm times head in feet times specific gravity, divided by 3960 times pump efficiency.
- Cavitation
- Vapor bubbles form and collapse in a pump when available NPSH is too low, causing noise, vibration, and damage to the impeller.
- Best efficiency point
- The flow at which a centrifugal pump operates with highest efficiency and lowest hydraulic loads; running far from it shortens equipment life.
- Motor full-load amps
- The current a motor draws at rated load and voltage, listed on the nameplate and used to size overload protection.
- Breakpoint chlorination
- The chlorine dose, near a 7.6 to 1 weight ratio to ammonia, beyond which free chlorine residual rises sharply after destroying chloramines.
- Chlorine demand
- The amount of chlorine consumed by reactions with organic and inorganic material before any free residual remains; dose equals demand plus desired residual.
- Chemical dose formula
- Dose in mg/L equals feed rate in pounds per day times 8.34 divided by plant flow in million gallons per day.
- Chloramine formation
- Free chlorine reacts with ammonia to form monochloramine and other species that are weaker disinfectants but persist longer in distribution systems.
- DPD method
- A colorimetric test using DPD indicator to measure free chlorine; subtracting free from total approximates the combined chlorine concentration.
- Nephelometric turbidity
- Turbidity measured by the light scattered at 90 degrees from a sample, reported in NTU and calibrated with formazin or approved standards.
- Jar test
- A bench-scale test that simulates rapid mix, flocculation, and settling at several chemical doses to select the coagulant dose for the plant.
- BOD5
- The oxygen consumed by microorganisms over five days at 20 degrees Celsius, used to measure biodegradable organic strength of wastewater.
- Consumer Confidence Report
- An annual water quality report that community water systems must deliver to customers by July 1, summarizing source, contaminants, and compliance.
- Tier 1 public notice
- Notification required within 24 hours for acute violations such as an MCL exceedance for nitrate or a situation posing immediate health risk.
- Lockout tagout
- A procedure that isolates and locks energy sources before maintenance so equipment cannot start unexpectedly, verified by testing for zero energy.
- Confined space entry permit
- A written authorization listing atmospheric test results, hazards, entrants, attendant, and rescue plan required before entering a permit-required confined space.