Wastewater Treatment Plant Operator study materials
Wastewater Treatment Plant Operator study resources

Wastewater Treatment Plant Operator cheat sheet

Wastewater Treatment Plant Operator · Keep the key ideas within reach.

Quick reference

Preliminary and Primary Treatment

  • Percent removal = (influent − effluent) ÷ influent × 100; applied to TSS, BOD5, and ammonia across every unit process.

  • Coarse bar screens have 1/4–1.5 in (6–38 mm) openings and fine screens 1/8 in (3 mm) or less; headloss rising above roughly 6 in signals the rack needs cleaning.

  • Grit has a specific gravity near 2.65 and a settling velocity of about 0.1 ft/s; grit chambers hold horizontal velocity near 1 ft/s so grit settles while organic solids stay suspended.

  • Aerated grit chambers typically provide 1–3 minutes of detention at peak flow and use a rolling roll to separate grit from organics.

  • Primary clarifier design: surface overflow rate 600–1,200 gpd/ft² at average flow, detention 1.5–2.5 h, weir loading 10,000–20,000 gpd/ft.

  • Expected primary removal is 50–65% TSS and 25–40% BOD5; rising blanket, carryover, or short-circuiting indicates hydraulic or solids-loading problems.

  • Solids loading rate = (influent TSS mg/L × flow MGD × 8.34) ÷ clarifier area in ft², reported as lb/ft²/day; typical design is 25–30 lb/ft²/day.

  • Settling regimes are Type I discrete, Type II flocculant, Type III zone (hindered), and Type IV compression; blanket depth is measured with a sludge judge or core sampler.

  • 1% solids equals 10,000 mg/L; dry tons/day = mg/L × MGD × 8.34 ÷ 2,000.

Quick reference

Secondary (Biological) Treatment

  • F/M = lb BOD5 applied per day ÷ lb MLSS (or MLVSS) in aeration; conventional 0.2–0.4, extended aeration 0.05–0.15, high-rate 0.4–1.5.

  • MCRT (SRT) = lb solids in the system ÷ lb solids leaving per day (waste sludge plus effluent solids); conventional 5–15 days, nitrifying systems commonly 10–20 days or more.

  • SVI = settled sludge volume (mL/L after 30-min settle of a 1-L sample) × 1,000 ÷ MLSS mg/L; 80–150 mL/g is good settling, above 200 suggests filamentous bulking.

  • RAS rates are commonly 0.5–1.5 times influent flow; return sludge from a well-formed blanket is typically 4,000–10,000 mg/L.

  • Hold DO at 1.5–2.5 mg/L for carbonaceous oxidation; nitrification needs about 2 mg/L DO, pH 7.0–8.5, and 7.14 mg/L alkalinity as CaCO3 per mg/L NH3-N oxidized.

  • Oxygen demand is 4.57 mg O2 per mg NH3-N nitrified; denitrification recovers roughly 2.86 mg O2 per mg NO3-N reduced.

  • Trickling filter loading is lb BOD5 per 1,000 ft³ of media per day: low-rate 5–25, high-rate 25–100; recirculation dilutes strength and helps control sloughing.

  • Trickling filter problems include media ponding, Psychoda (filter flies), and seasonal sloughing; facultative lagoons rely on algae-bacteria symbiosis with 20–180 day detention.

  • Clarifier troubleshooting: rising blanket from denitrification or short MCRT, cloudy effluent from young sludge or toxic shock, pinpoint floc from low F/M.

Quick reference

Tertiary and Advanced Treatment

  • Granular media filters are rated by hydraulic loading, typically 2–5 gpm/ft²; backwash runs 15–20 gpm/ft² with 20–30% bed expansion.

  • Membrane pore ranges: MF about 0.1–0.2 µm, UF about 0.01–0.1 µm, NF about 0.001 µm, and RO effectively non-porous, rejecting dissolved ions.

  • Flux is reported in gallons per square foot per day (gfd); recovery % = permeate ÷ feed × 100; a rising trans-membrane pressure at constant flux signals fouling.

  • Feedwater targets ahead of RO/NF are turbidity below 0.1 NTU and a silt density index (SDI15) below 5.

  • RO rejects 95–99% of dissolved salts; the concentrate stream must be managed by permit-approved disposal, deep-well injection, or evaporation.

  • Nutrient polishing options include anoxic denitrifying filters with external carbon, chemical phosphorus precipitation with alum or ferric salts, and effluent TP limits below 0.1 mg/L.

  • Chemical phosphorus removal typically requires roughly 1.5–2.5 mg of alum per mg of P removed; polymer is added to capture precipitated floc.

  • Membrane integrity is verified by pressure-decay (vacuum hold) tests and by permeate turbidity or particle counting.

Quick reference

Disinfection

  • CT = disinfectant residual (mg/L) × contact time (min); required CT increases as temperature falls and, for chlorine, as pH rises.

  • Free chlorine speciation: HOCl dominates and is far more biocidal below pH 7.5 (pKa ≈ 7.5 at 25°C); above pH 8 the less effective OCl⁻ dominates.

  • Chlorine demand = applied dose − residual after contact; breakpoint occurs near a Cl2:NH3-N weight ratio of about 7.6:1, beyond which free chlorine persists.

  • Dechlorination: about 1 mg/L SO2 (or roughly 1.5 mg/L sodium bisulfite) removes 1 mg/L free chlorine; sodium thiosulfate is used for small flows and sample quenching.

  • UV dose = intensity (mW/cm²) × exposure time (s), reported in mJ/cm²; wastewater disinfection typically uses 30–40 mJ/cm² at 254 nm and depends on UV transmittance and sleeve fouling.

  • Ozone is generated on site from dried air or oxygen at typical doses of 2–5 mg/L with 5–15 min contact; off-gas must be destroyed thermally or catalytically.

  • Contact chambers are designed for at least 30 minutes detention at peak flow with baffling to approach plug flow and limit short-circuiting.

  • Typical secondary effluent limits are a fecal coliform geometric mean of 200 cfu/100 mL with a 7-day maximum of 400 cfu/100 mL; dechlorination residual limits are commonly 0.01–0.05 mg/L.

Quick reference

Solids Handling and Biosolids Management

  • Gravity thickening raises waste activated sludge from about 0.5–1% to 3–5% solids at solids loadings of 20–30 lb/ft²/day and overflow rates of 400–1,000 gpd/ft².

  • Mesophilic anaerobic digestion runs at 35–37°C (95–98°F) with 15–20 day SRT; thermophilic runs near 55°C; VS loading is typically 0.1–0.2 lb VS/ft³/day unmixed and up to 0.4 mixed.

  • Normal volatile solids destruction is 40–60%; gas yield is 5.5–6.5 ft³ per lb VS destroyed at 60–65% methane and roughly 600–650 BTU/ft³.

  • Digester upset indicators: pH below 6.8, rising volatile acids with falling alkalinity, VA/alkalinity ratio above 0.3, and increasing CO2 in the gas.

  • Belt filter presses and centrifuges commonly produce 15–30% cake; polymer conditioning doses are typically 5–20 lb dry polymer per ton of dry solids.

  • Solids capture = lb dry solids in cake ÷ lb dry solids in feed × 100; well-run centrifuges and belt presses achieve 90–95% or better.

  • 40 CFR Part 503 governs biosolids: Class A (below 1,000 fecal coliform/g TS plus pathogen alternatives) versus Class B, vector attraction reduction, and nine pollutant limits.

  • Dry tons/day = mg/L × MGD × 8.34 ÷ 2,000; use the mass balance to check thickening, digestion, and dewatering performance.

  • Lime stabilization raises pH to 12 or above for 2 hours to reduce pathogens; composting and heat drying are alternatives that can produce Class A material.

Quick reference

Collection Systems and Pumping

  • Sanitary sewers should carry design flow at 2 ft/s or more to stay self-cleaning; Manning n is about 0.013 for concrete and 0.011 for PVC.

  • Manning's equation in English units: Q = (1.486/n) A R^(2/3) S^(1/2), with R = area ÷ wetted perimeter.

  • Infiltration is groundwater entering through defective pipes and joints; inflow is direct stormwater entry; together they form RDII and drive peak wet-weather flows.

  • Pump affinity laws: capacity varies with speed, head with speed squared, and power with speed cubed; impeller trimming follows similar relationships with diameter.

  • Wet-well cycling: inflow (gpm) = pump-out rate × run time ÷ total cycle time; minimum cycle time is set by the motor's allowable starts per hour.

  • Operating far left of the pump curve risks upthrust and overheating; far right risks cavitation and motor overload - compare NPSH available to NPSH required.

  • Air release and vacuum valves, surge relief, and thrust blocking protect force mains from water hammer during pump start and stop.

  • SSOs and CSOs must be reported to the state within the required time (often 24 hours) and logged with volume, duration, receiving water, and corrective action.

  • Smoke testing, dye testing, CCTV inspection, and flow monitoring are the standard methods for locating infiltration and inflow sources.

Quick reference

Process Control, Sampling, and Laboratory Analysis

  • BOD5 uses a 300-mL bottle incubated 5 days at 20°C in the dark; depletion must be at least 2 mg/L with at least 1 mg/L residual DO, or the sample must be diluted or seeded.

  • Seeded BOD: BOD = [(D1 − D2) − (B1 − B2) × f] ÷ P, where f is the seed volume ratio and P is the sample volume fraction.

  • TSS is retained on a glass-fiber filter (1.5 µm nominal) dried at 103–105°C; VSS is the portion lost on ignition at 550°C.

  • Pounds formula: lb/day = mg/L × MGD × 8.34; conversely mg/L = lb/day ÷ (MGD × 8.34).

  • Holding times: pH and chlorine residual are run immediately; BOD 48 h refrigerated; TSS 7 days; preserved ammonia 28 days.

  • A grab sample represents one moment; a flow-proportioned 24-hour composite represents average mass loading and is what permits usually require.

  • Reference methods: Standard Methods 5210 B for BOD, 2540 D for TSS, and 4500-NH3 for ammonia.

  • COD by 2-hour dichromate reflux approximates total oxidizable matter and typically runs 1.5–2.5 times BOD5 in raw wastewater.

  • Calibrate DO meters by Winkler titration or saturated air, and pH meters with 4.0/7.0/10.0 buffers, recording temperature compensation.

Quick reference

Equipment, Maintenance, and Instrumentation

  • Centrifugal pumps must be primed; running dry damages seals and wear rings, and cavitation (rattling, vibration, lost head) means NPSH available is below NPSH required.

  • Vibration analysis, lubricant analysis, and infrared thermography are predictive tools; a rising bearing vibration trend typically precedes failure.

  • Calibrate 4–20 mA loops with a signal generator: 4 mA = 0% and 20 mA = 100% of span; a live zero lets the system detect broken wiring.

  • pH probes need two- or three-point calibration and periodic cleaning; slow response usually indicates a fouled or coated bulb.

  • Rising blower discharge pressure with unchanged airflow points to diffuser or air-header plugging; check inlet filters as well.

  • Motor checks: voltage imbalance under 1%, balanced phase currents, insulation resistance, and running amps below nameplate full-load amps.

  • Lockout/tagout per 29 CFR 1910.147 precedes any repair on pumps, blowers, conveyors, or mixers.

  • Flow metering: magnetic meters need a full pipe and adequate conductivity, ultrasonic meters need a clean acoustic path, and open-channel flow uses a weir or Parshall flume with a stage reading.

  • Lubricate at manufacturer intervals; over-lubricating motor bearings causes overheating and is as damaging as under-lubrication.

Quick reference

Safety, Confined Spaces, and Hazardous Conditions

  • Permit-required confined space entry (29 CFR 1910.146) requires pre-entry and continuous atmospheric testing, a signed permit, entrant, attendant, entry supervisor, and rescue provisions.

  • Entry atmosphere limits: oxygen 19.5–23.5%, flammable gas below 10% LEL, hydrogen sulfide below 10 ppm, and carbon monoxide below 35 ppm (or stricter site limits).

  • H2S is heavier than air, deadens the sense of smell at higher concentrations, and has an IDLH of 100 ppm; methane LEL is 5% and UEL 15%; chlorine IDLH is 10 ppm.

  • Never enter a space to rescue a downed worker without respiratory protection and backup - most confined-space fatalities are untrained would-be rescuers.

  • Chlorine gas is heavier than air and forms hydrochloric acid with moisture; respond with SCBA and a chlorine repair kit, keep cylinders away from heat, and never spray water on a leak.

  • Fall protection is required at 4 ft in general industry; hatches, guardrails, and grating over wet wells must be secured before opening.

  • Methane, hydrogen sulfide, and carbon monoxide are the classic wet well and digester hazards; use intrinsically safe multi-gas meters calibrated before each use.

  • Electrical work requires GFCI protection, lockout/tagout, and NFPA 70E arc-flash PPE; never work alone on energized equipment.

  • Chemical handling: add acid to water, follow the SDS, and keep an eyewash and safety shower within about 10 seconds' travel of feed areas.

Quick reference

Regulations, Permits, Reporting, and Records

  • The NPDES permit (CWA §402, 40 CFR Part 122) sets effluent limits, monitoring requirements, and reporting; the DMR is submitted monthly or as the permit specifies.

  • NPDES records must be kept at least 3 years (longer if compliance action is pending); biosolids records under Part 503 are kept 5 years.

  • Bypasses, upsets, and noncompliance require oral notification as soon as practicable (commonly within 24 hours) followed by written notice within 5 days.

  • SSOs must be reported to the state and often to the public; CSOs are addressed through the nine minimum controls and a long-term control plan.

  • 40 CFR Part 503 sets biosolids pollutant limits, pathogen reduction classes, vector attraction reduction, and management and reporting practices.

  • Whole effluent toxicity (WET) tests use indicator species to detect unmeasured toxics; a failure triggers a toxicity identification evaluation (TIE).

  • The Clean Water Act (1972) established technology-based (BPT/BAT) and water-quality-based limits along with antidegradation policy.

  • Every exceedance must appear on the DMR even when caused by collection system or treatment problems; falsifying a report is a criminal violation.

  • Operator certification is a state requirement with grade levels tied to facility classification, and renewal requires continuing education.