Wastewater Treatment Plant Operator flashcards
Wastewater Treatment Plant Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Surface overflow rate
- Primary clarifier loading expressed as flow in gallons per day divided by clarifier surface area in square feet; typical design values are 600 to 1,200 gpd/ft².
- Grit settling velocity
- Grit with specific gravity near 2.65 is removed by holding a horizontal velocity near 1 ft/s so grit settles while lighter organic solids remain suspended.
- Type III zone settling
- Hindered settling in which particles form a blanket that drops as a mass at a constant rate; the interface depth tracks clarifier solids handling capacity.
- Primary clarifier solids loading
- Pounds of influent suspended solids per square foot of clarifier area per day, calculated as mg/L × MGD × 8.34 divided by area; typical design is 25 to 30 lb/ft²/day.
- Food to microorganism ratio
- Pounds of BOD5 applied per day divided by pounds of MLSS or MLVSS in the aeration tank; conventional activated sludge runs about 0.2 to 0.4.
- Mean cell residence time
- Pounds of solids in the aeration system divided by pounds of solids leaving per day in waste sludge and effluent; it sets sludge age and whether nitrification occurs.
- Sludge volume index
- Settled sludge volume in milliliters per liter after 30 minutes times 1,000 divided by MLSS in mg/L; values of 80 to 150 indicate good settling.
- Nitrification oxygen demand
- Oxidizing ammonia to nitrate consumes about 4.57 mg of oxygen per mg of ammonia nitrogen and 7.14 mg/L of alkalinity as CaCO3 per mg/L oxidized.
- Trickling filter organic loading
- Pounds of BOD5 applied per day per 1,000 cubic feet of filter media; low-rate filters run 5 to 25 and high-rate filters 25 to 100.
- Membrane flux
- Permeate flow per unit membrane area, usually expressed as gallons per square foot per day; falling flux at constant pressure indicates fouling or scaling.
- Reverse osmosis salt rejection
- The percentage of dissolved salts excluded from permeate, typically 95 to 99 percent; feed water should have low turbidity and a silt density index below 5.
- Denitrifying filter
- An anoxic granular media filter that converts nitrate to nitrogen gas using an added carbon source, applied for tertiary total nitrogen polishing.
- CT value
- Disinfectant residual concentration in mg/L multiplied by contact time in minutes; the required CT increases as water temperature falls and pH rises.
- Breakpoint chlorination
- The chlorine dose, near a chlorine-to-ammonia-nitrogen weight ratio of 7.6 to 1, beyond which a free chlorine residual begins to persist.
- UV transmittance
- The fraction of 254 nm light passing through the water, reported as percent; low transmittance from color or particles reduces the delivered UV dose.
- Volatile solids destruction
- The percentage of volatile solids fed to a digester that is converted to gas and destroyed; well-operated anaerobic digesters achieve 40 to 60 percent.
- Digester volatile acids ratio
- Volatile acids divided by alkalinity in mg/L; a ratio above about 0.3 signals impending digester upset along with falling pH and rising carbon dioxide.
- Biosolids Class A
- Biosolids treated below 1,000 fecal coliform per gram dry solids and meeting alternative pathogen and vector attraction reduction requirements of 40 CFR Part 503.
- Infiltration versus inflow
- Infiltration is groundwater seeping through defective pipes and joints; inflow is stormwater entering directly through improper connections, catch basins, or manhole covers.
- Self-cleaning sewer velocity
- A minimum velocity of about 2 feet per second at design flow keeps grit and solids moving and prevents deposition in sanitary sewers.
- Pump affinity laws
- For a centrifugal pump, capacity varies directly with speed, head with the square of speed, and power with the cube of speed.
- BOD5 incubation requirements
- Sample incubated 5 days at 20 degrees Celsius in the dark; depletion must be at least 2 mg/L with at least 1 mg/L residual oxygen or the test is invalid.
- Pounds formula
- Pounds per day of a substance equals concentration in mg/L times flow in million gallons per day times 8.34, converting lab results into mass loadings.
- Composite versus grab sample
- A grab sample captures conditions at one moment; a flow-proportioned composite collected over 24 hours represents average loading and is used for permit reporting.
- TSS filter drying temperature
- Suspended solids are retained on a glass-fiber filter, dried at 103 to 105 degrees Celsius, and weighed; volatile solids are the portion lost on ignition at 550 degrees.
- Pump cavitation cause
- Vapor bubbles form when available net positive suction head falls below required; symptoms include rattling noise, vibration, and reduced head and capacity.
- Four to twenty milliamp signal
- An analog instrument loop in which 4 mA represents zero percent and 20 mA represents 100 percent of span, providing a live zero to detect broken wiring.
- Permit-required confined space
- A space with limited entry containing a hazardous atmosphere, engulfment, or other serious hazard; entry requires a permit, atmospheric testing, an attendant, and rescue provisions.
- Hydrogen sulfide exposure limits
- Hydrogen sulfide is heavier than air with a 100 ppm IDLH; olfactory fatigue deadens the smell, so entry decisions must rely on calibrated meters, not odor.
- Oxygen deficient atmosphere
- Any atmosphere below 19.5 percent oxygen is oxygen deficient and requires supplied-air respiratory protection; permit entry is prohibited without it.
- Discharge monitoring report
- The periodic report of effluent monitoring results submitted under an NPDES permit; it must be signed by the authorized official and retained at least three years.
- Part 503 biosolids rule
- Federal rule governing biosolids quality, including ceiling and exceptional quality metal limits, pathogen reduction classes, vector attraction reduction, and reporting requirements.