WI Plumber · Get comfortable with the vocabulary.

Personal protective equipment (PPE)

Gear worn to protect a worker from job-site hazards, such as safety glasses, gloves, hard hats, respirators, and hearing protection. Employers must require it wherever hazards are present and enforce its use.

Related: Trench protective system, Confined space
Trench protective system

A method that keeps soil from collapsing into an excavation, such as sloping, benching, shoring, or a trench box. It is required when workers enter trenches at the depths set by safety rules.

Related: Confined space, Personal protective equipment (PPE)
Confined space

An area with limited entry or exit that is not built for continuous occupancy and may hold hazardous air. Entry may require air testing, ventilation, an attendant, and a written permit.

Related: Personal protective equipment (PPE), Trench protective system
Combustion air

Air supplied to a fuel-burning appliance so gas or oil burns completely. Too little air can cause carbon monoxide and poor draft, so code sets opening sizes and allowable sources.

Related: Confined space
Potable water

Water that is safe for drinking, cooking, and bathing because it meets health standards. Plumbing systems must protect it from contamination through approved materials, testing, and backflow control.

Related: Cross-connection, Backflow
Cross-connection

Any actual or potential link between the potable water system and a source of contamination or pollution. Cross-connections must be removed or protected by an approved backflow preventer.

Related: Backflow, Air gap, Reduced pressure zone backflow preventer (RPZ)
Backflow

The unwanted reversal of water flow in a piping system, which can pull contaminants into potable lines. It results from backpressure or backsiphonage and is controlled with air gaps and backflow preventers.

Related: Cross-connection, Air gap, Vacuum breaker
Air gap

The unobstructed vertical distance between a water supply outlet and the flood level rim of the receiving fixture. It is the most reliable backflow protection and must meet a minimum distance.

Related: Backflow, Reduced pressure zone backflow preventer (RPZ)
Reduced pressure zone backflow preventer (RPZ)

A testable assembly with two check valves and a relief valve that discharges if pressure reverses. It protects high-hazard connections and must be tested on the schedule the code requires.

Related: Backflow, Air gap, Cross-connection
Vacuum breaker

A device that admits air into piping to stop backsiphonage when pressure drops. Atmospheric and pressure types are chosen for hose connections and fixtures based on the hazard level.

Related: Backflow, Cross-connection
Water service pipe

The pipe that carries potable water from the water main or private well to the building. It ends at the meter or at the first fitting inside the building, depending on local rules.

Related: Potable water, Pressure-reducing valve
Pressure-reducing valve

A device that lowers incoming water pressure to a safe, usable level for the building. It protects fixtures and appliances from excess pressure and often requires a thermal expansion tank downstream.

Related: Thermal expansion tank, Water service pipe
Thermal expansion tank

A tank with a trapped air charge that absorbs the extra volume of water as it heats in a closed system. It limits pressure rise and protects the water heater and piping.

Related: Pressure-reducing valve, Temperature and pressure relief valve (T&P)
Fixture unit

A number assigned to a plumbing fixture that represents its probable drainage load or water demand. Fixture units are used to size drains, vents, and water supply piping.

Related: Building drain, Building sewer
Trap seal

The water held in the curved dip of a trap that blocks sewer gas from entering the building. It must be kept at the required depth and protected from siphonage and evaporation.

Related: P-trap, Trap primer, Air admittance valve
P-trap

A U-shaped trap with a water seal located directly below or near a fixture drain. Its outlet arm turns upward to connect to the drain and vent system.

Related: Trap seal, Cleanout
Vent stack

A vertical pipe that supplies air to a drainage system and carries sewer gas outdoors above the roof. It protects trap seals from pressure changes caused by draining fixtures.

Related: Wet vent, Air admittance valve, Trap seal
Wet vent

A pipe that serves as a drain for one fixture and as a vent for another. Wet venting is permitted only within the size, length, and arrangement limits set by code.

Related: Vent stack, Fixture unit
Air admittance valve

A one-way valve that opens to admit air when a fixture drains and closes to keep sewer gas inside the system. It may replace certain vent connections where code allows.

Related: Vent stack, Trap seal
Building drain

The lowest pipe inside a building that receives soil and waste from fixture drains. It runs to the building wall and connects to the building sewer.

Related: Building sewer, Cleanout, Fixture unit
Building sewer

The pipe outside the building foundation that carries sewage from the building drain to the public sewer or private disposal system. It is usually the property owner's responsibility.

Related: Building drain, Cleanout, Grease interceptor
Cleanout

An accessible opening with a removable cap that lets a plumber clear a blockage in a drain or sewer line. Code requires them at certain locations, distances, and changes in direction.

Related: Building drain, Building sewer
Grease interceptor

A tank that slows wastewater so fats, oils, and grease float and are trapped before flow reaches the sewer. It must be correctly sized and pumped out on a regular schedule.

Related: Building sewer, Cleanout
Sewage ejector

A pump and basin that lift wastewater from a low point, such as a basement, up to a gravity drain or sewer. Unlike a sump pump, it is built to handle solids.

Related: Building drain, Building sewer
Slope (drainage)

The downward pitch of a drain pipe, stated as inches of fall per foot of run. Correct slope keeps solids moving while limiting standing water and allowing proper venting.

Related: Building drain, Fixture unit
Floor drain

A drain set into a floor that collects surface water and spills and connects to the drainage system through a trap. Its trap seal often needs protection from evaporation.

Related: Trap primer, Trap seal
Trap primer

A device or connection that adds a small amount of water to a trap to replace what evaporates. It keeps the seal intact for floor drains that rarely receive water.

Related: Trap seal, Floor drain
Temperature and pressure relief valve (T&P)

A safety valve on a water heater that opens when temperature or pressure gets too high. It must be piped to a safe discharge point and never capped or plugged.

Related: Thermal expansion tank
Fixture fitting

A device that controls or directs water at a fixture, such as a faucet, flush valve, or shower valve. It must be listed and installed to prevent backflow and scalding.

Related: Air gap, Vacuum breaker
Accessible fixture

A fixture designed and installed so people with disabilities can use it, meeting reach, clearance, and height rules. Examples include lowered lavatories and flush controls within reach range.

Related: Fixture fitting
Lead-free

Describes plumbing materials that meet the low-lead limit set by federal and state law for pipe, solder, and fittings. Lead-free solder and flux are required on potable water systems.

Related: Potable water, Fixture fitting
Plumbing permit

Official approval from the local authority to install or alter plumbing work. It triggers required inspections and must be obtained before work starts, except for listed minor repairs.

Related: Rough-in, Hydrostatic test, Master plumber
Master plumber

A licensed plumber who has met experience and testing requirements and may run a plumbing business, obtain permits, and supervise plumbing work in Wisconsin.

Related: Journeyman plumber, Plumbing permit
Journeyman plumber

A licensed plumber who may perform plumbing work under a master plumber's supervision but cannot contract for work or hold the plumbing business license.

Related: Master plumber
SPS 382 (Wisconsin Plumbing Code)

The Wisconsin administrative code chapter covering design, installation, and maintenance of plumbing systems. It is enforced by the Department of Safety and Professional Services and local authorities.

Related: Plumbing permit, Master plumber
Rough-in

The stage when pipes are installed in walls and floors before fixtures and finishes are put in. A rough-in inspection must pass before the work is covered.

Related: Plumbing permit, Hydrostatic test
Hydrostatic test

A pressure test that fills a piping system with water to check for leaks before it is covered or placed in service. Test pressures and durations follow code requirements.

Related: Rough-in, Plumbing permit