ABC Wastewater Collection Class II study materials
ABC Wastewater Collection Class II study resources

ABC Wastewater Collection Class II cheat sheet

ABC Wastewater Collection Class II · Keep the key ideas within reach.

Quick reference

Collection System Operations and Maintenance

  • Sewer cleaning methods: hydraulic (flushing), mechanical (rodding, augering), and chemical; choose based on pipe size, blockage type, and access.

  • Preventive maintenance schedules: inspect and clean lines on a frequency based on pipe material, age, slope, and history; typical frequencies range from monthly to every 5 years.

  • Root control: use mechanical cutting or chemical foaming; repeat as needed, especially in areas with mature trees.

  • Grease control: implement grease trap ordinances, public education, and regular inspection of food service establishments.

  • Infiltration and inflow (I/I): identify via smoke testing, dye testing, and flow monitoring; repair defective pipes and manholes.

  • Manhole inspection: check for cracks, corrosion, inflow sources, and proper cover fit; repair or replace as needed.

  • Safety: follow confined space entry procedures for manholes and wet wells; use gas monitoring and ventilation.

  • Recordkeeping: maintain accurate records of maintenance activities, inspections, and repairs for asset management and regulatory compliance.

  • Emergency response: have a plan for sanitary sewer overflows (SSOs), including containment, cleanup, and public notification.

Quick reference

Sewers, Lift Stations, and Pumping Equipment

  • Sewer types: sanitary, storm, and combined; sanitary carries wastewater to treatment, storm carries runoff, combined carries both.

  • Lift station components: wet well, pumps, motors, controls, valves, and emergency power; designed to lift wastewater when gravity flow is not possible.

  • Pump types: centrifugal, positive displacement, and submersible; selection depends on flow, head, and solids handling.

  • Pump maintenance: regular inspection of impellers, seals, bearings, and check valves; monitor vibration and temperature.

  • Wet well cleaning: remove grit and debris to prevent pump clogging and reduce wear.

  • Odor control: use covers, ventilation, and chemical addition (e.g., hydrogen peroxide, ferrous chloride) to reduce H2S.

  • Emergency power: test generators regularly; ensure automatic transfer switches function properly.

  • Level controls: maintain float switches, ultrasonic sensors, and pressure transducers; calibrate as needed.

Quick reference

Safety and Confined Space Entry

  • Confined space definition: limited entry/exit, not designed for continuous occupancy, and large enough to enter; includes manholes, wet wells, and tanks.

  • Entry permit required for permit-required confined spaces; permit includes hazards, atmospheric testing, ventilation, and rescue plan.

  • Atmospheric testing order: test oxygen first (19.5-23.5%), then flammables (<10% LEL), then toxics (H2S <10 ppm, CO <35 ppm).

  • Ventilation: use forced air blowers before and during entry; test atmosphere continuously.

  • Rescue: trained attendant outside; retrieval systems (tripod, winch) for non-entry rescue; entry rescue only by trained personnel.

  • Personal protective equipment (PPE): hard hat, safety glasses, gloves, steel-toe boots, and respiratory protection as needed.

  • Lockout/tagout: isolate energy sources (pumps, mixers) before entry; verify zero energy.

  • Hazard communication: know chemical hazards (H2S, methane, chlorine) and use appropriate monitoring and PPE.

Quick reference

Wastewater Flow, Hydraulics, and Capacity

  • Flow measurement: use weirs, flumes, or flow meters; calibrate regularly.

  • Manning's equation: Q = (1.486/n) * A * R^(2/3) * S^(1/2) for open channel flow (English units).

  • Pipe capacity: Q = A * V; velocity should be between 2 ft/s (scouring) and 10 ft/s (erosion) for sanitary sewers.

  • Slope: minimum slope for 8-inch pipe is typically 0.4% (0.004 ft/ft) to maintain self-cleansing velocity.

  • Infiltration/inflow: peak flows can exceed dry weather flow by 3-5 times; design capacity must account for this.

  • Hydraulic grade line (HGL): represents energy grade; must be below manhole rim to prevent surcharging.

  • Pump curves: system curve intersects pump curve at operating point; adjust impeller or speed to change flow.

  • Capacity assessment: use flow monitoring and modeling to identify bottlenecks and plan upgrades.

Quick reference

Inspection, Testing, and Rehabilitation

  • CCTV inspection: identifies defects (cracks, roots, offsets, infiltration); record and code per NASSCO PACP.

  • Smoke testing: blows smoke into sewer to find inflow sources; notify public and fire department beforehand.

  • Dye testing: confirms connection of illegal drains or inflow sources; use non-toxic dye.

  • Leak testing: low-pressure air test or water exfiltration test for new or repaired pipes.

  • Rehabilitation methods: CIPP (cured-in-place pipe), slip lining, pipe bursting, and spot repairs.

  • Manhole rehabilitation: use cementitious liners, epoxy, or polyurethane to seal and restore structure.

  • Trenchless technologies: minimize excavation and disruption; suitable for urban areas.

  • Quality assurance: verify rehabilitation by post-inspection (CCTV) and testing.

Quick reference

Regulations, Permits, and Reporting

  • NPDES permit: required for discharge from wastewater treatment plants; includes effluent limits and monitoring requirements.

  • SSO reporting: report sanitary sewer overflows to state agency within specified time (often 24 hours); include volume, location, and corrective actions.

  • Collection system permits: some states require permits for collection systems (e.g., California SSO Reduction Program).

  • Pretreatment regulations: 40 CFR Part 403; local limits for industrial users; permits and monitoring.

  • Biosolids regulations: 40 CFR Part 503; classify and manage biosolids according to pathogen and vector attraction reduction.

  • Operator certification: required by state; Class II certification for collection system operators.

  • Recordkeeping: retain monitoring records for at least 3 years (or longer per permit).

  • Public notification: for permit violations and SSOs, notify public and affected parties as required.

Quick reference

Math and Calculations

  • Flow rate: Q = V * A; convert units (1 cfs = 448.8 gpm; 1 MGD = 1.547 cfs).

  • Detention time: t = Volume / Flow; ensure consistent units.

  • Velocity: V = Q / A; for circular pipe flowing full, A = π * (D/2)^2.

  • Slope: S = (elevation difference) / (horizontal distance); express as ft/ft or percent.

  • Pump horsepower: HP = (Q * H * SG) / (3960 * efficiency) for centrifugal pumps (Q in gpm, H in feet).

  • Chemical dose: lbs = (concentration, mg/L) * (volume, MG) * 8.34.

  • Population equivalent: BOD5 contribution per person = 0.17 lb/day; use for loading calculations.

  • Unit conversions: 1 cubic foot = 7.48 gallons; 1 gallon = 8.34 lbs (water).

  • Area of circle: A = π * r^2; circumference: C = π * D.

Quick reference

Pretreatment, Grease, and Odor Control

  • Pretreatment program: controls industrial discharges to protect treatment plant and receiving waters; includes permits, monitoring, and enforcement.

  • Local limits: developed to prevent pass-through, interference, and sludge contamination; based on plant capacity and receiving stream.

  • Grease trap/interceptor: required for food service establishments; size based on flow and retention time; maintain regularly.

  • FOG (fats, oils, grease) control: public education, ordinance, and inspection; prevent blockages and SSOs.

  • Odor control methods: chemical addition (chlorine, hydrogen peroxide, ferrous salts), biofilters, and covers.

  • Hydrogen sulfide (H2S) control: reduce sulfide generation by minimizing detention time, adding nitrate, or using iron salts.

  • Corrosion control: H2S converts to sulfuric acid, damaging concrete; use corrosion-resistant liners or coatings.

  • Monitoring: sample industrial discharges for pH, BOD, TSS, metals, and toxic organics as required by permit.

Quick reference

Recordkeeping, Asset Management, and Public Relations

  • Asset management: inventory assets, assess condition, prioritize maintenance, and plan capital improvements.

  • Computerized maintenance management system (CMMS): track work orders, inventory, and maintenance history.

  • Recordkeeping: maintain as-builts, inspection records, maintenance logs, and monitoring data; retain per regulations.

  • Public relations: communicate with public about projects, SSOs, and rates; use door hangers, websites, and public meetings.

  • Customer service: respond promptly to complaints (odors, backups); document and follow up.

  • Emergency notification: use reverse 911, social media, and signage to inform public of SSOs or health hazards.

  • Rate setting: ensure sufficient revenue for operation, maintenance, and capital improvements.

  • Performance measurement: track SSOs, backups, inspection completion, and customer complaints to improve service.