ABC Wastewater Collection Class II flashcards
ABC Wastewater Collection Class II · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Confined space definition
- A space with limited entry/exit, not designed for continuous occupancy, and large enough for entry; examples include manholes, wet wells, and tanks.
- Atmospheric testing order
- Test oxygen first (19.5-23.5%), then flammables (<10% LEL), then toxics (H2S <10 ppm, CO <35 ppm) before and during confined space entry.
- Entry permit
- A document required for permit-required confined space entry that identifies hazards, atmospheric testing results, ventilation, PPE, and rescue plan.
- Lockout/tagout
- Procedure to isolate energy sources (pumps, mixers) before maintenance or entry; verify zero energy to prevent accidental startup.
- Manning's equation
- Q = (1.486/n) * A * R^(2/3) * S^(1/2) for open channel flow in English units; used to calculate flow in sewers.
- Self-cleansing velocity
- Minimum flow velocity of about 2 ft/s in sanitary sewers to prevent solids deposition; maximum velocity about 10 ft/s to avoid erosion.
- Infiltration and inflow
- Infiltration is groundwater entering sewers through defects; inflow is stormwater entering through direct connections; both increase flow and require rehabilitation.
- Hydraulic grade line
- The line representing the energy grade of flowing water; must be below manhole rim to prevent surcharging in gravity sewers.
- CCTV inspection
- Closed-circuit television camera used to inspect sewer interiors; identifies cracks, roots, offsets, and infiltration; record and code defects.
- Smoke testing
- Blows smoke into sewers to locate inflow sources; notify public and fire department beforehand to avoid false alarms.
- CIPP rehabilitation
- Cured-in-place pipe: a liner impregnated with resin is inserted and cured to form a new pipe within the old one; trenchless method.
- NPDES permit
- National Pollutant Discharge Elimination System permit required for wastewater discharges; includes effluent limits, monitoring, and reporting requirements.
- SSO reporting
- Sanitary sewer overflows must be reported to the state agency within a specified time (often 24 hours); include volume, location, and corrective actions.
- Pretreatment program
- Local program controlling industrial discharges to protect treatment plant, workers, and receiving waters; includes permits, monitoring, and enforcement.
- Grease trap maintenance
- Regular removal of fats, oils, and grease from interceptors prevents blockages and SSOs; frequency depends on use and size.
- Odor control methods
- Chemical addition (chlorine, hydrogen peroxide, ferrous salts), biofilters, and covers reduce odors from sewers and treatment plants.
- Detention time formula
- t = Volume / Flow; ensure consistent units (e.g., gallons and gallons per day) to calculate time in days.
- Flow rate conversion
- 1 cubic foot per second (cfs) = 448.8 gallons per minute (gpm); 1 million gallons per day (MGD) = 1.547 cfs.
- Pump horsepower formula
- HP = (Q * H * SG) / (3960 * efficiency) for centrifugal pumps; Q in gpm, H in feet, SG = specific gravity.
- Chemical dose formula
- lbs = (concentration, mg/L) * (volume, MG) * 8.34; used to calculate chemical feed for treatment.
- Lift station purpose
- Lifts wastewater when gravity flow is not possible; includes wet well, pumps, controls, and emergency power.
- Pump maintenance
- Regular inspection of impellers, seals, bearings, and check valves; monitor vibration and temperature to prevent failures.
- Wet well cleaning
- Remove grit and debris to prevent pump clogging and reduce wear; schedule based on accumulation.
- Emergency power testing
- Test generators regularly and ensure automatic transfer switches function; critical for lift stations during power outages.
- Preventive maintenance scheduling
- Inspect and clean sewers on a frequency based on pipe material, age, slope, and history; ranges from monthly to every 5 years.
- Root control
- Use mechanical cutting or chemical foaming to remove roots from sewers; repeat as needed, especially near mature trees.
- SSO emergency response
- Have a plan for sanitary sewer overflows: contain, clean up, notify public and regulators, and document corrective actions.
- Asset management
- Inventory assets, assess condition, prioritize maintenance, and plan capital improvements to sustain collection system performance.
- CMMS
- Computerized maintenance management system: tracks work orders, inventory, and maintenance history for efficient operations.
- Public notification
- Inform public of SSOs, projects, or health hazards using door hangers, websites, social media, and public meetings.
- Record retention
- Retain monitoring records, maintenance logs, and inspection reports for at least 3 years or longer as required by permit.
- Biosolids regulations
- 40 CFR Part 503 governs biosolids management, including pathogen reduction and vector attraction reduction requirements.