AEE Certified Energy Manager (CEM) flashcards
AEE Certified Energy Manager (CEM) · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- ASHRAE 90.1
- ASHRAE Standard 90.1 sets minimum energy efficiency requirements for commercial and high-rise residential buildings, excluding low-rise residential. It covers envelope, HVAC, lighting, power, and service water heating.
- IECC scope
- The International Energy Conservation Code establishes minimum energy efficiency provisions for residential and commercial buildings. Jurisdictions adopt it into law and may amend it locally.
- ASHRAE 62.1
- ASHRAE Standard 62.1 specifies minimum ventilation rates and indoor air quality requirements for commercial buildings to protect occupant health and comfort.
- Power factor formula
- Power factor equals real power in kW divided by apparent power in kVA. It ranges from 0 to 1 for sinusoidal loads and indicates how effectively current does useful work.
- Three-phase power equation
- For a balanced three-phase load, real power in kW equals the square root of three times line-to-line voltage times current times power factor, divided by 1,000.
- Motor efficiency
- Motor efficiency is shaft output power divided by electrical input power, expressed as a percentage. It varies with load and typically peaks near 75 to 100 percent of rated load.
- Affinity laws for fans
- For centrifugal fans, flow varies directly with speed, pressure varies with speed squared, and power varies with speed cubed, assuming constant system and air density.
- Commissioning definition
- Commissioning is a documented quality-assurance process that verifies building systems are designed, installed, functionally tested, and capable of operating according to the owner's project requirements.
- Retrocommissioning
- Retrocommissioning applies the commissioning process to existing buildings not previously commissioned, focusing on identifying and correcting operational problems and low-cost energy-saving opportunities.
- Preventive maintenance
- Preventive maintenance is scheduled, time-based or usage-based servicing of equipment to reduce failures and maintain efficiency, such as filter changes, belt inspection, and lubrication.
- ASHRAE Level 1 audit
- A Level 1 energy audit is a walk-through survey that identifies obvious energy-saving opportunities, provides a rough estimate of costs and savings, and helps scope further analysis.
- Energy use index
- Energy use index divides annual building energy consumption by conditioned floor area, commonly expressed as kBtu per square foot per year or kWh per square meter per year.
- Heating degree days
- Heating degree days quantify how much average daily temperature falls below a base temperature, typically 65 degrees Fahrenheit, and are used to normalize heating energy use to weather.
- IPMVP Option C
- IPMVP Option C measures savings for an entire facility using whole-building utility meter data, with adjustments for weather and other changes, and is suited to multifaceted retrofits.
- CHP total efficiency
- Combined heat and power total efficiency equals useful electrical output plus recovered useful thermal output, divided by fuel energy input, often reaching 60 to 80 percent.
- CHP prime movers
- Common CHP prime movers include reciprocating engines, gas turbines, microturbines, steam turbines, and fuel cells. Each differs in capacity, electric efficiency, and usable heat grade.
- Solar PV yield
- Estimated annual PV energy equals system direct-current capacity times peak sun hours times performance ratio. Performance ratio accounts for inverter, wiring, soiling, and temperature losses.
- Sensible heat equation
- In inch-pound units, sensible cooling load in Btu per hour approximately equals 1.08 times airflow in cubic feet per minute times the dry-bulb temperature difference.
- Chiller kW per ton
- Chiller efficiency in kW per ton equals 12 divided by EER, or 3.517 divided by COP. Lower values indicate better full-load efficiency.
- Air-side economizer
- An air-side economizer uses cool outdoor air instead of mechanical cooling when outdoor air enthalpy or temperature is below the return air condition, reducing compressor energy.
- Fan affinity laws
- For a centrifugal fan, airflow is proportional to speed, static pressure to speed squared, and shaft power to speed cubed, so modest speed reductions yield large energy savings.
- PID control
- PID control combines proportional, integral, and derivative actions. Proportional responds to current error, integral eliminates offset, and derivative damps response to changing error.
- Demand-controlled ventilation
- Demand-controlled ventilation modulates outdoor air intake based on measured occupancy indicators such as carbon dioxide concentration, reducing ventilation energy when spaces are lightly occupied.
- BACnet protocol
- BACnet is an open building automation and control communications protocol that enables interoperable data exchange among HVAC, lighting, and other building systems from different manufacturers.
- Thermal energy storage
- Thermal energy storage shifts heating or cooling production to off-peak periods by storing chilled water, ice, or phase-change material for later discharge, reducing demand charges and chiller size.
- Ice storage latent heat
- Ice thermal storage uses the latent heat of fusion, about 144 British thermal units per pound, to store cooling energy with a smaller tank volume than chilled-water storage.
- Full versus partial storage
- Full storage meets the entire peak cooling load from storage; partial storage uses storage plus operating chillers. Partial storage typically lowers first cost and chiller capacity.
- Luminous efficacy
- Luminous efficacy is visible light output in lumens divided by electrical input power in watts, expressed as lumens per watt. Higher efficacy means more light per unit energy.
- Lighting power density
- Lighting power density equals installed lighting watts divided by floor area, typically watts per square foot. Energy codes set maximum allowances by space type.
- Daylighting photosensor control
- A daylighting photosensor control dims or switches electric lighting in response to available daylight, reducing lighting energy while maintaining target illuminance in the space.
- Energy savings performance contract
- An energy savings performance contract is an agreement in which an energy service company implements efficiency measures and guarantees savings that repay project costs over the contract term.
- M&V savings equation
- Verified savings equal baseline energy use minus reporting-period energy use, adjusted for changes in weather, occupancy, or other agreed conditions that affect energy use.