AEE Certified Energy Manager (CEM) study materials
AEE Certified Energy Manager (CEM) study resources

AEE Certified Energy Manager (CEM) study guide

AEE Certified Energy Manager (CEM) · Work through your exam, one topic at a time.

The Certified Energy Manager (CEM®) is a professional credential awarded by the Association of Energy Engineers to individuals who can demonstrate broad, practical knowledge of energy management. It is aimed at engineers, facility and plant managers, energy consultants, commissioning and sustainability staff, and others accountable for reducing energy use and cost in commercial, institutional, and industrial facilities. The AEE Certified Energy Manager (CEM) study guide has 10 sections and about 3,034 words.

01

Codes and Standards

Codes questions test scope, not memorized numbers. ASHRAE Standard 90.1 governs energy efficiency in commercial buildings and residential buildings more than three stories above grade.

303 words, about 2 min
02

Electrical Power Systems and Motors

Real power (kW) does work, apparent power (kVA) loads conductors and transformers, and reactive power (kVAR) is the gap between them: kW = kVA x PF. Three-phase real power = 1.732 x V(line-line) x I x PF.

319 words, about 2 min
03

Maintenance and Commissioning

Reactive (run-to-failure) maintenance is cheap to administer and expensive in downtime; preventive maintenance is calendar-based; predictive (condition-based) maintenance uses vibration analysis, oil analysis, infrared thermography, and ultrasonic leak detection to intervene just before failure. Reliability-centered maintenance prioritizes tasks by failure consequence using FMEA and MTBF data.

265 words, about 1 min
04

Energy Audits and Instrumentation

ASHRAE Standard 211 defines the levels the exam expects. Level 1 is a walk-through: utility bill analysis, rough benchmarking, a list of low-cost opportunities, and no rigorous savings calculations.

302 words, about 2 min
05

CHP Systems and Renewable Energy

Combined heat and power recovers waste heat from on-site generation. Prime movers include reciprocating engines (strong electrical efficiency plus recoverable jacket and exhaust heat), gas turbines and microturbines (high-temperature exhaust usable for steam or absorption cooling), fuel cells (high electrical efficiency, low emissions), and back-pressure steam turbines.

315 words, about 2 min
06

HVAC Systems

COP = EER / 3.412, and 1 kW/ton equals COP 3.517 and EER 12.0. EER is a full-load rating, SEER is seasonal for small unitary equipment, and IEER or IPLV captures part-load behavior, which is the honest number for a chiller running most hours at 30 to 60% load.

304 words, about 2 min
07

Building Automation and Control Systems

Field DDC controllers run local sequences; supervisory controllers handle scheduling, trending, and alarms. Protocols include BACnet, Modbus, and LonWorks, with gateways translating between them.

295 words, about 1 min
08

Thermal Energy Storage Systems

Thermal energy storage decouples production from demand. Chilled water storage uses sensible heat: 1 ton-hour = 12,000 Btu, and with a 10 F usable delta-T one cubic foot of water holds about 624 Btu, so plan roughly 19 cubic feet per ton-hour plus unusable stratified volume.

325 words, about 2 min
09

Lighting Systems

Lumens measure light output, efficacy is lumens per watt, illuminance is foot-candles (1 fc = 10.76 lux), and lighting power density is W/ft2. Codes regulate LPD, not illuminance, and LPD must be computed from fixture input watts, meaning lamp watts plus ballast or driver losses, not lamp watts alone.

298 words, about 1 min
10

Energy Savings Performance Contracting and Measurement and Verification

Measurement and verification rests on a transparent, adjusted baseline. IPMVP defines four options: A (retrofit isolation with key parameters measured, others stipulated), B (retrofit isolation with all parameters measured), C (whole-building metering), and D (calibrated simulation).

308 words, about 2 min