- Ohm's Law
- The relationship among voltage, current, and resistance in a circuit, expressed as E = I × R. Knowing any two quantities lets you solve for the third.
- Series Circuit Resistance
- In a series circuit, current is common to all elements and total resistance equals the sum of the individual resistances. Total voltage divides across the elements.
- Parallel Circuit Resistance
- In a parallel circuit, voltage is common across branches and total resistance is less than the smallest branch resistance, found by summing reciprocals.
- RMS Value
- The effective value of an alternating current that produces the same heating as an equal direct current. For a sine wave it equals peak divided by the square root of two.
- Inductive Reactance
- Opposition to alternating current caused by inductance, calculated as two pi times frequency times inductance. It increases as frequency rises and causes current to lag voltage.
- Three-Phase Power
- Real power in a balanced three-phase circuit equals the square root of three times line voltage times line current times power factor.
- Dwelling Lighting Load
- The general lighting and receptacle load for a dwelling is computed at three volt-amperes per square foot of floor area before demand factors are applied.
- Small-Appliance Circuits
- Dwellings require at least two 20-ampere small-appliance branch circuits, each calculated at 1500 volt-amperes for service load purposes.
- Largest Motor Addition
- When calculating a service or feeder, the largest motor load is increased by 25 percent to account for starting current.
- Branch-Circuit Rating
- The rating of a branch circuit is determined by the ampere rating of its overcurrent protective device, not by the conductor size alone.
- Raceway Fill Percentage
- The maximum portion of a raceway interior cross section that conductors may occupy, such as 40 percent for three or more conductors in a run.
- Box Fill Calculation
- Box volume must accommodate each conductor, device, fitting, and grounding conductor using the volume allowances assigned by conductor size.
- 360-Degree Bend Rule
- No more than 360 degrees of bends, whether made in the raceway or by fittings, is permitted between pull points in a run.
- Expansion Fitting Use
- Expansion fittings accommodate movement where a raceway crosses a building expansion joint or where thermal expansion and contraction are expected.
- Conductor Ampacity
- The current a conductor can carry continuously under stated conditions, taken from ampacity tables and adjusted for ambient temperature and conductor count.
- Parallel Conductor Rules
- Conductors run in parallel must have the same length, material, size, insulation, and termination so current divides equally among them.
- Receptacle Spacing
- Along dwelling unit wall space, receptacle outlets must be placed so no point on the floor line is more than six feet from an outlet.
- Counter Receptacle Spacing
- Kitchen and similar countertop receptacles must be installed so no point along the counter is more than 24 inches from a receptacle outlet.
- Conductor Color Identification
- The grounded conductor is identified white or gray, the equipment grounding conductor green or bare, and ungrounded conductors by other approved colors.
- Standard OCPD Ratings
- Overcurrent devices are made in standard ratings such as 15, 20, 30, 40, 50, 60, 70, 80, 90, and 100 amperes, used for selection and sizing.
- GFCI Protection Purpose
- A ground-fault circuit interrupter detects small line-to-ground current imbalances and opens the circuit to protect people from electric shock.
- AFCI Protection Purpose
- An arc-fault circuit interrupter recognizes the signature of dangerous arcing and de-energizes the circuit to reduce the risk of fire.
- Equipment Grounding Conductor
- A conductor that connects non-current-carrying metal parts to the grounding system and provides a low-impedance fault path to operate overcurrent devices.
- Motor Branch Conductor Sizing
- Motor branch-circuit conductors must have an ampacity of at least 125 percent of the motor full-load current taken from the code motor tables.
- Motor Overload Protection
- Overload protection guards the motor against excessive current from overloading, while branch-circuit protection handles short circuits and ground faults.
- Motor Disconnect Location
- A motor disconnecting means must be within sight of the motor and its controller, or capable of being locked in the open position.
- Motor Full-Load Current Source
- For sizing motor conductors and protection, full-load current is read from the code motor tables rather than from the motor nameplate.
- Hazardous Location Classes
- Class I covers flammable gases and vapors, Class II covers combustible dust, and Class III covers easily ignitable fibers or flyings.
- Division 1 Versus Division 2
- Division 1 means the hazardous condition exists under normal operation; Division 2 means it exists only under abnormal or fault conditions.
- Wet Location Requirements
- Wet locations require enclosures and fittings listed for wet use, with gaskets and weatherproof construction that shed water.
- Authority Having Jurisdiction
- The organization or individual responsible for enforcing the electrical code, interpreting its provisions, and approving equipment, materials, and installations.
- Concealed Work Inspection
- Electrical work that will be concealed must be inspected and approved before walls, ceilings, or other coverings are installed over it.
- Alaska Electrician Licensing
- Alaska requires electricians to hold a state journeyman or master license, or to work as a registered apprentice under a licensed electrician's supervision.
- Electrical Contractor Administrator
- An Alaska electrical contractor must be licensed and must employ a licensed administrator who is responsible for code compliance of the contractor's work.