Ohm's Law

The fixed relationship stating that voltage equals current multiplied by resistance (E = I × R). Knowing any two values lets you calculate the third in a circuit.

Related: Power Formula (Watt's Law), Voltage Drop
Power Formula (Watt's Law)

The relationship that electrical power in watts equals voltage multiplied by current (P = E × I). Used to size circuits and determine load in amperes.

Related: Ohm's Law, Demand Factor
Voltage Drop

The loss of voltage along conductors caused by their resistance as current flows. Excessive drop reduces equipment performance and is limited by code for feeders and branch circuits.

Related: Ohm's Law, Feeder, Branch Circuit
Alternating Current (AC)

Current that periodically reverses direction, typically 60 hertz in North America. Most building wiring and motors operate on AC power.

Related: Power Factor, Three-Phase System
Power Factor

The ratio of real power to apparent power in an AC circuit, expressed between zero and one. Low power factor means more current is drawn for the same useful work.

Related: Alternating Current (AC), Motor Full-Load Current
Three-Phase System

A power distribution method using three conductors with voltages offset by 120 degrees. It supplies large motors and commercial services more efficiently than single-phase systems.

Related: Alternating Current (AC), Motor Full-Load Current
Series Circuit

A circuit where current has only one path through all components. The same current flows through each device and total resistance is the sum of individual resistances.

Related: Parallel Circuit, Ohm's Law
Parallel Circuit

A circuit where current divides among multiple paths connected across the same voltage. Total resistance is always less than the smallest individual branch resistance.

Related: Series Circuit, Branch Circuit
Branch Circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlet or outlets it serves. It supplies the actual loads in a building.

Related: Feeder, Overcurrent Device, Voltage Drop
Feeder

All circuit conductors between the service equipment, source of a separately derived system, or other supply source and the final branch-circuit overcurrent device.

Related: Branch Circuit, Service Conductors, Voltage Drop
Service Conductors

The conductors that carry power from the utility supply point to the service equipment disconnecting means. They are sized for the total calculated load of the premises.

Related: Feeder, Demand Factor, Service Disconnect
Demand Factor

The ratio of the maximum demand on a system to the total connected load. It allows feeders and services to be sized smaller than the sum of all loads.

Related: Connected Load, Service Conductors, Power Formula (Watt's Law)
Connected Load

The sum of the rated capacities of all equipment and outlets connected to a system. It is the starting point before demand factors are applied.

Related: Demand Factor, Service Conductors
Ampacity

The maximum current a conductor can carry continuously under the conditions of use without exceeding its temperature rating. It depends on conductor size, insulation, and ambient conditions.

Related: Conductor Ampacity Adjustment, Overcurrent Device, Conductor
Conductor Ampacity Adjustment

The reduction of a conductor's current-carrying capacity to account for bundling, high ambient temperature, or installation in thermal insulation. Tables and correction factors are applied.

Related: Ampacity, Raceway Fill
Conductor

A material, usually copper or aluminum, that carries electric current. Conductors are sized by cross-sectional area and identified by American Wire Gauge or kcmil.

Related: Ampacity, Insulation Rating
Insulation Rating

The maximum temperature and voltage a conductor's covering is designed to withstand, such as 60, 75, or 90 degrees Celsius. It limits the ampacity permitted for the conductor.

Related: Conductor, Ampacity
Overcurrent Device

A device such as a fuse or circuit breaker that automatically opens a circuit when current exceeds a safe level. It protects conductors and equipment from overheating.

Related: Branch Circuit, Ground-Fault Protection, Arc-Fault Circuit Interrupter
Grounding Electrode System

The set of grounding electrodes, such as rods, pipes, or concrete-encased electrodes, and their bonding jumpers that connect the electrical system to earth.

Related: Equipment Grounding Conductor, Bonding, Ground-Fault Protection
Equipment Grounding Conductor

The conductor that connects the non-current-carrying metal parts of equipment to the grounding system. It provides a low-impedance path for fault current.

Related: Grounding Electrode System, Bonding, Ground-Fault Protection
Bonding

The permanent joining of metal parts to form an electrically conductive path that ensures electrical continuity. Bonding keeps metal parts at the same potential to prevent shock.

Related: Equipment Grounding Conductor, Grounding Electrode System
Ground-Fault Protection

A system that detects current leaking to ground and opens the circuit to prevent shock or fire. It is required for certain receptacles, equipment, and services.

Related: Equipment Grounding Conductor, Overcurrent Device, Bonding
Arc-Fault Circuit Interrupter

A device that detects dangerous arcing in wiring and interrupts the circuit. It is required on many branch circuits in dwelling units to reduce fire risk.

Related: Overcurrent Device, Ground-Fault Protection
Motor Full-Load Current

The current a motor draws at its rated horsepower, voltage, and frequency under full load. It is taken from code tables rather than the motor nameplate for conductor sizing.

Related: Motor Overload Protection, Motor Disconnect, Power Factor
Motor Overload Protection

A device that protects a motor from sustained excess current that causes overheating. It is sized to the motor's nameplate current and is separate from short-circuit protection.

Related: Motor Full-Load Current, Overcurrent Device, Motor Disconnect
Motor Disconnect

A means to disconnect the motor and controller from the power source for servicing. It must be within sight of the motor and controller unless specific exceptions apply.

Related: Motor Full-Load Current, Motor Overload Protection
HVAC Equipment

Heating, ventilating, and air-conditioning units such as compressors, air handlers, and heat pumps. Their nameplates provide minimum circuit ampacity and maximum overcurrent protection values.

Related: Motor Full-Load Current, Overcurrent Device
Raceway

A channel of metal or nonmetallic material designed to hold and protect conductors, such as conduit or tubing. Raceways must be properly supported and have limited fill.

Related: Raceway Fill, Box Fill, Conduit Bending
Raceway Fill

The percentage of a raceway's cross-sectional area occupied by conductors. Limits prevent overheating and make it possible to pull conductors without damage.

Related: Raceway, Conductor Ampacity Adjustment
Box Fill

The required cubic-inch volume inside an outlet, junction, or device box to safely contain conductors, devices, and fittings. It is calculated from conductor counts and device allowances.

Related: Outlet Box, Raceway Fill
Conduit Bending

The process of shaping conduit into bends such as offsets, saddles, and 90-degree turns. Correct bending maintains a smooth raceway and keeps conductors from being damaged.

Related: Raceway
Outlet Box

A box used to contain splices, receptacles, switches, or other devices at an outlet. It must be accessible and have adequate volume for the conductors it holds.

Related: Box Fill, Receptacle, Switch
Receptacle

A contact device installed at an outlet for connecting a plug to the circuit. Its rating, grounding type, and location must match the circuit and code requirements.

Related: Outlet Box, Ground-Fault Protection, Switch
Switch

A device that opens or closes a circuit to control the flow of current to a load. Switches must be rated for the circuit voltage and current they control.

Related: Receptacle, Outlet Box
Service Disconnect

The main switch or breaker used to disconnect all power from the service equipment. It must be readily accessible and clearly marked with its rating.

Related: Service Conductors, Overcurrent Device
Hazardous Location

An area where fire or explosion hazards may exist due to flammable gases, vapors, dusts, or fibers. Equipment and wiring methods there must follow special classification rules.

Related: Classified Location Equipment, Special Occupancy
Special Occupancy

A building or space with unique hazards or uses, such as health care facilities, places of assembly, or agricultural buildings. Wiring in these areas is subject to additional requirements.

Related: Hazardous Location, Classified Location Equipment
Classified Location Equipment

Devices and materials approved for use in specific hazardous areas, marked with class, division or zone, and group. Using unapproved equipment there creates ignition risk.

Related: Hazardous Location, Special Occupancy
Lockout/Tagout

A safety procedure that isolates energy sources and applies locks and tags before work begins. It prevents accidental energization of equipment being serviced.

Related: Permit, Inspection
Permit

An official authorization to perform electrical work, issued by the local authority before work starts. It documents the scope and triggers required inspections.

Related: Inspection, Authority Having Jurisdiction, Lockout/Tagout
Inspection

The review of electrical work by an authorized official to confirm it meets code and approved plans. Work must be accessible for inspection at required stages.

Related: Permit, Authority Having Jurisdiction
Authority Having Jurisdiction

The organization or individual responsible for enforcing code requirements and approving equipment and installations. Local building officials commonly serve in this role.

Related: Inspection, Permit
Electrical Contractor License

A credential issued by the state that authorizes a business to offer and perform electrical contracting work. It requires a qualifying individual and compliance with state rules.

Related: Journeyman Electrician License, Permit
Journeyman Electrician License

A state-issued credential allowing a person to perform electrical work under an electrical contractor. It is earned through experience, examination, and continuing requirements.

Related: Electrical Contractor License, Continuing Education
Continuing Education

Required ongoing training hours that licensees complete to renew their electrical credential. It keeps practitioners current on code changes and safety practices.

Related: Journeyman Electrician License, Electrical Contractor License