AK Electrician key terms
AK Electrician · Get comfortable with the vocabulary.
- Ohm's Law
- Related: Power Formula (Watt's Law), Voltage Drop
The fixed relationship stating that voltage equals current multiplied by resistance (E = I × R). Knowing any two values lets you calculate the third in a circuit.
- Power Formula (Watt's Law)
- Related: Ohm's Law, Demand Factor
The relationship that electrical power in watts equals voltage multiplied by current (P = E × I). Used to size circuits and determine load in amperes.
- Voltage Drop
- Related: Ohm's Law, Feeder, Branch Circuit
The loss of voltage along conductors caused by their resistance as current flows. Excessive drop reduces equipment performance and is limited by code for feeders and branch circuits.
- Alternating Current (AC)
- Related: Power Factor, Three-Phase System
Current that periodically reverses direction, typically 60 hertz in North America. Most building wiring and motors operate on AC power.
- Power Factor
- Related: Alternating Current (AC), Motor Full-Load Current
The ratio of real power to apparent power in an AC circuit, expressed between zero and one. Low power factor means more current is drawn for the same useful work.
- Three-Phase System
- Related: Alternating Current (AC), Motor Full-Load Current
A power distribution method using three conductors with voltages offset by 120 degrees. It supplies large motors and commercial services more efficiently than single-phase systems.
- Series Circuit
- Related: Parallel Circuit, Ohm's Law
A circuit where current has only one path through all components. The same current flows through each device and total resistance is the sum of individual resistances.
- Parallel Circuit
- Related: Series Circuit, Branch Circuit
A circuit where current divides among multiple paths connected across the same voltage. Total resistance is always less than the smallest individual branch resistance.
- Branch Circuit
- Related: Feeder, Overcurrent Device, Voltage Drop
The circuit conductors between the final overcurrent device protecting the circuit and the outlet or outlets it serves. It supplies the actual loads in a building.
- Feeder
- Related: Branch Circuit, Service Conductors, Voltage Drop
All circuit conductors between the service equipment, source of a separately derived system, or other supply source and the final branch-circuit overcurrent device.
- Service Conductors
- Related: Feeder, Demand Factor, Service Disconnect
The conductors that carry power from the utility supply point to the service equipment disconnecting means. They are sized for the total calculated load of the premises.
- Demand Factor
- Related: Connected Load, Service Conductors, Power Formula (Watt's Law)
The ratio of the maximum demand on a system to the total connected load. It allows feeders and services to be sized smaller than the sum of all loads.
- Connected Load
- Related: Demand Factor, Service Conductors
The sum of the rated capacities of all equipment and outlets connected to a system. It is the starting point before demand factors are applied.
- Ampacity
- Related: Conductor Ampacity Adjustment, Overcurrent Device, Conductor
The maximum current a conductor can carry continuously under the conditions of use without exceeding its temperature rating. It depends on conductor size, insulation, and ambient conditions.
- Conductor Ampacity Adjustment
- Related: Ampacity, Raceway Fill
The reduction of a conductor's current-carrying capacity to account for bundling, high ambient temperature, or installation in thermal insulation. Tables and correction factors are applied.
- Conductor
- Related: Ampacity, Insulation Rating
A material, usually copper or aluminum, that carries electric current. Conductors are sized by cross-sectional area and identified by American Wire Gauge or kcmil.
- Insulation Rating
- Related: Conductor, Ampacity
The maximum temperature and voltage a conductor's covering is designed to withstand, such as 60, 75, or 90 degrees Celsius. It limits the ampacity permitted for the conductor.
- Overcurrent Device
- Related: Branch Circuit, Ground-Fault Protection, Arc-Fault Circuit Interrupter
A device such as a fuse or circuit breaker that automatically opens a circuit when current exceeds a safe level. It protects conductors and equipment from overheating.
- Grounding Electrode System
- Related: Equipment Grounding Conductor, Bonding, Ground-Fault Protection
The set of grounding electrodes, such as rods, pipes, or concrete-encased electrodes, and their bonding jumpers that connect the electrical system to earth.
- Equipment Grounding Conductor
- Related: Grounding Electrode System, Bonding, Ground-Fault Protection
The conductor that connects the non-current-carrying metal parts of equipment to the grounding system. It provides a low-impedance path for fault current.
- Bonding
- Related: Equipment Grounding Conductor, Grounding Electrode System
The permanent joining of metal parts to form an electrically conductive path that ensures electrical continuity. Bonding keeps metal parts at the same potential to prevent shock.
- Ground-Fault Protection
- Related: Equipment Grounding Conductor, Overcurrent Device, Bonding
A system that detects current leaking to ground and opens the circuit to prevent shock or fire. It is required for certain receptacles, equipment, and services.
- Arc-Fault Circuit Interrupter
- Related: Overcurrent Device, Ground-Fault Protection
A device that detects dangerous arcing in wiring and interrupts the circuit. It is required on many branch circuits in dwelling units to reduce fire risk.
- Motor Full-Load Current
- Related: Motor Overload Protection, Motor Disconnect, Power Factor
The current a motor draws at its rated horsepower, voltage, and frequency under full load. It is taken from code tables rather than the motor nameplate for conductor sizing.
- Motor Overload Protection
- Related: Motor Full-Load Current, Overcurrent Device, Motor Disconnect
A device that protects a motor from sustained excess current that causes overheating. It is sized to the motor's nameplate current and is separate from short-circuit protection.
- Motor Disconnect
- Related: Motor Full-Load Current, Motor Overload Protection
A means to disconnect the motor and controller from the power source for servicing. It must be within sight of the motor and controller unless specific exceptions apply.
- HVAC Equipment
- Related: Motor Full-Load Current, Overcurrent Device
Heating, ventilating, and air-conditioning units such as compressors, air handlers, and heat pumps. Their nameplates provide minimum circuit ampacity and maximum overcurrent protection values.
- Raceway
- Related: Raceway Fill, Box Fill, Conduit Bending
A channel of metal or nonmetallic material designed to hold and protect conductors, such as conduit or tubing. Raceways must be properly supported and have limited fill.
- Raceway Fill
- Related: Raceway, Conductor Ampacity Adjustment
The percentage of a raceway's cross-sectional area occupied by conductors. Limits prevent overheating and make it possible to pull conductors without damage.
- Box Fill
- Related: Outlet Box, Raceway Fill
The required cubic-inch volume inside an outlet, junction, or device box to safely contain conductors, devices, and fittings. It is calculated from conductor counts and device allowances.
- Conduit Bending
- Related: Raceway
The process of shaping conduit into bends such as offsets, saddles, and 90-degree turns. Correct bending maintains a smooth raceway and keeps conductors from being damaged.
- Outlet Box
- Related: Box Fill, Receptacle, Switch
A box used to contain splices, receptacles, switches, or other devices at an outlet. It must be accessible and have adequate volume for the conductors it holds.
- Receptacle
- Related: Outlet Box, Ground-Fault Protection, Switch
A contact device installed at an outlet for connecting a plug to the circuit. Its rating, grounding type, and location must match the circuit and code requirements.
- Switch
- Related: Receptacle, Outlet Box
A device that opens or closes a circuit to control the flow of current to a load. Switches must be rated for the circuit voltage and current they control.
- Service Disconnect
- Related: Service Conductors, Overcurrent Device
The main switch or breaker used to disconnect all power from the service equipment. It must be readily accessible and clearly marked with its rating.
- Hazardous Location
- Related: Classified Location Equipment, Special Occupancy
An area where fire or explosion hazards may exist due to flammable gases, vapors, dusts, or fibers. Equipment and wiring methods there must follow special classification rules.
- Special Occupancy
- Related: Hazardous Location, Classified Location Equipment
A building or space with unique hazards or uses, such as health care facilities, places of assembly, or agricultural buildings. Wiring in these areas is subject to additional requirements.
- Classified Location Equipment
- Related: Hazardous Location, Special Occupancy
Devices and materials approved for use in specific hazardous areas, marked with class, division or zone, and group. Using unapproved equipment there creates ignition risk.
- Lockout/Tagout
- Related: Permit, Inspection
A safety procedure that isolates energy sources and applies locks and tags before work begins. It prevents accidental energization of equipment being serviced.
- Permit
- Related: Inspection, Authority Having Jurisdiction, Lockout/Tagout
An official authorization to perform electrical work, issued by the local authority before work starts. It documents the scope and triggers required inspections.
- Inspection
- Related: Permit, Authority Having Jurisdiction
The review of electrical work by an authorized official to confirm it meets code and approved plans. Work must be accessible for inspection at required stages.
- Authority Having Jurisdiction
- Related: Inspection, Permit
The organization or individual responsible for enforcing code requirements and approving equipment and installations. Local building officials commonly serve in this role.
- Electrical Contractor License
- Related: Journeyman Electrician License, Permit
A credential issued by the state that authorizes a business to offer and perform electrical contracting work. It requires a qualifying individual and compliance with state rules.
- Journeyman Electrician License
- Related: Electrical Contractor License, Continuing Education
A state-issued credential allowing a person to perform electrical work under an electrical contractor. It is earned through experience, examination, and continuing requirements.
- Continuing Education
- Related: Journeyman Electrician License, Electrical Contractor License
Required ongoing training hours that licensees complete to renew their electrical credential. It keeps practitioners current on code changes and safety practices.