AK HVAC · Get comfortable with the vocabulary.

Manual J load calculation

A room-by-room method of estimating how much heat a building loses in winter and gains in summer, used to size heating and cooling equipment correctly instead of guessing from square footage.

Related: Design temperature, Sensible heat ratio, Degree day
Design temperature

The outdoor winter and summer temperatures a system is sized to handle, chosen so equipment meets demand on all but the most extreme days. Alaska sizing uses very low winter values.

Related: Manual J load calculation, Degree day, Heating degree day
Heating degree day

A measure of how cold a climate is over a season, calculated from the difference between a 65 degrees F reference and the average daily outdoor temperature. Higher values mean more heating energy needed.

Related: Design temperature, Degree day, AFUE
Degree day

A unit expressing the gap between a base temperature and the average outdoor temperature for one day, used to estimate seasonal energy use for heating or cooling.

Related: Heating degree day, Design temperature
Sensible heat ratio

The portion of total cooling load that changes air temperature, as opposed to moisture removal. A low ratio means much of the load is latent, which matters in humid or tightly built spaces.

Related: Latent heat, Manual J load calculation, Evaporator
Latent heat

Heat energy absorbed or released when moisture changes state, such as water evaporating or vapor condensing, without changing temperature. It drives dehumidification and humidification loads.

Related: Sensible heat ratio, Evaporator, Enthalpy
Enthalpy

The total heat content of air, combining its sensible temperature and the latent energy of the moisture it carries. Technicians compare indoor and outdoor enthalpy to judge ventilation and economizer decisions.

Related: Latent heat, Psychrometric chart
Psychrometric chart

A graph showing relationships among air temperature, humidity, moisture content, and heat content. It is used to plot air conditions and analyze heating, cooling, and humidification processes.

Related: Enthalpy, Relative humidity, Dew point
Relative humidity

The percentage of moisture air holds compared with the maximum it could hold at that temperature. Warmer air can hold more, so relative humidity changes when air is heated without adding moisture.

Related: Dew point, Psychrometric chart, Humidifier
Dew point

The temperature at which air becomes saturated and moisture begins condensing on surfaces. Air cooled below its dew point forms condensate, which is why evaporator coils and cold pipes drip.

Related: Relative humidity, Condensate drain, Vapor barrier
AFUE

Annual fuel utilization efficiency, a rating of how much fuel energy a furnace or boiler converts to useful heat over a heating season. Higher percentages mean less fuel wasted up the flue.

Related: Condensing furnace, Combustion air, Heating degree day
Condensing furnace

A high-efficiency gas or oil furnace that cools flue gases enough to condense water vapor and recover latent heat, reaching efficiency above roughly 90 percent. It requires a drain for condensate.

Related: AFUE, Heat exchanger, Condensate drain
Heat exchanger

The metal component that separates hot combustion gases from the air being delivered to the building, transferring heat without mixing the two streams. Cracks can leak carbon monoxide into supply air.

Related: Combustion air, Carbon monoxide, Cracked heat exchanger
Cracked heat exchanger

A failure in the metal separating flue gases from supply air, allowing carbon monoxide and other combustion products into the occupied space. It is a serious safety hazard requiring shutdown and replacement.

Related: Heat exchanger, Carbon monoxide, Combustion air
Combustion air

The air supplied to a burner to support burning of fuel. In tight Alaska homes it must be piped or ducted from outdoors so appliances burn cleanly and do not backdraft.

Related: Backdrafting, Carbon monoxide, Heat exchanger
Backdrafting

Reversal of normal vent flow that pulls combustion products into the building instead of up the chimney, often caused by depressurization, exhaust fans, or blocked flues. It creates carbon monoxide risk.

Related: Combustion air, Carbon monoxide, Depressurization
Carbon monoxide

A colorless, odorless gas produced by incomplete combustion that binds to blood and can be fatal. Testing and proper venting, combustion air, and CO alarms are required safeguards.

Related: Backdrafting, Cracked heat exchanger, Combustion air
Hydronic system

A heating system that moves heat with water or a water-glycol mixture through pipes to terminal units such as radiators, baseboard, or radiant floors, rather than with forced air.

Related: Circulator pump, Expansion tank, Glycol
Circulator pump

A pump that moves heated water through a hydronic loop, overcoming pipe and fitting friction. Correct sizing and balance prevent noisy flow, cold zones, and short cycling.

Related: Hydronic system, Expansion tank, Balancing valve
Expansion tank

A tank that absorbs the increased volume of water as it heats in a closed hydronic system, limiting pressure rise. It contains a diaphragm or air charge that maintains system pressure.

Related: Hydronic system, Circulator pump, Relief valve
Glycol

An antifreeze additive mixed with water in hydronic or solar loops to prevent freezing in cold spaces or during outages. Concentration affects heat transfer and pump sizing.

Related: Hydronic system, Circulator pump, Freeze stat
Heat pump

Equipment that moves heat from one place to another using a refrigeration cycle, providing heating by extracting outdoor heat and cooling by reversing the flow. Cold-climate models operate at very low outdoor temperatures.

Related: Coefficient of performance, Defrost cycle, Reversing valve
Coefficient of performance

The ratio of heat delivered by a heat pump to the energy it consumes, expressed as a number such as 3.0. Higher values mean more heat per unit of electricity and vary with outdoor temperature.

Related: Heat pump, Defrost cycle, AFUE
Defrost cycle

A timed or demand-initiated mode in which a heat pump temporarily reverses or stops heating to melt frost from the outdoor coil. It prevents capacity loss and ice buildup in cold weather.

Related: Heat pump, Reversing valve, Coefficient of performance
Reversing valve

A four-way valve in a heat pump that changes refrigerant flow direction so the indoor coil becomes the evaporator in cooling or the condenser in heating.

Related: Heat pump, Defrost cycle, Evaporator
Evaporator

The coil where refrigerant absorbs heat and boils, cooling the air or water passing over it. It operates at low pressure and below the dew point, so it also collects condensate.

Related: Condenser, Condensate drain, Superheat
Condenser

The coil where refrigerant releases heat and condenses from vapor to liquid, rejecting heat outdoors in cooling or indoors in heating. It operates at higher pressure and temperature.

Related: Evaporator, Subcooling, Heat pump
Superheat

The number of degrees refrigerant vapor is above its saturation temperature at a given pressure. Measuring it at the evaporator outlet verifies proper charge and expansion valve operation.

Related: Subcooling, Evaporator, Thermostatic expansion valve
Subcooling

The number of degrees liquid refrigerant is below its saturation temperature at a given pressure. Measuring it at the condenser outlet helps confirm charge and metering device performance.

Related: Superheat, Condenser, Thermostatic expansion valve
Thermostatic expansion valve

A metering device that regulates refrigerant flow into the evaporator by responding to superheat at the coil outlet, keeping the coil properly fed across changing loads.

Related: Superheat, Evaporator, Subcooling
Condensate drain

The piping that carries water removed from air by a cooling coil to a safe disposal point. It needs proper slope, trapping, and freeze protection so it does not overflow or back up.

Related: Evaporator, Dew point, Condensing furnace
Duct static pressure

The pressure exerted by the air stream against duct walls, measured to evaluate fan performance and airflow. High static pressure signals restriction and reduced delivered airflow.

Related: External static pressure, Airflow measurement, Duct leakage
External static pressure

The resistance the duct system and components impose on the blower, measured at the equipment outlet and inlet. It is compared with the fan rating to confirm adequate airflow.

Related: Duct static pressure, Airflow measurement, Balancing damper
Duct leakage

Air escaping from joints, seams, and penetrations in ductwork, wasting energy and reducing delivered airflow. Sealing and testing are especially important when ducts run through cold spaces.

Related: Duct static pressure, Vapor barrier, Duct insulation
Duct insulation

Material wrapped around or lining ducts to limit heat loss or gain and control surface condensation. In cold climates, placement of the vapor barrier matters to prevent trapped moisture.

Related: Vapor barrier, Duct leakage, Condensate drain
Vapor barrier

A low-permeability material that limits moisture movement through building assemblies. Correct placement keeps warm moist air from reaching cold surfaces where it condenses and causes damage.

Related: Duct insulation, Dew point, Infiltration
Infiltration

Unintentional air entering a building through cracks, gaps, and penetrations. It adds heating load and can cause drafts and moisture problems in cold climates.

Related: Vapor barrier, Depressurization, Makeup air
Depressurization

A condition in which indoor pressure falls below outdoor pressure, often from exhaust fans or duct leakage, drawing outdoor air in and potentially causing appliance backdrafting.

Related: Backdrafting, Makeup air, Infiltration
Makeup air

Outdoor air supplied to replace air exhausted by fans, hoods, or other exhaust devices, keeping building pressure balanced and supporting combustion and ventilation needs.

Related: Depressurization, Infiltration, Combustion air
Balancing damper

An adjustable plate inside ductwork used to regulate airflow to individual branches so each space receives its design share of air during commissioning.

Related: External static pressure, Airflow measurement, Duct static pressure
Airflow measurement

Determining the volume of air moving through a duct or terminal, commonly with a manometer, flow hood, or anemometer, to verify the system delivers design airflow.

Related: Balancing damper, Duct static pressure, External static pressure
Freeze stat

A temperature-sensing safety control that stops a fan or burner and often closes a damper when air or water temperatures drop near freezing, protecting coils and piping from frost damage.

Related: Glycol, Low-voltage thermostat, Relief valve
Low-voltage thermostat

A control device operating typically at 24 volts that switches heating and cooling equipment based on space temperature, often with fan, staging, and setback functions.

Related: Freeze stat, Reversing valve, Circulator pump
Relief valve

A safety device on boilers, tanks, or piping that opens at a set pressure to release excess pressure and prevent rupture or explosion. It must be sized and piped to a safe discharge.

Related: Expansion tank, Hydronic system, Freeze stat
Lockout/tagout

A safety procedure that isolates energy sources and applies locks and tags so equipment cannot be re-energized while a technician services it. It prevents shock, burns, and unexpected startup.

Related: Personal protective equipment, Multimeter, Refrigerant recovery
Personal protective equipment

Gear such as gloves, eye protection, respirators, and insulated footwear worn to reduce injury risk from chemicals, sharp edges, electricity, and cold. Selection follows the task hazard.

Related: Lockout/tagout, Refrigerant recovery, Multimeter
Refrigerant recovery

The process of removing refrigerant from a system into a recovery cylinder rather than venting it to the atmosphere, as required by environmental regulations. Recovery equipment and cylinders must be rated for the refrigerant.

Related: Refrigerant recovery cylinder, Section 608 certification, Superheat
Refrigerant recovery cylinder

A DOT-approved, color-coded pressure vessel used to store recovered refrigerant. It must not be overfilled and should be labeled with the refrigerant type and quantity.

Related: Refrigerant recovery, Section 608 certification, Superheat
Section 608 certification

A required EPA credential for technicians who service or dispose of equipment containing regulated refrigerants, demonstrating knowledge of safe handling, recovery, and environmental rules.

Related: Refrigerant recovery, Refrigerant recovery cylinder, Lockout/tagout
Multimeter

A test instrument that measures voltage, current, and resistance to troubleshoot electrical circuits and controls. Safe use requires correct range selection and category-rated probes.

Related: Lockout/tagout, Low-voltage thermostat, Personal protective equipment
Mechanical permit

An official authorization from a local building authority required before installing or altering heating, ventilation, or refrigeration systems, allowing inspection of the work for code compliance.

Related: Mechanical code, Continuing education, Contractor license
Mechanical code

The adopted regulations governing installation, alteration, and inspection of heating, ventilating, and refrigeration systems, including clearances, venting, combustion air, and safety controls.

Related: Mechanical permit, Contractor license, Relief valve
Contractor license

A credential issued by the state that authorizes a business to offer and perform contracting work for compensation. Operating without one can bring fines and contract problems.

Related: Mechanical permit, Continuing education, Section 608 certification
Continuing education

Required coursework that license holders complete during each renewal period to keep their credentials current and stay informed about code and safety changes.

Related: Contractor license, Mechanical code, Mechanical permit
Lien

A legal claim against property for unpaid work or materials. Filing deadlines and notice requirements are strict, so contractors must document and follow statutory procedures carefully.

Related: Contractor license, Mechanical permit, Change order
Change order

A written modification to the scope, price, or schedule of a contract signed by both parties. It protects the contractor from doing extra work without documented compensation.

Related: Lien, Contractor license, Mechanical permit
Humidifier

A device that adds moisture to indoor air, often needed in cold climates where heating dries the space. Proper control prevents condensation and mold on cold surfaces.

Related: Relative humidity, Dew point, Vapor barrier