Retainage
A percentage, commonly 5 to 10 percent, withheld from each progress payment by the owner and released according to contract terms at substantial completion or final acceptance.
Critical Path
The longest continuous sequence of dependent activities through a project schedule network; its total float is zero and any delay on it delays project completion.
Bid Bond
A surety instrument, usually 5 to 10 percent of the bid amount, guaranteeing the bidder will enter the contract if awarded and furnish the required performance and payment bonds.
Liquidated Damages
A fixed per-day monetary amount stated in the contract that the contractor pays the owner for delay beyond the contract completion date, without proving actual loss.
Type C Soil
The least stable OSHA soil classification, with a maximum allowable excavation slope of 1.5 horizontal to 1 vertical and no benching permitted.
Competent Person
An individual capable of identifying existing and predictable hazards and authorized to take prompt corrective action, required for daily excavation inspections before workers enter.
Frost Depth
The maximum depth to which soil freezes in a given region; exterior footings must bear below this line to prevent frost heave.
Standard Proctor
ASTM D698 laboratory test that determines the maximum dry density and optimum moisture content of soil, used as the reference for field compaction.
Water-Cement Ratio
The ratio of water to cementitious material by weight in a concrete mix; lower values increase strength and reduce permeability.
Slump Test
ASTM C143 field test measuring concrete consistency by the vertical settlement of a molded cone, indicating workability and water content.
Mortar Type N
A medium-strength masonry mortar commonly used for above-grade, non-load-bearing or moderate-load walls; lower strength than Type M or S.
28-Day Strength
The compressive strength f'c that concrete is specified to achieve at 28 days of curing, the standard basis for structural design and acceptance.
A992 Steel
A common structural steel specification for wide-flange shapes with a minimum yield strength of 50 ksi and specified tensile properties.
Shear Stud
A welded steel headed stud that transfers horizontal shear between a steel beam and concrete slab, creating composite action.
High-Strength Bolt
An A325 or A490 bolt installed to a specified tension used in structural steel connections, either pretensioned or slip-critical.
AISC Standard Practice
The document establishing accepted tolerances, erection procedures, and responsibilities for structural steel fabrication and installation in the United States.
Vapor Retarder
A material of low permeance installed on the warm side of insulation to limit moisture vapor diffusion into building assemblies and prevent condensation.
Low-Slope Roof
A roof with a slope of less than 3:12, typically covered with a membrane such as TPO, EPDM, or modified bitumen.
Counterflashing
The metal flashing embedded in or attached to a wall or reglet that overlaps base flashing to shed water at a roof-to-wall junction.
Weather Barrier
A sheet or membrane applied over sheathing behind cladding to resist air and water infiltration while allowing vapor to escape.
Fire Door Rating
The time in minutes or hours a door assembly resists fire, determined by the rating of the wall opening it protects.
Tempered Glass
Safety glazing heat-treated to fracture into small granules; required in hazardous locations such as doors, sidelights, and glazing near floors.
Drywall Level 5
The highest gypsum board finish, with a skim coat over the entire surface, used where glossy paint or critical lighting will show imperfections.
Panic Hardware
Latching hardware that releases with a single motion in the direction of egress, required on egress doors serving large occupant loads.
Clash Detection
A BIM coordination process that identifies geometric conflicts among structural, mechanical, electrical, and plumbing models before fabrication and installation.
Plumbing Pressure Test
A hydrostatic or air test of piping systems performed before concealment to verify joints are leak-free at the specified test pressure.
Duct Hanger Spacing
The maximum interval between supports for HVAC ductwork, specified by SMACNA and the project documents to prevent sag and vibration.
Commissioning
A systematic process of verifying that building systems and assemblies perform according to the owner's requirements and design intent.
Fall Protection Threshold
OSHA requires fall protection for construction workers exposed to falls of 6 feet or more, or 10 feet when working on scaffolds.
Guardrail Height
The top edge of a guardrail must be 42 inches above the walking surface, plus or minus 3 inches, with a midrail installed.
Occupancy Classification
The IBC category assigned to a building based on its use, which determines egress, fire separation, and construction requirements.
Plan Scale
The ratio relating drawing dimensions to actual dimensions, such as 1/4 inch equals 1 foot, used to measure distances on plans.