AL Plumber study materials
AL Plumber study resources

AL Plumber cheat sheet

AL Plumber · Keep the key ideas within reach.

Quick reference

General Regulations, Definitions, and Code Administration

  • A plumbing permit is required before new installation, alteration, replacement, or repair unless the code or authority having jurisdiction exempts the work.

  • Approved materials and fixtures must be installed according to their listing; used materials require approval before reuse.

  • Work must remain accessible for inspection, and concealment before inspection requires approval.

  • The code official has authority to issue stop-work orders, require tests, and approve or reject installations.

  • A fixture unit is a measure of the load-producing effect of a fixture on the drainage system.

  • Developed length is measured along the pipe centerline including fittings and changes in direction.

  • An air gap is the unobstructed vertical distance between a supply outlet and the flood-level rim.

  • A cross-connection is any connection between potable water and a nonpotable source.

Quick reference

Plumbing Mathematics, Plan Reading, and Isometric Drawings

  • 1 psi equals 2.31 feet of water column; pressure in psi = head in feet × 0.433.

  • Drainage slope as a percent = inches per foot ÷ 12 × 100; 1/4 inch per foot is about 2.08%.

  • For a 45-degree offset, travel = offset × 1.414.

  • Decimal feet = inches ÷ 12; 6 inches = 0.5 foot.

  • Volume of a cylinder = π × radius² × length; 1 gallon = 231 cubic inches.

  • On an isometric drawing, vertical lines are vertical and horizontal lines are drawn at 30 degrees from horizontal.

  • Scale 1/4 inch = 1 foot means 1/4 inch on the drawing represents 12 inches actual.

  • Total drainage fixture units are added arithmetically and then converted with code tables for pipe sizing.

Quick reference

Plumbing Fixtures, Fixture Fittings, and Appliances

  • Standard drainage fixture units: water closet 3, lavatory 1, bathtub 2, shower 2, kitchen sink 2.

  • Water closet clearance: at least 15 inches from centerline to sidewall and 21 inches clear in front.

  • Federal maximum showerhead flow is 2.5 gpm at 80 psi.

  • Water closet maximum flush volume is 1.6 gallons per flush; urinal maximum is 1.0 gallon per flush.

  • Floor drains subject to trap evaporation require a trap primer.

  • Food-handling equipment and sterilizers use indirect waste with an air gap or air break.

  • Accessible lavatory rim height is generally 34 inches maximum above the finished floor.

  • Fixture supply stops are required at each fixture except where the code permits otherwise.

Quick reference

Water Supply and Distribution Systems

  • Minimum flowing pressure: 8 psi at flush tanks and general fixtures; 15 psi at flushometer valves.

  • A pressure-reducing valve is required where static pressure exceeds 80 psi.

  • Closed potable water systems with a water heater require thermal expansion control.

  • Water hammer arrestors are installed near quick-closing valves to absorb pressure surges.

  • Water distribution pipe sizing uses fixture units, developed length, and allowable pressure loss.

  • Hot and cold water pipe must be protected from freezing; buried service is installed below frost depth.

  • Potable water lines must be separated from nonpotable lines and cannot be directly connected to a nonpotable source.

  • A water service pipe cannot be installed in the same trench as a sewer unless separation and materials meet code.

Quick reference

Sanitary Drainage Systems and Drainage Design

  • Slope: 2.5 inches and smaller = 1/4 inch per foot; 3 to 6 inches = 1/8 inch per foot; 8 inches and larger = 1/16 inch per foot.

  • Drainage pipe size must not decrease in the direction of flow.

  • Cleanouts are required at the base of each stack, every 100 feet of horizontal drain, and at changes greater than 45 degrees.

  • A building drain extends from inside the building to 30 inches outside the building wall.

  • A building sewer begins at the building drain and runs to the public sewer or private disposal system.

  • Backwater valves are required for fixtures below the street or sewer level where backup is possible.

  • Trap arms must be vented within the code-listed distance for the pipe size.

  • Horizontal drainage pipe receiving a vertical stack requires approved fittings at the transition.

Quick reference

Vents and Venting Systems

  • Every fixture trap must be vented unless the code lists a specific exception.

  • Vent pipe must rise at least 6 inches above the fixture flood-level rim before any horizontal offset.

  • Vent terminals must extend at least 6 inches above the roof and be located away from windows, doors, and air intakes.

  • Vent pipe cannot be smaller than 1.25 inches and must meet the code size table.

  • A wet vent serves as both a drain and a vent only for code-listed fixture combinations.

  • An air admittance valve requires accessibility and must be listed for the application.

  • A vent stack and stack vent connect the drainage stack to the vent system.

  • A circuit vent vents a row of fixtures through a common vent line.

Quick reference

Traps, Interceptors, and Special Wastes

  • Trap seal depth must be at least 2 inches and not more than 4 inches.

  • Each fixture requires an individual trap except where the code permits common or combination traps.

  • S-traps, crown vents, and double trapping are prohibited.

  • Grease interceptors are required for commercial kitchen waste and must be sized per code.

  • Sand and oil interceptors are required for garages and similar facilities where these wastes are discharged.

  • Indirect waste receptors receive waste through an air gap or air break.

  • Trap primers maintain trap seals for floor drains subject to evaporation.

  • Interceptors require accessible cleanouts for maintenance.

Quick reference

Water Heaters and Temperature Control

  • A temperature and pressure relief valve is required on each water heater.

  • The T&P relief valve opens at about 210 degrees Fahrenheit or 150 psi and discharges by gravity, full size, without a valve.

  • The relief discharge must terminate at least 6 inches above the floor or to an approved drain.

  • A closed potable water system with a water heater requires a thermal expansion tank.

  • A drain pan is required where leakage could cause damage; its drain goes to an indirect waste.

  • Gas water heaters require combustion air and proper flue venting.

  • The relief valve opening must not be capped, plugged, or reduced.

  • Water heater seismic strapping is required where the code or local jurisdiction mandates it.

Quick reference

Backflow Prevention and Cross-Connection Control

  • An air gap provides the highest protection against backflow because it physically separates potable water from the hazard.

  • A reduced pressure zone assembly is used for high-hazard connections and must be tested annually.

  • A double check valve assembly is used for low-hazard connections and is testable.

  • A hose bib vacuum breaker protects a threaded hose connection from backsiphonage.

  • Backflow can occur by backsiphonage or by backpressure.

  • Irrigation systems, boiler feed lines, and chemical lines require approved backflow protection.

  • A cross-connection control program requires testing, records, and repair of testable assemblies.

  • No direct connection is permitted between potable water and a nonpotable source.

Quick reference

Gas Piping and Gas-Fitting Systems

  • Gas pipe sizing uses appliance Btu/hr input, pipe length, gas specific gravity, and allowable pressure drop.

  • Natural gas heating value is commonly taken as about 1,000 Btu per cubic foot; LP gas is about 2,500 Btu per cubic foot.

  • A sediment trap or drip leg is required at each appliance connection.

  • A shutoff valve must be installed on the gas supply to each appliance in an accessible location.

  • Gas piping must be pressure tested with air or inert gas before service; test pressure and time depend on code and system pressure.

  • Gas connectors are limited in length and cannot pass through walls, floors, or ceilings.

  • CSST gas piping must be bonded as required by the manufacturer and code.

  • Gas appliances require combustion air and approved venting.