32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Plumbing permit
A permit is required before beginning new plumbing installation, alteration, replacement, or repair unless the work is specifically exempted by the code or the authority having jurisdiction.
Fixture unit
A fixture unit is a measure of the load-producing effect of a plumbing fixture on the drainage system; fixture unit values are used to size drainage and vent piping.
Air gap
An air gap is the unobstructed vertical distance through free atmosphere between a potable water supply outlet and the flood-level rim of a fixture or receptacle.
Developed length
Developed length is the measured length along the centerline of a pipe including fittings and changes in direction, used for pipe sizing and pressure-loss calculations.
Water column pressure
One psi equals about 2.31 feet of water column, so static pressure in psi can be calculated by multiplying head in feet by 0.433.
45-degree offset travel
For a 45-degree offset, the travel or diagonal length equals the offset multiplied by 1.414, because the secant of 45 degrees is approximately 1.414.
Scale reading
On a drawing with a scale of 1/4 inch equals 1 foot, a measured line of 1/4 inch represents 1 actual foot; multiply drawing length by the scale factor.
Water closet fixture units
A water closet typically carries 3 drainage fixture units, while a lavatory carries 1 and a bathtub or shower carries 2 in standard plumbing fixture-unit tables.
Toilet clearance
A water closet must have at least 15 inches from its centerline to a sidewall and at least 21 inches of clear space in front of the bowl.
Showerhead flow limit
A showerhead is limited to a maximum flow rate of 2.5 gallons per minute at 80 psi under federal efficiency standards for residential fixtures.
Residual pressure
Fixture supply pressure must remain at least 8 psi for flush tanks and general fixtures and at least 15 psi for flushometer valves under flowing conditions.
Pressure-reducing valve
A pressure-reducing valve is required when static water pressure exceeds 80 psi, and a thermal expansion control device is also needed on a closed system.
Water hammer arrestor
A water hammer arrestor is installed near quick-closing valves to absorb pressure surges caused by sudden stoppage of water flow in piping.
Drain slope
Sanitary drainage pipe 2.5 inches and smaller slopes at 1/4 inch per foot; 3-inch through 6-inch pipe slopes at 1/8 inch per foot; larger pipe slopes at 1/16 inch per foot.
Cleanout interval
Cleanouts are required at the base of each stack, at each horizontal drainage pipe run of 100 feet, and at changes in direction greater than 45 degrees.
Backwater valve
A backwater valve is installed on drainage fixtures below the street or sewer level to prevent sewage from reversing into the building during a sewer backup.
Building drain
A building drain is the lowest piping of a drainage system that receives waste from inside the building and extends to a point 30 inches outside the building wall.
Vent terminal height
A vent stack must extend at least 6 inches above the roof, and vent terminals must be located away from windows, doors, and air intakes as required by code.
Wet vent
A wet vent is a vent that also serves as a drain for fixtures, and it is permitted only for specific fixture combinations and sizes listed in the plumbing code.
Air admittance valve
An air admittance valve admits air into a drainage system to protect trap seals and must be installed in an accessible location with at least one valve per vent system.
Trap seal depth
A fixture trap must maintain a water seal of at least 2 inches and not more than 4 inches to prevent sewer gas from entering the building.
Grease interceptor
A grease interceptor is required for commercial kitchen waste lines to separate fats, oils, and grease before the waste enters the sanitary drainage system.
Indirect waste
An indirect waste receptor receives liquid waste through an air gap or air break so the waste cannot back up into a fixture or contaminate potable water.
T&P relief valve
A temperature and pressure relief valve on a water heater is set to open at about 210 degrees Fahrenheit or 150 psi and discharges by gravity to a safe location.
Thermal expansion tank
A thermal expansion tank is required on a closed potable water system to absorb the increased volume created when water is heated in the water heater.
Water heater drain pan
A water heater drain pan is required where leakage could cause damage; the pan drain must discharge by gravity to an approved indirect waste receptor.
Reduced pressure zone
A reduced pressure zone backflow assembly provides high-hazard protection by maintaining a pressure differential between the potable supply and the hazard; it must be tested annually.
Air gap backflow
An air gap provides the highest degree of backflow protection because it creates a physical separation between the potable water outlet and the flood-level rim.
Hose bib vacuum breaker
A hose bib vacuum breaker is a non-testable device installed on a threaded hose connection to prevent backsiphonage of contaminated water into the potable supply.
Sediment trap
A sediment trap or drip leg is installed at the appliance connection to collect dirt and debris before it can enter the gas controls or burner.
Natural gas heating value
Natural gas is commonly assumed to have a heating value near 1,000 Btu per cubic foot, while liquefied petroleum gas is near 2,500 Btu per cubic foot.
Gas piping test
Gas piping must be pressure tested with air or inert gas before being placed in service; the test pressure and duration depend on the system pressure and code requirements.