CO2 corrosion mechanism
Dissolved CO2 forms carbonic acid, which cathodically reduces at the steel surface, driving iron dissolution; rate depends on pH, temperature, pCO2, and protective FeCO3 scale.
H2S partial pressure threshold
A partial pressure above 0.05 psi generally defines sour service under NACE MR0175/ISO 15156, requiring materials qualified for sulfide stress cracking resistance.
Galvanic corrosion condition
Two dissimilar metals in electrolytic contact create a potential difference; the more active metal becomes the anode and corrodes faster, especially with a large cathode-to-anode area ratio.
Erosion-corrosion definition
Mechanical removal of protective films or metal by flowing fluid, sand, or droplets accelerates corrosion; severity depends on velocity, flow regime, and solids content.
MIC mechanism
Sulfate-reducing and acid-producing bacteria in biofilms generate H2S or organic acids, creating localized pitting under deposits; sessile populations are the key indicator.
Underdeposit corrosion
Differential aeration under scale, sand, or debris creates an occluded anode; the small anodic area relative to the external cathode drives deep, compact pits.
Temperature effect on corrosion
Corrosion rate typically rises with temperature to a maximum near 60-80 C for CO2 systems, then falls as protective FeCO3 scale becomes stable.
pCO2 screening threshold
A CO2 partial pressure above about 7 psi is commonly used as a screening trigger for sweet corrosion evaluation in carbon steel systems.
Wall shear stress effect
High shear removes protective films and increases mass transfer, raising corrosion rate; low-velocity stratified flow promotes water dropout and underdeposit attack.
Chloride effect on scale
Chloride ions reduce FeCO3 stability and promote pitting; higher chloride content generally increases corrosion risk in CO2 systems.
H2S IDLH value
The immediately dangerous to life or health concentration for H2S is 100 ppm; odor fatigue occurs above this level, so monitors and escape sets are required.
Confined space entry
Entry into pits, sumps, and tanks requires atmospheric testing for O2, H2S, and flammables before and during entry, plus standby personnel and rescue plans.
Sour service material requirement
Materials in H2S service must comply with NACE MR0175/ISO 15156 to resist sulfide stress cracking and hydrogen-induced cracking.
Fitness-for-service assessment
Methods such as ASME B31G and API 579 evaluate remaining strength of corroded pipe to set safe operating limits before continued service.
Coupon weight loss
Retrievable coupons exposed for a known period give average general corrosion rate by mass loss; pit depth and density must be measured separately for localized attack.
ER probe principle
Electrical resistance probes measure metal loss in real time from resistance change; they track general trends but are less sensitive to localized pitting than coupons.
LPR measurement
Linear polarization resistance measures instantaneous corrosion rate from the slope of current versus potential; it requires a conductive aqueous electrolyte and is affected by films.
Iron count interpretation
Iron concentration in produced water correlates with corrosion rate; spikes indicate increased corrosion or solids carryover and should be trended with production data.
Pit morphology clues
Deep compact pits suggest MIC or underdeposit corrosion; elongated pits aligned with flow suggest erosion-corrosion; uniform thinning suggests general corrosion.
Inhibitor partitioning
Film-forming inhibitors must partition into the water phase to reach the steel surface; performance depends on water cut, shear, and persistence.
Water injection treatment
Deaeration, oxygen scavengers, and biocide programs control oxygen corrosion and MIC in injection systems; SRB control may use nitrate or nitrite treatments.
CRA selection factors
Corrosion-resistant alloys such as 13Cr, duplex, and nickel alloys reduce mitigation burden but must be qualified for chloride SCC and sour service conditions.
Internal coating function
Coatings and linings isolate steel from electrolyte; holiday and defect inspection is essential because failures localize attack at coating breaks.
pH stabilization
Raising pH promotes protective FeCO3 scale and reduces CO2 corrosion rate; requires water chemistry control and monitoring to avoid scaling or cracking risks.
Non-intrusive ultrasonic monitoring
Permanently or temporarily mounted ultrasonic sensors track wall thickness without hot work or shutdown, supporting periodic or continuous corrosion monitoring.
Smart pig inspection
Instrumented inline inspection pigs map metal loss along the pipeline; they require piggable geometry and provide high-resolution wall-thickness data.
Risk-based inspection
RBI allocates inspection resources by likelihood and consequence of failure, aligning monitoring and inspection frequency with risk ranking.
Failure analysis sequence
Collect background, inspect the failure site, characterize morphology, analyze deposits and fluids, then test hypotheses to distinguish mechanism from contributing factors.
Deposit analysis methods
XRD, SEM, and EDS identify corrosion products such as FeCO3, FeS, and Fe3O4, indicating scale protectiveness and corrosion mechanism.
Program KPI examples
Key performance indicators include corrosion rate targets, inhibitor availability, inspection coverage, and corrective action closure rates for program effectiveness.
Management of change
MOC ensures process, material, or chemical changes trigger re-evaluation of corrosion risk, mitigation, and inspection plans before implementation.
Record retention requirement
Corrosion control records must be retained per regulatory requirements and long enough to support audits and failure investigations; retention periods vary by jurisdiction.