AMPP ICS study materials
AMPP ICS study resources

AMPP ICS key terms

AMPP ICS · Get comfortable with the vocabulary.

Sweet corrosion (CO2 corrosion)

Metal loss driven by dissolved carbon dioxide forming carbonic acid in produced water. It often produces smooth, mesa-shaped, or pitted attack and depends strongly on partial pressure, pH, temperature, and flow.

Related: Partial pressure of CO2, Sour corrosion, Flow regime
Sour corrosion (H2S corrosion)

Corrosion caused by dissolved hydrogen sulfide in produced fluids. It can form iron sulfide films that sometimes slow attack, and it introduces sulfide stress cracking and hydrogen-induced cracking hazards in susceptible steels.

Related: Sulfide stress cracking, Hydrogen-induced cracking, Sweet corrosion (CO2 corrosion)
Microbially influenced corrosion (MIC)

Deterioration accelerated by the metabolic activity of microorganisms such as sulfate-reducing bacteria, often appearing as localized pitting, black deposits, and sulfide odors under stagnant or low-flow conditions.

Related: Sulfate-reducing bacteria, Sessile bacteria, Biocide treatment
Sulfate-reducing bacteria (SRB)

Anaerobic microorganisms that reduce sulfate to sulfide, producing corrosive sulfide species and promoting pitting and under-deposit attack in oxygen-free, often stagnant, water environments.

Related: Microbially influenced corrosion (MIC), Sessile bacteria, Planktonic bacteria
Sessile bacteria

Microorganisms attached to surfaces within a biofilm. They are the population most directly responsible for microbially influenced corrosion, and they are sampled by scraping or swabbing surfaces rather than from bulk fluid.

Related: Planktonic bacteria, Microbially influenced corrosion (MIC), Biofilm
Planktonic bacteria

Free-floating microorganisms suspended in the bulk fluid. Their counts indicate the general microbial load of the water but do not reliably represent the attached population causing corrosion on pipe walls.

Related: Sessile bacteria, Biofilm, Microbially influenced corrosion (MIC)
Biofilm

A structured community of microorganisms and their excretory products adhering to a surface. It creates localized chemistry differences and shelters cells from biocides, making it a common site for under-deposit pitting.

Related: Sessile bacteria, Under-deposit corrosion, Biocide treatment
Erosion-corrosion

Accelerated metal loss where flowing fluid or entrained solids continually remove protective films or corrosion products. Attack concentrates at changes in direction, welds, and areas of high local velocity or turbulence.

Related: Flow regime, Critical velocity, Impingement
Flow regime

The pattern in which multiphase fluids travel through a pipe, such as stratified, slug, annular, or dispersed flow. The regime controls where water wets the wall and where shear stresses promote or remove protective films.

Related: Water wetting, Erosion-corrosion, Critical velocity
Water wetting

The condition in which an aqueous phase contacts and continuously wets the internal pipe surface. Corrosion requires water wetting, so understanding when and where it occurs is central to predicting internal attack.

Related: Flow regime, Partial pressure of CO2, Oil wetting
Partial pressure of CO2

The fraction of carbon dioxide in a gas multiplied by total system pressure, expressed in pressure units. It is a common screening parameter for estimating the corrosivity of wet hydrocarbon service.

Related: Sweet corrosion (CO2 corrosion), Water wetting, Corrosion inhibitor
Under-deposit corrosion

Localized attack that occurs beneath accumulated solids, scale, or corrosion products. The deposit shields the surface and creates a differential environment that concentrates attack into deep pits.

Related: Biofilm, Mesa attack, Pitting corrosion
Mesa attack

A form of localized CO2 corrosion in which flat-topped, table-like plateaus of metal remain while surrounding areas are thinned. It is associated with partially protective iron carbonate films breaking down locally.

Related: Under-deposit corrosion, Iron carbonate scale, Pitting corrosion
Iron carbonate scale

A corrosion product film that can form on steel in CO2-containing water and, when dense and continuous, slows further metal loss. It becomes less protective at high flow, low pH, or when it is disrupted.

Related: Sweet corrosion (CO2 corrosion), Mesa attack, Scale inhibitor
Pitting corrosion

Localized corrosion that penetrates deeply over a small area while the surrounding surface remains largely intact. It is difficult to detect by general wall-loss averages and is a frequent cause of unexpected leaks.

Related: Under-deposit corrosion, Microbially influenced corrosion (MIC), Corrosion coupon
Galvanic corrosion

Accelerated attack that occurs when two dissimilar metals are electrically connected in an electrolyte, causing the more active metal to corrode faster. It is a concern at transitions between different pipe materials or weld overlays.

Related: Corrosion potential, Reference electrode, Cathodic protection
Sulfide stress cracking (SSC)

Brittle cracking of high-strength steels under the combined action of tensile stress and aqueous hydrogen sulfide. It is a safety-critical failure mode addressed by material hardness limits and qualification standards.

Related: Sour corrosion (H2S corrosion), Hydrogen-induced cracking, NACE MR0175 / ISO 15156
Hydrogen-induced cracking (HIC)

Stepwise internal cracking caused by hydrogen atoms diffusing into steel and recombining at inclusions or laminations. It is associated with wet sour service and evaluated by standardized laboratory testing.

Related: Sulfide stress cracking (SSC), Sour corrosion (H2S corrosion), NACE MR0175 / ISO 15156
NACE MR0175 / ISO 15156

The standard specifying materials and environmental limits for service in oil and gas production containing hydrogen sulfide. It defines acceptable steels, hardness limits, and qualification requirements for sour service.

Related: Sulfide stress cracking (SSC), Hydrogen-induced cracking (HIC), Corrosion-resistant alloy
Corrosion-resistant alloy (CRA)

A metallic material such as a stainless steel, duplex, or nickel-based alloy selected for its ability to resist a specific corrosive environment. Selection depends on chloride level, temperature, pH, and partial pressures of acid gases.

Related: NACE MR0175 / ISO 15156, Pitting resistance equivalent number (PREN), Internal corrosion direct assessment (ICDA)
Pitting resistance equivalent number (PREN)

A calculated index based mainly on chromium, molybdenum, and nitrogen content used to rank the pitting resistance of stainless and similar alloys. It helps compare candidate alloys against expected chloride and temperature conditions.

Related: Corrosion-resistant alloy (CRA), Chloride stress corrosion cracking, Pitting corrosion
Chloride stress corrosion cracking

Cracking of susceptible alloys, particularly austenitic stainless steels, under the combined action of tensile stress, chlorides, and elevated temperature. It is a risk when choosing alloy piping for hot chloride-bearing service.

Related: Corrosion-resistant alloy (CRA), Pitting resistance equivalent number (PREN), Sulfide stress cracking (SSC)
Oxygen corrosion

Metal loss caused by dissolved oxygen in water, producing rapid and often localized attack. Oxygen ingress is a major concern in water injection, hydrotest, and stagnant systems and is controlled by deaeration and oxygen scavengers.

Related: Oxygen scavenger, Pitting corrosion, Water injection system
Corrosion inhibitor

A chemical added continuously or in batches that adsorbs onto metal surfaces to slow corrosion. Effectiveness depends on correct dosage, good mixing, adequate contact time, and reaching all wetted surfaces.

Related: Inhibitor residual, Parting (film persistency) test, Biocide treatment
Inhibitor residual

The measured concentration of active corrosion inhibitor remaining in the produced water, used as an indicator that target dosage is being maintained. It does not by itself prove that the film is protecting the pipe.

Related: Corrosion inhibitor, Corrosion coupon, Key performance indicator
Biocide treatment

Chemical dosing intended to kill or suppress microorganisms in a system, often applied in batch and alternating between products to limit resistance. It is combined with cleaning to remove biofilms that shield sessile bacteria.

Related: Biofilm, Sulfate-reducing bacteria (SRB), Pigging program
Oxygen scavenger

A chemical such as a sulfite or bisulfite compound dosed to remove dissolved oxygen from water. It supports mechanical deaeration and protects injection and closed-loop systems from oxygen-driven corrosion.

Related: Oxygen corrosion, Water injection system, Corrosion inhibitor
Pigging program

A planned schedule of pipeline pig runs to remove liquids, solids, and deposits or to distribute inhibitor films. Regular pigging reduces under-deposit attack and stagnant water accumulation.

Related: Under-deposit corrosion, Biocide treatment, Slug (batch) treatment
Slug (batch) treatment

Intermittent injection of a concentrated chemical or liquid slug to coat pipe walls or displace fluids in low-flow lines. It is used where continuous injection is impractical or where film persistence is required.

Related: Corrosion inhibitor, Pigging program, Parting (film persistency) test
Corrosion coupon

A small specimen of known material and weight installed in a pipeline or vessel and later retrieved to measure metal loss and inspect attack morphology. Coupons provide direct evidence of corrosion rate at their location.

Related: Corrosion rate, Electrical resistance probe, Pitting corrosion
Electrical resistance (ER) probe

An instrument that infers metal loss from the increase in electrical resistance of a thin exposed element as it corrodes. It gives near-continuous trend data but is less sensitive to localized pitting than other methods.

Related: Corrosion coupon, Linear polarization resistance (LPR), Corrosion rate
Linear polarization resistance (LPR)

An electrochemical technique that estimates instantaneous corrosion rate from the current response to a small applied potential change. It works well in conductive aqueous systems and responds quickly to changes in treatment or conditions.

Related: Electrical resistance (ER) probe, Corrosion rate, Corrosion potential
Corrosion rate

The speed at which metal is lost, commonly expressed in millimeters per year or mils per year. It is compared against a target or allowance to decide whether mitigation or inspection changes are needed.

Related: Corrosion coupon, Remaining wall thickness, Key performance indicator
Corrosion potential

The electrical potential of a metal surface relative to a reference electrode in an electrolyte. It indicates corrosion tendency and is used in cathodic protection and electrochemical monitoring.

Related: Reference electrode, Linear polarization resistance (LPR), Cathodic protection
Reference electrode

A stable half-cell, such as silver/silver chloride or copper/copper sulfate, used as a benchmark when measuring pipe-to-electrolyte potentials. Its type must be stated because readings differ between references.

Related: Corrosion potential, Cathodic protection, Galvanic corrosion
Cathodic protection

A technique that applies an external current or sacrificial anode to shift a metal's potential to a less corrosive range. It is used for tanks, buried lines, and internal surfaces of water-handling equipment.

Related: Corrosion potential, Reference electrode, Galvanic corrosion
In-line inspection (ILI)

A pipeline survey using instrumented tools, such as magnetic flux leakage or ultrasonic wall-thickness tools, to detect and size metal loss. Results feed remaining-life calculations and integrity repair decisions.

Related: Remaining wall thickness, Internal corrosion direct assessment (ICDA), Integrity management plan
Internal corrosion direct assessment (ICDA)

A structured process that predicts where internal corrosion is most likely, then uses excavation and nondestructive examination at those locations to verify pipeline integrity where in-line inspection is not feasible.

Related: In-line inspection (ILI), Remaining wall thickness, Integrity management plan
Remaining wall thickness

The current pipe wall thickness after metal loss has occurred, determined by inspection or calculated from measured rates. It is compared with a required minimum to judge fitness for continued service.

Related: Corrosion rate, In-line inspection (ILI), Fitness-for-service assessment
Fitness-for-service assessment

An engineering evaluation of whether a component with known flaws or wall loss can safely continue operating under its intended conditions. It may set operating limits, reinspection intervals, or repair requirements.

Related: Remaining wall thickness, Root cause analysis, Integrity management plan
Root cause analysis

A structured investigation to determine the underlying physical, chemical, and operational reasons a failure occurred, rather than only the immediate mechanism. Findings drive corrective actions that prevent recurrence.

Related: Failure analysis, Fitness-for-service assessment, Management of change
Failure analysis

The technical examination of a failed component using visual, metallurgical, and chemical methods to identify the corrosion mechanism and contributing conditions. It supplies evidence that supports root cause conclusions.

Related: Root cause analysis, Pitting corrosion, Under-deposit corrosion
Key performance indicator

A measurable value, such as corrosion rate, inhibitor availability, or inspection completion, used to judge whether an integrity program is achieving its objectives. Indicators should be reviewed periodically and acted upon.

Related: Corrosion rate, Inhibitor residual, Management review
Management review

A scheduled, documented evaluation by responsible management of program performance, risks, and improvement actions. It confirms that corrosion control remains effective as conditions, personnel, and regulations change.

Related: Key performance indicator, Management of change, Integrity management plan
Management of change

A formal process for evaluating and approving changes to equipment, chemicals, operating conditions, or procedures before implementation. It ensures that corrosion risks and control measures are reassessed when something changes.

Related: Management review, Root cause analysis, Integrity management plan
Integrity management plan

A documented framework describing threats, assessment methods, mitigation activities, and review cycles for maintaining the mechanical integrity of equipment. It ties monitoring data and inspection results to decisions and records.

Related: In-line inspection (ILI), Fitness-for-service assessment, Management review
Hydrogen sulfide (H2S) hazard

A toxic, flammable gas that can deaden the sense of smell at higher concentrations and cause rapid incapacitation. Field work requires gas detection, respiratory protection, and rescue planning before entry or hot work.

Related: Confined space entry, Sour corrosion (H2S corrosion), Safety instrumented system
Confined space entry

Entering an enclosed or poorly ventilated area such as a tank or vessel, which requires atmospheric testing, permits, ventilation, attendants, and rescue provisions. Internal corrosion work frequently involves such entries.

Related: Hydrogen sulfide (H2S) hazard, Lockout/tagout, Safety instrumented system
Lockout/tagout

A procedure that isolates and secures energy sources before maintenance or inspection work begins. It prevents unexpected startup or release of stored energy while personnel are working on equipment.

Related: Confined space entry, Safety instrumented system
Safety instrumented system

An independent control system designed to bring a process to a safe state when predefined conditions are exceeded. It is applied where corrosion-driven loss of containment could create major safety consequences.

Related: Hydrogen sulfide (H2S) hazard, Lockout/tagout, Integrity management plan
Record retention requirement

The defined period and format for keeping monitoring, inspection, treatment, and compliance records so they remain retrievable and defensible. Retention periods are set by regulation, contract, and company policy.

Related: Management review, Integrity management plan, Regulatory compliance audit
Regulatory compliance audit

A structured review that checks whether corrosion control activities, documentation, and reporting meet applicable legal and regulatory requirements. Findings are tracked to closure with assigned responsibility and dates.

Related: Record retention requirement, Management review, Integrity management plan