AMPP ICS study materials
AMPP ICS study resources

AMPP ICS study guide

AMPP ICS · Work through your exam, one topic at a time.

The AMPP Internal Corrosion Specialist (ICS) certification is a credential confirming that a holder possesses the knowledge, skills, and abilities to competently manage and/or supervise the design, implementation, and evaluation of internal corrosion programs, regardless of industry. It is aimed at experienced professionals who already hold an active Senior Internal Corrosion Technologist certification and have completed the Ethics for the Corrosion Professional course (or equivalent training). The AMPP ICS study guide has 10 sections and about 2,295 words.

01

Internal Corrosion Mechanisms

Internal corrosion is an electrochemical process on the wetted surface of pipe or equipment. You must be able to name the mechanism, describe the anodic and cathodic reactions, and identify the controlling variable.

318 words, about 2 min
02

Environmental Variables and Operating Conditions

Internal corrosion is driven by the interaction of chemistry, physical conditions, and operating practice. Candidates must know which variables matter and how each shifts risk: Water chemistry: pH, dissolved CO2 and H2S partial pressures, chlorides, oxygen, and organic acids.

303 words, about 2 min
03

Hazards, Risks, and Personnel Safety in Field Activities

Internal corrosion work involves field activities that carry their own hazards. You must connect corrosion-control tasks to safety hazards and to the hierarchy of controls.

251 words, about 1 min
04

Corrosion Data Trends, Identification, and Verification

You must read corrosion data as a trend, not a snapshot. Key concepts: Data types: inspection (UT, MFL, visual), monitoring (coupons, ER/LPR probes, sampling), and process data (flow, pressure, temperature).

229 words, about 1 min
05

Mitigation Strategy Selection by Environment and Material

Mitigation must match the mechanism, the environment, and the material. Candidates must know the main options and their limits: Chemical inhibition: film-forming inhibitors for CO2/H2S; biocides for MIC; oxygen scavengers for oxygen ingress.

243 words, about 1 min
06

Alternative Design and Monitoring Options

When conventional mitigation is impractical, alternative design and monitoring options apply. Candidates must know the options and their trade-offs: Design alternatives: corrosion allowance, material upgrade, internal coating, chemical injection points, pigging facilities, and layout changes to avoid stagnant zones.

212 words, about 1 min
07

Failure Analysis and Root Cause Support

Failure analysis connects the failure to the mechanism and to the program gap. Candidates must know the steps: 1.

215 words, about 1 min
08

Design, Implementation, and Management of Corrosion Control Programs

A corrosion control program is a documented, managed cycle: design, implement, monitor, review, and improve. Candidates must know the elements: Design: risk assessment, mitigation selection, monitoring plan, and acceptance criteria.

187 words, under 1 min
09

Management of Corrosion Data, Assessment, Recommendations, and Implementation

Data management turns raw measurements into decisions. Candidates must know: Data governance: collection standards, calibration, storage, and access.

166 words, under 1 min
10

Monitoring, Mitigation, Records, and Legal/Regulatory Compliance

The final domain ties monitoring and mitigation to records and compliance. Candidates must know: Monitoring programs: frequency, methods, and acceptance criteria.