AR Electrician · Get comfortable with the vocabulary.

Ohm's Law

The rule stating that in a resistive direct-current circuit, voltage equals current multiplied by resistance. Knowing any two of the three values lets you calculate the third.

Related: Voltage Drop, Impedance
Impedance

The total opposition an alternating-current circuit offers to current flow, combining resistance with inductive and capacitive reactance. It is measured in ohms and sets the current for a given applied voltage.

Related: Power Factor, Ohm's Law
Power Factor

The ratio of true power in watts to apparent power in volt-amperes in an alternating-current circuit. A value below one means part of the current performs no useful work.

Related: Impedance
Voltage Drop

The reduction in voltage along circuit conductors caused by their resistance and the current flowing through them. Excessive drop leaves equipment running below rated voltage and wastes energy as heat.

Related: Ohm's Law, Ampacity
Continuous Load

A load whose maximum current is expected to continue for three hours or longer. Conductors and overcurrent devices serving it are generally sized at 125 percent of that current.

Related: Branch Circuit, Demand Factor
Demand Factor

The ratio of the maximum demand of a system, or part of it, to the total connected load. It lets designers size service and feeder equipment smaller than the sum of every load.

Related: Load Calculation, Continuous Load
Load Calculation

A prescribed method of totaling branch-circuit, feeder, and service loads using code volt-ampere values, demand factors, and allowances to determine the capacity an installation requires.

Related: Demand Factor, Continuous Load
Ampacity

The maximum current, in amperes, that a conductor can carry continuously under its conditions of use without exceeding its insulation temperature rating.

Related: Conductor Derating, Temperature Rating
Conductor Derating

Reducing a conductor's allowable ampacity to account for conditions of use, such as more than three current-carrying conductors in a raceway or a higher ambient temperature.

Related: Ampacity, Raceway Fill, Temperature Rating
Temperature Rating

The maximum continuous insulation temperature a conductor is listed for, such as 60, 75, or 90 degrees Celsius. Termination ratings often limit how much of it may be used for ampacity.

Related: Ampacity, Conductor Derating
Circular Mil

A unit of cross-sectional area equal to the area of a circle one-thousandth of an inch in diameter, used to state conductor sizes and to compute resistance.

Related: Ampacity
Box Fill

The total volume, in cubic inches, that conductors, devices, fittings, and grounding conductors occupy inside an enclosure. It must not exceed the box's marked capacity.

Related: Raceway Fill
Raceway Fill

The percentage of a raceway's internal cross-sectional area taken up by conductors. Keeping it within limits controls pulling tension and heat buildup inside the raceway.

Related: Conductor Derating, Box Fill
Service Drop

The overhead conductors the utility runs from its last pole or transformer to the service point at the building, ending where the customer's wiring begins.

Related: Service Lateral, Feeder
Service Lateral

The underground conductors run from the utility supply to the service point of a building, ending where the customer's service-entrance conductors begin.

Related: Service Drop, Feeder
Feeder

All circuit conductors between the service equipment, or a separately derived source, and the final branch-circuit overcurrent device that protects the load.

Related: Branch Circuit, Overcurrent Protective Device
Branch Circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlets or utilization equipment that the circuit supplies.

Related: Feeder, Continuous Load
Multiwire Branch Circuit

A branch circuit with two or more ungrounded conductors that have a voltage between them and share one neutral. All ungrounded conductors must be opened together.

Related: Branch Circuit, Grounded Conductor
Grounded Conductor

A circuit conductor intentionally connected to earth at the source. It carries return current during normal operation and is identified by white or gray insulation.

Related: Main Bonding Jumper, Equipment Grounding Conductor
Equipment Grounding Conductor

The conductor that connects normally non-current-carrying metal parts of equipment to the grounding system, giving fault current a low-impedance path back to the source.

Related: Grounding Electrode, Main Bonding Jumper
Grounding Electrode

A rod, pipe, plate, or other approved object in direct contact with the earth, used as the connection point for a building's grounding electrode system.

Related: Equipment Grounding Conductor, Main Bonding Jumper
Main Bonding Jumper

The conductor or screw that connects the grounded circuit conductor to the equipment grounding conductor at the service, creating the single point where the system is grounded.

Related: Grounded Conductor, Separately Derived System
Separately Derived System

A wiring system whose power comes from a transformer, generator, or converter with no direct connection to the supply conductors, so it must be grounded and bonded on its own.

Related: Main Bonding Jumper, Grounding Electrode
Overcurrent Protective Device

A fuse or circuit breaker that opens a circuit automatically when current exceeds a chosen value for a chosen time, protecting conductors from overheating.

Related: Interrupting Rating, Feeder
Available Fault Current

The maximum short-circuit current a supply can deliver at a given point in the system. Equipment installed there must have an interrupting rating at least that high.

Related: Interrupting Rating, Series-Rated System
Interrupting Rating

The highest fault current a device can safely interrupt at its rated voltage without being damaged or failing dangerously. It is marked on the device and must meet or exceed the available fault current.

Related: Available Fault Current, Series-Rated System
Series-Rated System

A tested combination in which a downstream breaker with a lower interrupting rating is backed up by an upstream current-limiting device, allowing the pair's higher rating to be used.

Related: Interrupting Rating, Available Fault Current
Selective Coordination

Choosing overcurrent device ratings and settings so that only the device closest to a fault opens, keeping upstream devices closed and the rest of the system energized.

Related: Overcurrent Protective Device
Motor Full-Load Current

The current a motor draws at its rated load and voltage, taken from code tables and used to size branch-circuit conductors and protective devices.

Related: Motor Overload Protection, Motor Disconnecting Means
Motor Overload Protection

A sensing device that interrupts the motor on sustained excess current, protecting the windings from overheating while allowing normal starting current to pass.

Related: Motor Full-Load Current, Motor Disconnecting Means
Motor Disconnecting Means

A switch or breaker, generally within sight of the motor and controller, that opens all ungrounded conductors so the motor can be worked on safely.

Related: Motor Overload Protection
Ground-Fault Circuit Interrupter

A device that compares current leaving and returning on a circuit and opens it quickly when a small imbalance shows current is leaking to ground.

Related: Arc-Fault Circuit Interrupter
Arc-Fault Circuit Interrupter

A device that watches the circuit waveform for the pattern of an arcing fault and opens the circuit, reducing the chance of fire from damaged or deteriorated wiring.

Related: Ground-Fault Circuit Interrupter
Hazardous (Classified) Location

An area where flammable gases, vapors, dusts, or fibers may be present in amounts that could ignite, requiring specially designed equipment and wiring methods.

Related: Listed
Working Space

The clear area required in front of electrical equipment, kept free of obstructions so a person can work safely. Its depth depends on voltage and surrounding conditions.

Related: Arc Flash, Lockout/Tagout
Arc Flash

A rapid release of energy from an arcing fault that produces intense heat, light, and pressure capable of burning or injuring workers near energized equipment.

Related: Working Space, Lockout/Tagout
Lockout/Tagout

A procedure in which equipment is de-energized, a personal lock and tag are applied, and the absence of voltage is verified before work begins.

Related: Arc Flash, Working Space
Listed

Equipment or material shown in a list published by a nationally recognized testing laboratory, meaning it has been tested and found to meet a recognized standard for its intended use.

Related: Hazardous (Classified) Location