Arkansas Plumbing Law, Rules, and Licensing Requirements

  • A master plumber may obtain plumbing permits, contract for plumbing work, and supervise others; a journeyman plumber performs plumbing work only under a master's direction.

  • Apprentices must be registered with the state board and work under direct supervision of a licensed plumber while accumulating the required work hours.

  • The Arkansas State Plumbing Code adopts the International Plumbing Code as the base document, with state amendments that control where the two differ.

  • Plumbing permits are issued by the local authority having jurisdiction (AHJ); where no local plumbing program exists, the Arkansas Department of Health administers permits and inspections.

  • A license is required before performing plumbing work for compensation; owner exemptions generally apply only to owner-occupied single-family dwellings.

  • A license must be renewed before its expiration date; working on an expired license is a violation subject to civil penalties.

  • Revised plans that affect code compliance must be submitted to the AHJ and approved before the changed work is installed.

Quick reference

General Regulations, Permits, and Code Administration

  • A permit is required before installing, altering, replacing, or relocating a plumbing system; ordinary minor repairs such as replacing a faucet washer are exempt.

  • The permit holder must request rough-in inspection before piping is covered and final inspection after fixtures are set and tested.

  • Drainage and vent systems are tested with a 10-foot (3 m) hydrostatic head of water, or with 5 psi of air held for 15 minutes.

  • Water distribution piping is tested with potable water at the working pressure for at least 15 minutes and must show no leakage or pressure drop.

  • A certificate of occupancy or use is withheld until the plumbing final inspection passes.

  • The code official may accept alternative materials, methods, or designs when they comply with the intent of the code and the approval is documented in writing.

  • Construction documents must show fixture locations, pipe sizes, and riser diagrams before a plumbing permit is issued.

Quick reference

Plumbing Mathematics, Sizing, and Isometric Analysis

  • One water-supply fixture unit represents about 1 gpm of demand; one drainage fixture unit (DFU) approximates the drainage load of a lavatory.

  • Common DFU values: water closet 3, lavatory 1, bathtub or shower 2, kitchen sink 2, floor drain 2, washing machine 2.

  • Slope rule: horizontal drainage pipe 2½ inches and smaller at ¼ inch per foot; 3-inch through 6-inch pipe at ⅛ inch per foot.

  • Grade in percent = rise ÷ run × 100; ¼ inch per foot equals approximately 2 percent slope.

  • Travel of a 45-degree offset equals the offset multiplied by 1.414; two 45-degree bends and a 90-degree change are solved the same way.

  • Pressure conversion: psi × 2.31 = feet of water column head, so 1 psi is about 2.31 ft of head.

  • Gallons of water in a pipe = 0.0408 × (inside diameter in inches)² × length in feet.

  • Developed length includes the measured run plus an allowance for fittings; it is used with fixture units to size water supply piping.

Quick reference

Water Supply and Distribution Systems

  • Residual flowing pressure must be at least 8 psi at fixtures generally, and at least 15 psi at flushometer valves.

  • Design velocity limits are about 8 fps in cold-water piping and 5 fps in hot-water piping to control noise and erosion.

  • A pressure-reducing valve is required where static pressure exceeds 80 psi; a thermal expansion tank is required on a closed system.

  • Minimum building water supply size is typically ¾ inch for a single-family dwelling served by a ¾-inch meter.

  • Water service pipe must be buried below the local frost depth and at least 12 inches deep where frost is not a design factor.

  • Water hammer arrestors are installed near quick-closing valves such as flushometers and solenoid valves.

  • Longest-length and available-pressure methods determine pipe size from the meter or source to the farthest fixture.

  • A backflow preventer is required wherever a piping connection could create a cross-connection with the potable supply.

Quick reference

Plumbing Fixtures, Faucets, and Fixture Fittings

  • Federal flow limits: water closet 1.6 gal per flush, urinal 1.0 gal per flush, showerhead 2.5 gpm at 80 psi, lavatory and kitchen faucet 2.2 gpm.

  • A water closet requires at least 15 inches from its centerline to a sidewall and at least 30 inches of clear width.

  • Accessible lavatory rims must be no higher than 34 inches above the finished floor, with knee and toe clearance below.

  • Every fixture must be trapped except fixtures with an integral trap; the trap must remain accessible for cleaning.

  • Fixture tailpieces must extend at least 4 inches below the fixture, and slip joints or unions must be accessible.

  • Faucets and fittings must be installed so hot is on the left and cold on the right, matching the identification on the trim.

  • Fixtures must be set level and secure, with supply stops installed on the fixture supply so the fixture can be serviced independently.

Quick reference

Sanitary Drainage Systems

  • Horizontal drainage pipe is installed at a uniform slope: ¼ inch per foot for 2½-inch and smaller, ⅛ inch per foot for 3- through 6-inch.

  • Cleanouts are required at the base of each stack, at horizontal changes of 45 degrees or more, and at intervals not exceeding 100 feet.

  • Drainage pipe size may not decrease in the direction of flow.

  • A vertical change of 45 degrees or more in a horizontal drain requires a long-turn fitting or two 45-degree bends.

  • Trap arm length limits: 1¼ inch - 5 ft, 1½ inch - 6 ft, 2 inch - 8 ft, 3 inch - 12 ft.

  • The building drain carries waste to the building sewer; the building sewer begins about 2 feet outside the building wall.

  • A backwater valve is required where fixtures are below the level of the street or where the sewer can surcharge.

  • Drainage piping installed in or under a slab must be protected against shear and supported at code-required intervals.

Quick reference

Vents and Venting Systems

  • Every trap must be vented; a vent may not be smaller than 1¼ inch nor less than half the size of the drain it serves.

  • Vent terminals must extend at least 6 inches above the roof and must be at least 10 feet horizontally from, or 3 feet above, windows, doors, and air intakes.

  • Each vent stack must extend to the outdoors; air admittance valves are allowed only where the code permits and must remain accessible.

  • Wet venting lets one fixture drain vent another fixture, but only where both fixtures are on the same floor and the sizing rules are met.

  • Common vents require the fixtures to be on the same floor and connected at the same level, with the vent sized to the largest drain served.

  • A horizontal vent must rise at least 6 inches above the flood-level rim of the fixture before any offset.

  • The connection between a vent and a drain must be taken above the flood-level rim of the fixture served.

Quick reference

Traps, Interceptors, and Backflow Prevention

  • Trap seals must be at least 2 inches and not more than 4 inches deep, and each trap must be level and self-cleaning.

  • S-traps, drum traps (except where allowed), and double-trapping of a single fixture are prohibited.

  • Grease interceptors are required for food-service fixtures that discharge fats, oils, and grease into the drainage system.

  • An air gap is the only absolute backflow protection and is required for high-hazard connections such as a hose bibb feeding a chemical container through a direct connection.

  • A reduced pressure zone (RPZ) assembly protects against high hazard; a double check valve assembly protects against low hazard.

  • A pressure vacuum breaker protects against backsiphonage but not against backpressure.

  • Traps and cleanouts must be accessible, and each trap may serve only one fixture except where the code allows a combination.

Quick reference

Water Heaters and Temperature Control

  • A temperature and pressure (T&P) relief valve is typically set to open at 210°F and 150 psi, and its rating must match the heater's input.

  • The T&P discharge pipe must be the same size as the valve outlet, drain by gravity, and terminate 6 inches above the floor or outside the building.

  • Domestic hot water delivered to fixtures must not exceed 120°F unless a tempering or mixing valve limits the temperature.

  • A thermal expansion tank is required on a closed system protected by a backflow preventer or check valve.

  • A drain pan with a drain line is required where leakage from the heater could cause damage or where the heater is installed in an attic or ceiling space.

  • Gas-fired heaters require combustion air, proper venting, and a sediment trap on the gas supply line.

  • Relief valve discharge must not be trapped, plugged, or reduced in size, and the valve must not be relocated from the heater's designated opening.

Quick reference

Special Systems: Storm Drainage, Fuel Gas Piping, and Specialty Plumbing

  • Storm drainage must discharge to a storm sewer or other approved point of disposal and may never connect to the sanitary sewer.

  • Roof drain and leader sizing is based on the design rainfall rate and the tributary roof area in square feet.

  • Secondary (overflow) roof drains are required for large roofs and must be set higher than the primary drains.

  • Fuel gas piping is sized by the longest-length method using each appliance's Btu/h load and the allowable pressure drop.

  • Gas piping is pressure-tested with air at not less than 3 psi, or at the pressure specified by the code, for the required holding time.

  • A sediment trap and a listed shutoff valve must be installed ahead of each gas appliance.

  • Gas piping may not be concealed inside ducts, plenums, or chimneys.

  • A sewage ejector is required when plumbing fixtures are located below the level of the public sewer.