AR Plumber flashcards
AR Plumber · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Master plumber license
- Arkansas credential authorizing the holder to contract for plumbing work, obtain permits, and supervise other plumbers on the job.
- Journeyman plumber
- Licensed plumber who installs and repairs plumbing under a master plumber's supervision but who may not contract for plumbing work independently.
- Arkansas State Plumbing Code
- State plumbing regulation built on the International Plumbing Code with Arkansas amendments; it sets the installation standards enforced statewide.
- Plumbing permit
- Written authorization from the authority having jurisdiction that is required before installing, altering, or replacing plumbing; minor repairs are exempt.
- DWV hydrostatic test
- Drainage and vent systems are tested with a 10-foot head of water, or with 5 psi of air held for 15 minutes, to prove tightness.
- Final plumbing inspection
- Inspection performed after fixtures are set and systems tested; approval is required before the building can legally be occupied.
- Drainage fixture unit
- Measure of drainage load; one DFU approximates a lavatory's discharge while a tank-type water closet is rated at 3 DFU.
- Drainage slope rule
- Horizontal drains 2½ inches and smaller slope ¼ inch per foot; pipe from 3 through 6 inches slopes ⅛ inch per foot.
- 45-degree offset travel
- In an isometric layout, the diagonal travel of a 45-degree offset equals the offset distance multiplied by 1.414.
- Feet of head
- One psi equals about 2.31 feet of water column; multiply pressure in psi by 2.31 to convert it to head in feet.
- Residual pressure
- Flowing pressure remaining at a fixture; at least 8 psi is required generally and 15 psi at flushometer valves.
- Pressure-reducing valve
- Device installed when static water pressure exceeds 80 psi to protect fixtures, appliances, and piping from excessive pressure.
- Water hammer arrestor
- Air-charged device placed near quick-closing valves to absorb the shock wave created when flow stops suddenly.
- Developed length
- Total effective pipe length including fittings; used together with fixture units to size water supply piping.
- Water closet clearance
- A water closet needs at least 15 inches from its centerline to any sidewall and at least 30 inches of clear width.
- Accessible lavatory height
- An accessible lavatory rim must be no higher than 34 inches above the finished floor, with knee clearance beneath it.
- Fixture flow limits
- Federal maximums: 1.6 gallons per flush for water closets, 2.5 gpm for showerheads, and 2.2 gpm for faucets.
- Building drain
- Lowest piping of the drainage system inside the building; it receives waste and carries it to the building sewer.
- Cleanout
- Access opening in a drainage line for removing blockages; required at stack bases and at horizontal changes of 45 degrees or more.
- Backwater valve
- One-way valve on a drainage line that stops sewage from flowing backward into fixtures when the public sewer surcharges.
- Vent terminal
- Upper end of a vent stack; it must extend 6 inches above the roof and be kept away from windows and air intakes.
- Wet vent
- A vent that also serves as a drain for another fixture, permitted only when both fixtures are on the same floor.
- Air admittance valve
- One-way valve that admits air into a vent to equalize pressure; allowed only where the code permits and must stay accessible.
- Trap seal
- Depth of water in a trap that blocks sewer gas; it must be at least 2 inches and no more than 4 inches.
- Air gap
- Unobstructed vertical distance between a water outlet and the flood-level rim of a fixture; the most reliable backflow protection.
- Reduced pressure zone device
- Testable backflow preventer with two check valves and a relief valve, used to protect against high-hazard cross-connections.
- T&P relief valve
- Safety valve on a water heater that opens at excessive temperature or pressure, typically set at 210 degrees Fahrenheit or 150 psi.
- Thermal expansion tank
- Closed tank with an air charge that absorbs the volume of water expanding in a closed plumbing system as it heats.
- Water heater drain pan
- Watertight pan placed beneath a water heater where leakage could cause damage; it must be drained to an approved location.
- Secondary roof drain
- Backup roof drain set higher than the primary drain that provides an alternate flow path when the primary drain is blocked.
- Sediment trap
- Short downward leg of gas piping that catches dirt and moisture before it can reach an appliance's gas controls.
- Sewage ejector
- Pump and receiving basin that lift drainage from fixtures located below the level of the public sewer to a gravity drain.